6801 SEAWAY BLVD 2024 MCKESSON CORP Plans 2025-08-20
>
Address Records
>
SEAWAY BLVD
>
6801
>
MCKESSON CORP
>
Plans
>
6801 SEAWAY BLVD 2024 MCKESSON CORP Plans 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 9:26:22 AM
Creation date
8/20/2025 9:26:07 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
6801
Tenant Name
MCKESSON CORP
Permit
K2407-010
Year
2024
Notes
Adding 254 new sprinkler heads for T.I.
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCOPE OF WORK Permit#: K2407-010 <br /> 1. MODIFY EXISTING SPRINKLER SYSTEM TO ACCOMMODATE NEW TENANT IMPROVEMENT Site Address: 7007 Seaway BLVD <br /> WORK INCLUDING NEW WALLS AND CEILINGS. Applicant: Derek Strickland <br /> 2. EXISTING SYSTEM IS TO REMAIN OUTSIDE AREAS OF WORK. Application Date:0713012024 <br /> 3. EXISTING OVERHEAD PIPING, SPRINKLERS,AND HANGERS ABOVE NEW CEILINGS TO Description: Adding 254 new sprinkler heads for T.I. <br /> REMAIN. Review Date: 08/01/2024 <br /> 4. ALL NEW THREADED PIPING IS TO BE SCHEDULE 40 BLACK PIPE. <br /> EVERETT <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown HANGER LEGEND <br /> 08/01/2024 12:26:20 A "U" HOOK <br /> PM <br /> B COACH SCREW ROD <br /> D BM. CLAMP W "STRAP <br /> APPROVED E EYELET <br /> PUBLIC WORKS DEPARTMENT F FLUSH SHELL <br /> BY:THerman G CEILING FLANGE <br /> DATE:08/01/2024 H SIDE BEAM BRACKET <br /> CITY OF EVERETT REVIEWED FOR PERMIT K SHORT CLIP <br /> M ALL THREAD ROD <br /> IN TOGGLE NUT <br /> P POWDER DRIVEN STUD <br /> R EXPANSION BOLT <br /> TPO ROOFING SYSTEM T SAMMY XPRESS <br /> E OVER RIGID INSULATION B A D <br /> OVER 11/2" 20 GA METAL DECKING 12" w <br /> OVER METAL STRUCTURE 3/8" Y <br /> z <br /> APPROVAL REQUIRED <br /> CITY OF EVERETT <br /> METAL BAR JOISTS AT PEAK <br /> 30'-2" PER STRUCTURAL AT PE 30'-2" <br /> O ":iFMP RnilxG(r) J112 <br /> 212'286'S50' ti QM Soo' /1' <br /> —METAL COLUMNS FITTING LEGEND <br /> CONCRETE TILT WALL PANEL PER STRUCTURAL P PIPE LET <br /> SN GROOVVEE D SHAPED NIPPLE <br /> CONCRETE SLAB ON GRADE TSN THREADED SHAPED NIPPLE <br /> �` <br /> ADN ADJUSTABLE DROP NIPPLE <br /> FIG FLANGE <br /> RC REDUCING COUPLING <br /> 0 STRUCTURE TO CENTER <br /> / UNE OF PIPE IN INCHES <br /> r---o_____a/ 2-WAY EARTHQUAKE atACE <br /> I-WAY EARTHQUAKE BRACE <br /> A BUILDING SECTION a �3! SPRINKLER LEGEND <br /> 1 i'o 1 SPRINKLER <br /> ORIFICE SIZES EI '•' w ri <br /> FP 1 SCALE: 1/8"=1'-L" �r�e¢ d �= AND TYPE EI <br /> W �� <br /> 1 LVG 1 1 1 IG B IS I SPRAY O • I^ <br /> 1 E52 <br /> I ❑ <br /> YI <br /> Q ; C 1 3 I) A 3/I <br /> 3NI� )112J3d02Jd N 1 tz SPRAY a❑ 1^ <br /> 1 <br /> 1 Li a i e 1s z SIDEWAIL 4 <br /> INSTALL: <br /> .'