Permit#: K2304-005 SCOPE OF WORK: GENERAL NOTES: DESIGN CRITERIA: <br /> Site Address: 7800 Evergreen Way <br /> Applicant: Archer Construction Inc -- •MODIFY EXISTING OVERHEAD FIRE SPRINKLER SYSTEM TO ACCOMODATE NEW TENANT WALLS&CEILINGS •ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL ANDIOR FM APPROVED. •DESIGN AND TESTING BASED ON NFPA 13(2016)AND EVERETT CODES. <br /> Application Date: 04/06/2023 IN EXISTING PORTION OF BUILDING.EXTEND EXISTING WET PIPE AND DRY PIPE SYSTEMS TO PROTECT •JOINING OF PIPE AND FITTINGS,THREADED AND WELDED,SHALL BE IN •SHOWROOM-ORDINARY HAZARD(GROUP 1)-1511500'SQ.FT.-130 SQ.FT.MAXIMUM HEAD SPACING <br /> Description: Modify Existing Fire Sprinkler Systems �� �' NEW BUILDING ADDITION. ACCORDANCE WITH NFPA 013. WITH 15'MAXIMUM BETWEEN HEADS. <br /> ................... <br /> • •- •-.�--..�..1 ACCORDANCE WITH NFPA#13 HAZARD 1511500 SQ FT 15 X 15 MAX HEAD SPACIN <br /> • ,,,, ,,,,,,, ,,, �F.Awc�.�ea r t��, PIPE HANGER AND METHOD OF HANGING TO BE IN � OFFICE,BATHROOMS,ENTRY VESTIBULE,ETC.-LIGHT HAZA G <br /> Review Status: 1stReviewbyCityBPeerReviewers ""_"`�� '••, "'.�— CLARIFICATIONS: PIPING SHALL BE IN ACCORDANCE WITH NFPA#13.AC WITH SMALL ROOM RULE ALLOWED WHEREAPPLICABLE. <br /> Review Date: 04/10/2023 ►' / •ABOVE CEILING AREAS WITH 12"TAS SPACED 2FT O.C.-LIGHT HAZARD-OBSTRUCTED CONSTRUCTION- <br /> .... a II �-i1 / ALL AREAS PROTECTED BYAWET SYSTEM MUST BE MAINTAINEDATAMINIMUM OF 40°F(BY OTHERS) <br /> 4 n, -� `�� IN ORDER TO PREVENT THE PIPE FROM FREEZING. 130 SQ.FT.MAX HEAD SPACING,WITH 15 FT MAXIMUM BETWEEN HEADS. <br /> .: _` � •ABOVE CEILING AREAS WITH 2x WOOD TRUSSES SPACED 2FT 0.C.8 ROOF SLOPE 4:120RGREATER- <br /> EVERETT ;rf. t -=r'� / EXCLUSIONS: LIGHT HAZARD-120 SQ.FT.MAX HEAD SPACING,WITH 15 FT MAX.BETWEEN HEADS PARALLEL TO SLOPE. <br /> / &10 FT MAX.BETWEEN HEADS PERPENDICULAR TO SLOPE.ALSO MUST FOLLOW FIG.8.6.4.1.4. <br /> Everett Fire Dept.Permit Review / •ANY AND ALL UNDERGROUND PIPING EXCAVATION AND BURY. <br /> •ABOVE CEILING AREAS WITH DOUBLED-15' WOOD TRUSSES W12x4 TOP CHORD,SPACED G 4FT O.C. <br /> Status:Approved I EXISTING HYDRANT / •PAINTING AND CLEANINGIPREPARATION OF FIRE SPRINKLER PIPING. <br /> LIGHT HAZARD-UNOBSTRUCTED-15'X 15'MAX HEAD SPACING. <br /> •WEATHER PROOFING OF EXTERIOR PENETRATIONS. <br /> Reviewed By:KBrown - - --I__—L_1_J_ _1_1-J_-�_1--1_-J-V 1 •DOMESTIC MATERIALS. <br /> 04/10/2023 10:42:45 4\ <br /> AM p / •TESTING FOR AN REMOVAL OF HAZARDOUS MATERIALS. <br /> Q} / •CUTTING,PATCHING AND PAINTING OF STRUCTURE,FIRE PROOFING. <br /> / - / •CLEANING ANDIOR FINAL CLEANING OF TENANT SPACE DURING INSTALLATION PROCESS. BUILDING INFO: <br /> _ / •PROTECTION BELOW FRONT EXTERIOR OVERHANG. <br /> Or •WORK IN SHOP AREA OF MAIN BUILDING AND STANDALONE SHOP BUILDING. •PARCEL#=28050700300700 <br /> Q NEW / •SPECIALTY SYSTEMS(PROTECTION OF KITCHEN HOODS,EXHAUST DUCTS). •OWNER:LMJ ENTERPRISES LP,11845 NE 85TH ST,KIRKLAND,WA 98033 <br /> NEW CppR •REMOTE FDC,FIRE PUMP. <br /> (EI RETAIL AREA DEy ERV / OCCUPANCY=BUSINESS <br /> CHANGING TO PARTS / •FLOW TEST FEES. <br /> / •PIE FPE,FACTORY MUTUAL,OR INSURANCE STAMP OR APPROVAL. •COPER ST UCTURPE:III-B <br /> > E)2 STORYCE AREA / / •ANY AND ALL ELECTRICAL WORK. •Ss PER STRUCTURAL PLANS:1.343 <br /> NO NEW WORK IN / •BONDS,INSIST. <br /> THIS AREA / / <br /> / <br /> / T.O.NEW Paragraph 8.6.4.1.4.2 <br /> 1 in.to Row of Sprinklers required within 12 in. <br /> REMODELED 5 4 3 2 1 SHOWROOM 12 in. h°n r lry and between I in.and 12 E, <br /> EXISTINGWET&DRYS RISERS, <br /> / / PARAPET sown bom he bottom m the top cnom member <br /> WALL WALL <br /> INDICATOR NEW PIN SHOWROOM /EW 22 Additional sprinklers sPacer�&WALL POST <br /> I &HEADS IN THIS <br /> ( TOTALBUILDING / <br /> T.O.SERVICE 1 in. <br /> along slope as required <br /> NO NEW WORK IN ) F4,501 S I�f� / — — — 1 in. <br /> z4,5D1s,G.FT. sI_oPE o.s:12 — _ _ _ _ _ DRIVE PARAPET }� b12in. b12In. Paragraph 5111(i.4.3 <br /> 7 - _ _ 2P'-7�" 5#4.1..3 <br /> .") NEW SERVICE / / "�/' _ _�./ minimu� <br /> DRIVE / / — <br /> I / <br /> / EXISTIN ED <br /> � I Ied space <br /> ceirng m space I»IDw <br /> / // RO Al Roi orrlcein combustible <br /> (E)DCVA IN VAULT / NO SPRINKLERS <br /> _ _ _ COVERING <br /> T- T — - — _ BELOW *The 5 h min mum din - ored from me <br /> 1 T T T t` •'f- I I OVERHANG. III iMersedion of the uppe d 1,uss moms <br /> 8 1 --�B STORAGE OF or the wood ravers and ceiling joists. <br /> T. .... -" <br /> • B 6 COMBUSTIBLES I <br /> Or <br /> NOT ALLOWED SLAB NEW <br /> 1 BENEATH. T.O. <br /> H W RCOIV) }� FIGURE 8.6.4.1.4 <br /> - / - SEE STRUCTURAL <br /> DRAWINGS FOR <br /> / SLAB CONNECTION <br /> i <br /> REFERENCE FIRE SITE PLAN -40 0 40 80 160 <br /> SCALE:1"=W-0- BUILDING SECTION 'B' -10 0 10 20 40 <br /> SCALE:1"=40'-0" <br /> SCALE:1/8"=1'-0" <br /> SCALE:1/8"=1'-0" <br /> 0 Y,n .1 <br /> NEW ROOF ASSEMBLY <br /> •60 MIL.TPO ROOF MEMBRANE(WHITE) SHOWROOM ROOF ASSEMBLY NEW SERNCE DRIVE WALL ASSEMBLY • °•.� <br /> •DECKING(PER STRUCTURAL) •60 MIL.TPO ROOF MEMBRANE(WHITE) •EXTERIOR WALL FINISH PER C - <br /> •JOISTS(PER STRUCTURAL) •5/8"RECOVERY BOARD ELEVATIONS rwm N" SITE 4Y4,, e + ` _ <br /> •5181 GWB SHEATHING RIGID INSULATION(R-38)-MECHANICALLY FASTENED •FURRING CHANNEL$A$REQUIRED FOR jS q <br /> •STUCCO FINISH TO MATCH ADJACENT WALLS •ROOF DECK(PER STRUCTURAL METAL PANELS(WHERE APPLICABLE) <br /> •ROOF STRUCTURE(PER STRUCTURAL) •CONTINUOUS RIGID -SERVIC DRIVE ROOF ASSEMBLY <br /> K T_" <br /> G F E D C B "--r' <br /> INSULATION •60 MIL.TPO ROOF MEMBRANE(WHITE) <br /> .VVRB •5/8"RECOVERY BOARD <br /> •SHEATHING PER STRUCT. •RIGID INSULATION(R-38)-MECHANICALLY FASTENED <br /> •BATT INSULATION(R-21)� •ROOF DECK(PER STRUCTURAL _ c. ! a., Q o Q <br /> •VAPOR BARRIER •ROOF STRUCTURE(PER STRUCTURAL) <br /> •5/8"TYPE'X'GWB 9 <br /> •FINISH PER PLAN A T.Q.NEW <br /> 3 SHOWROOM P. se„d0 Qn'Keri<,;,,u..rn r..