.' INSTALL: <br /> 1-8" 45 BEND INSTALL: INSTALL: 1• 2 oar TYPE <br /> i1,-8"x6"TEE MJxMJ ® 1^ <br /> THRUST BLOCKING 1-S!-'a,xt6"TEE MJxMJxFL A 1-8"x6"TEE MJxMJxFL 2-8" GATE VALVES MJxMJ 60 LF 8" P 52 FLOW TEST <br /> T—rNtE HYDRANT ASSEMBLY A 1-FIRE HYDRANT ASSEMBLY SPRINKLER HEAD LEGEND <br /> THRUST BLOCKING THRUST BLOCKING 1-8' GATE VALVE BLOCKFLxMJING <br /> STALL: STATIC <br /> " <br /> FP-1 THRUST BLOCKING STATIC 61 PSI HEAD 11`A HERB fSC1TW <br /> -8" 45 BEND m uwuF. MODEL SIN nPE waxcx vzE FACTOR nxlsx nxnx Toe on <br /> H FH HRUST BLOCKING <br /> RESIDUAL 20 PSI <br /> 14 LF B" DIP CL 52�_ 84 LF 8"DIP CL 52 261 LF 8" DIP CL 52 <br /> 478 LF 8" DIP CL 52 <br /> F <br /> UG3 43 L " DIP CL 5N2 FLOW 2,052 GPM <br /> 3B LF B DIP CL 52� uc4 INS8A 2`BEND ELEV 517.81' <br /> IRIS A L: WALL DST RUS KING DATE 1 1 16/2022 <br /> 30 LF 8" DIP CL 52 FIRE SUPPLY LINE------ 1 INDIC OR LOCATION NODE 11546 <br /> 1-8" GATE VALVE MJEf�D <br /> THRUST BLOCKING DOUBLE DETECTOR CHECK VALVE ASSEMBL <br /> DATA BY EVERETT PUBLIC WORKS <br /> LOCATED INSIDE BUILDING <br /> VALVOTAL <br /> 90 LF 6" DIP LINE - CKI <br /> CKING �O� DUALIn CONTROL BY BATE <br /> 75 CL 52 �9 APPROVED FOR FABRICATION BY DATE <br /> G, GENERAL NOTES <br /> ALL NATfaAL AND IOURMLNT TO BE HEW AND UL USTED OR FM APPROVED. <br /> PROPOSED BUILDING N 2. PIPE ENIENSIOISTHUSLY ARE CENTER TO CENDR END.RISERS A DIMENSIONS <br /> 186,024 S F MJxMJ l SROWN KE GR(x-%)HALL ARE END ro END. <br /> 3. FARMQUAM MACIN.SHALL H PROVIDED IN ACCO�ANGf M1H <br /> P. 1- ANT A LY �,� xFP PAVPx1Er NO.a,zo1G Ean°x. <br /> FF=522.9T T KING 000000�o�� DESIGN CRITERIA: PIPFIRAPIK AND 13.2FON. �GRDNGEWRN <br /> NF A MORSIR NO.METHOD zOF HANGING EMNGX. <br /> ;11IS,2016 EDIIION <br /> 0000000000000000000000 MoouooUM ACTUAL STORAGE HEIGHTS VARY — 36" MUST BE """` o, BE IN �"°"""W�"FP"`"MPH ��IN GDRD'I <br /> r <br /> MAINTAINED BETWEEN TOP OF STORAGE AND SPRINKLER DEFLECTORS „",""" "EP"`o`FOIN"=ASE��"DED o000 0000 7.OWNER TO PROWDE ADEOUATE HEAT IN AREAS PROTECTED BY A WET PIPE GFRINKIER <br /> SYSTEM TO PREVENT WATER IN PIPES ROM FREEZING. <br /> 1. WAREHOUSE & MAIL ORDER: MAX STORAGE HEIGHT 12'-0" s.A�OTMIfGGGOr aECTRIU.GDNCES(IF REGUIRED)TO BE PROVIDED <br /> VVVV �V DESIGN STANDARD IS NFPA 13 USING RELIABLE'S JL-112 EXTENDED 9. PAINTING OF PIPE&EOUIPYENT(IF REQUIRED)TO BE PROVIpEO <br /> COVERAGE PENDENT SPRINKLER HEAD WITH A MINIMUM FLOW PRESSURE B OG. <br /> 10.FURRING Of PIPE k EQUIPMENT(IF REQUIRED)i0 BE PROVIDED <br /> OF 51 PSI WITH A MAXIMUM 15' HIGH ROOF FOR ORDINARY HAZARD BY OTHER` <br /> ` GROUP 2. THIS DESIGN ALLOWS FOR STORAGE OF THE FOLLOWING DESIGN CRITERIA <br /> 1 COMMODITIES: <br /> NSTALL: <br /> THRUSTS BBEND <br /> LOCKING !N1 TA L: PALLETIZED, BIN BOX, SHELF AND SOLID PILED STORAGE: <br /> 1a" 2zs EN INSTALL: PER TABLE 13.2.1 (NO OPEN TOP CONTAINERS) SEE NOTES THIS SHEET <br /> THRUST LOG <br /> G <br /> 1-8" INSTALL:x8" TAPPING TEE 22.5 BEND <br /> '''''' ''' THRUST BLOCK — ucs A. CLASS —IV ENCAPSULATED COMMODITIES <br /> ,',',',' INSTALL: 41 LF P CL 52 65 LF 8" DIP CL 52 ❑ 5ti 1-T TAPPING V E <br /> 45 BEND ° THRUST cKl MAXIMUM STORAGE HEIGHT = 12'-0" <br /> a'1-8"a"TE*VALVE MJxMJ F INSTALL:z B.CARTONLD NONEXPANDED PLASTICS <br /> ' 'T,NRLIST BLOCKING PIPE NOTES <br /> 1-8" 22.5 BEND F MAXIMUM STORAGE HEIGHT = 5'-0" <br /> ' THRUST BLOCKING <br /> 4z LF 6" DIP CL sz z7/F C. EXPOSED NONEXPANDED PLASTICS <br /> 58 LF CL 52 H a'°p 5 F 8" D CL 52 MAXIMUM STORAGE HEIGHT = 5'-0" <br /> ® -8"x6"TEE MJx MJxF <br /> 1-8"x6 xMJ 7 F 1-FIRE HYDRANT E LY <br /> 1-FIRE HY SSEMBLY. THRUST BLOCKI RACK STORAGE: PER TABLE 13.2.1 REVISIONS <br /> THRusT BLOC ING,','.','. INSTALL: H h`v INSTALL: SINGLE—ROW, DOUBLE—ROW, & MULTIPLE—ROW RACKING NO GATE BY BESCRIPTION <br /> 1E HYDRANT <br /> TEE ASSEMBLY v 1-8" 22.5 BEND FP (WITHOUT SOLID SHELVING) <br /> 1-FIRE HYDRANT ASSEMBLY -I Q THRUST BLOCKING �PZ <br /> THRUST BLOCKING S<F o (NO OPEN TOP CONTAINERS) <br /> • 56 LF 8" DIP CL 52 g, � �� <br /> °'pc �g 18 LF 8" D 2 <br /> INSTALL: A. CLASS I—IV ENCAPSULATED OR NONENCAPSULATED COMMODITIES <br /> 1-8%6"TEE MJxMJxFL sz� MAXIMUM STORAGE HEIGHT = 10'-0" <br /> -B GATE VALVE BFLxMJ <br /> LOCKING <br /> B.CARTONED NONEXPANDED PLASTICS <br /> THRUST BLOCKING O — <br /> ucz MAXIMUM STORAGE HEIGHT — 5'-0" J <br /> INSTALL: 45 LF 8" DIP CL 52 C. EXPOSED NONEXPANDED PLASTICS < <br /> 1-8° TEE MJxMJxFL MAXIMUM STORAGE HEIGHT 5'-0" FOUSHEE & ASSOCIATES COMPANY, INC. <br /> ' 1-12" GATE VALVE <br /> BELL - , WA AVE 11 SE <br /> 1-12x8" REDUCER MJxFL UGl � BELLEVUE, WA 98005 <br /> 2-8" GATE VALVES FLxMJ INSTALL: 2. OFFICES, BATHROOMS & BREAK ROOMS: MATTHEW CHILES: 425-746-1000 <br /> THRUST BLOCKING INSTALL: 1-16"x8"TAPPING TEE <br /> 2-8" 22.5 BEND / 1-8"TAP PROJECT MINE: <br /> VALVE LIGHT HAZARD C <br /> THRUST BLOCKING THRUST BLOCKING G <br /> SRC m MCKESSON TI <br /> 55 LF 8" DIP C 52 <br /> 7007 SEAWAY BLVD <br /> EVERETT, WA 98203 <br /> ' �/P PATRIFP099CF <br /> , ' +PATRIOT WWW.PATRIOrFIRE.COM <br /> pielrod®pOlriotf ire.com <br /> SITE PLAN FIRE PROTECTION,INC. <br /> TACO A, AVENUE EAST TEL: (253) 922-6150 <br /> _ SCALE:1"=50'-O" TACO MA, EK 98424 FAX:(253) 922-6150 <br /> DESIGNER EREK STRICKLAN SHEET <br /> DATE 7/29/24 F P 1 <br /> JOB NO. 11-2410 OF 5 <br />