-... V <br /> Aso1 A5.o1 As11 Aso1 PAR22EO _ 9 8 PQo V <br /> I —9 p- <br /> T.O.SERVICE <br /> DRIVE PARAO 7 Y w om �y p aB <br /> G <br /> at, <br /> 0 Q C V <br /> T.O.NEW CAR <br /> - T4 — — — DELIVERY a-m_9 <br /> I 16-0" 0 <br /> it w <br /> I I I wr <br /> T.O.SLAB NEW <br /> SHOWROOMVICINITY MAP <br /> 0• <br /> SCALE:NTS <br /> m <br /> SHOWROOM SLAB ON GRADE ASSEMBLY <br /> •FINISH PER PLAN ___________ _ ___ <br /> •REINFORCED CONCR TE SLAB(PER STRUCTURA) w"exlxorox a <br /> •15 MIL VAPOR BARRI ce"I"C",or COMPETENCY <br /> •COMPACTED CRUSH RAVEL(PER GEOTECHNIC REPORT) Theodore M.Queen"IxxLe"en ea <br /> r 4930-0205-C Level N <br /> BUILDING SECTION 'A' 10 0 10 zo ao Archer Construction,Inc. <br /> r Amber 219DR ; <br /> J_a e2 <br /> SCALE:1/8"=1'-0" SCALE:1/8"=V-0" ••-•-••---••---- <br /> WATER SUPPLY HYDRAULIC DESIGN INFORMATION HANGER ATTACHMENT ABBREVIATIONS SYMBOLS SPRINKLER SYMBOLS , <br /> STATIC 87PSI AREA HAZARD CLASSIFICATION TYPE DENSITY AREA SIZE COVERAGE PER SPRINKLER HOSE SYSTEM DEMAND A BEAM CLAMP CL CEWERIJNEOFPIPE *FF(CL)ABOVE FINISHED FLOOR SYM MAKE MODEL AMINO TYPE FINISH K PROJECT: Lee Johnson Hyundai of Everett FIRE SPRINKLER <br /> •FAC.THREAD TEMP CANOPY QTY PIPING PLAN <br /> RESIDUAL 28PSI B SIDE BEAM BRACKET CTS DILL TOSUIT *BB(CL)BOTTOM OFBEAM VICTAUIC V27 V2708 OR RECESSED SSP CHROME 5.6 Ur 15V CHRIREC T1 7802 Evergreen Way <br /> GPM FLOWING 21880M C EYE SOCKET FO FIELD ORDER *TB(CL EA)TOP OF BM Q ACTAUIC V27 V2704 OR SSU BRASS 5.6 Ur 211V WA 16 PERMIT ND: - <br /> DATE&TYE 1M9123 D NUT&PLATE WASHER WOW INSIDE FACE OF WALL *TS(CL)TOP OF STEEL/BOTTOM OF DECK G VICTAUIC V27 W704 OR SSU BRASS 5.6 Ur 20V WA 52 Everett, WA 98203 JOB - <br /> PER:MKEMENDIK E KWIK-BOLT OFOW OUTSIDE FACE OF WALL RIGID COUPLING IS MCTAIAIC V27 V2708 OR SSP BRASS 5.6 Ur 200• WA YO ARCHER. <br /> LOCATION:- F HIDI-P HAS NO AUTO SPRINGERS FLEXIBLE COUPLING ® GLOBE GL GL5635 OR DRY SLEEVE&SKIRT SSP CHROME 5.6 Ur 155° CHRISLV x WSCL#:ARCHEI*219DR DESIGNER: TEA M... <br /> CONTRACT W/: Foushee <br /> 7800 EVERGREEN WAY G SAMMY SIDEWINDER UNO UNLESS NOTED OTHERWISE / TYCO DS•3 TY5339 SR DRY ECOH DRY HIMCHROME 5.6 Ur 15V DEEPICHR 7 <br /> - H SAMMY SUPERSCREW CGJ CUT ON JOB FIRE SPRINKLER DIVISION SITE CONTACT: Chris Denchfield SCALE: Aa Nobtl <br /> NOTEs:- J COACH SCREW ROD 7855 S 206TH STREET, KENTI WA 98032 DATE: IR23 <br /> K COACH <br /> PHONE 253-872-7222 FAX 253-872-7277 PHONE: 425-466-9681 REVISED t7 FP 1 OF 3 <br /> T TRAPEZE TOTAL PROJECT AMPRINKLlRAM a 1. PLOTTED N <br />