Permit #: RB1502-006 <br />Site Address: <br />U <br />a <br />"THE C.Q.E. HAS NOT BEVIE�IED THESE <br />PLANOS FOR COMPLIAAXE WITH (,CVO 0111Y.55" <br />SPRINKLER VALVES AND COMPONENTS <br />MUST BE MAINTAINED AT 40OF <br />MINIMUM TEMPERATURE PER NFPA 13 <br />A Benchlrlark Is Required On Sits <br />To 'Verify Appro'vr.1-d .Building ,f rj <br />C PE �,-ijojCASED ELECT RODE <br />(UFER ROUND) REQUIRED <br />PER NEC 2 0.50 <br />(INSPECTED AT FOOTINGS) <br />PROPANE TANKS, HEAT PUMPS AND <br />OTHER EQUIPMENT OR APPURTENANCES <br />MAY NOT BE LOCATED IN THE FRONT <br />Additional Permits Are Required <br />AND SIDE SETBACKS. PROPANE TANKS <br />For This Project To Include: <br />REQUIRE ADDITIONAL PERMITS ISSUED <br />BY THE EVERETT FIRE DEPARTMENT <br />Plumbing ❑ Sprinkler <br />PRIOR TO INSTALLATION. <br />E:1 Mechanical ❑ Fire Alarm <br />El Electrical <br />It is owners responsibility to eatablisb xW gWW AU <br />property lines, <br />ort AD-st Plygon 0 h w�� <br />toompnn,&Aw <br />PROJECT TEAM <br />Owner/Developer Polygon Northwest Company <br />11624 SE 5th Street, Suite 200 <br />:Bellevue, WA 98005 <br />(425) 586-7700 <br />Architect: Milbrandt Architects, Inc., P.S. <br />25 Central Way, Suite 210 <br />Kirkland, WA 98033 <br />(425) 454-71.30 <br />Structural Engineer: CT Engineering <br />180 Nickerson Street - Suite 302 <br />Seattle, Wa. 98109 <br />(206) 285-0618 <br />Civil Engineer Core Design, Inc. <br />14711 NE 29th Place, Suite 101 <br />Bellevue, WA 98007 <br />(425) 885-7877 <br />GENERAL NOTES <br />1. Comply with 2015 IRC and all applicable codes and ordinances of the local. <br />jurisdiction and the State of Washington. <br />2. Do not scale drawings. <br />3. Verify all rough -in dimensions for equipment provided in this contract or <br />by others. All rough -ins shall be approved and fireblocking shall be <br />installed prior to framing inspection. <br />4, Verify size and location of and provide all openings through floors and <br />walls, furring, anchors, inserts, rough bucks and backing for surface <br />mounted items. <br />5. Provide furring as required to conceal mechanical and electrical work in all <br />finished areas. <br />6. All swinging doors not located by dimensions on plans, interior elevations, <br />or details shall be 3" from face of stud to edge of rough openings or <br />centered between room partitions as shown. <br />7. Plans are .drawn assuming the following rough openings: <br />Swinging doors: Nominal size +2". <br />Bi-Fold doors: Nominal size +1-1/2" <br />Bi-Pass doors: Nominal size +0". <br />Windows: Nominal size +0". <br />Sliding glass doors: Nominal size +0". <br />8. Fill where required with earth free from organic material. Compact fill in <br />12" layers maximum. <br />9. "Finish Floor" refers to the top of concrete slab or top of wood floor <br />sheathing . <br />10. Exterior walls shall be 2x6 studs at 16" o.c. and interior walls shall be 2x4 <br />studs at 16" o.c., unless noted otherwise. <br />11. Unless otherwise noted, plan dimensions are to face of studs and face of <br />concrete walls. <br />12. Refer to interior elevations for cabinet and counter lengths, dimensions, <br />countertop materials and detail reference. Verify all existing dimensions <br />before installation. <br />13. Provide caulking between sole plates and subfloor and between rim joists at <br />both top plate and subfloor. <br />14. Hydrants shall be in service prior to start of framing. <br />15. Provisions shall be made for the control and drainage of surface water <br />around building. IRC Sec R441.3. <br />16. Milbrandt Architects is not responsible for construction means, methods, <br />techniques or procedures, or for the safety precautions and programs in <br />connection with the work, and is not responsible for the failure of any <br />contractor or subcontractor to carry out the work in accordance with the <br />various contract documents and or governing jurisdiction regardless of <br />x IF BUILDING IS NOT POSITIONED ASS what is shown on these drawings. <br />INDICATED ON APPROVED SITE PLAN. <br />A NEW SITE PLAN SHALL BE SUBMIT- <br />TED. NO FURTHER INSPECTIONS L ILL <br />Roof trusses to be designed <br />THE <br />BE MADE ON THIS PROJECT UNTI and drawing prepared by <br />REVISED SITE PLAN HAS BEEN APPROV- a State licensed structural <br />ED BY THE BUILDINGIPUBLIC WORKS engineer. <br />DEPTS. <br />GENERAL <br />INFORMATION <br />` GRADING AND DRAINAGE <br />Provisians shaft be made for the control and drainage of surface Building Code: <br />2015 International Residential Code <br />with State Amendments as <br />water around buildings by: gutters, drain lines, ir.l-ts ai' d catch <br />modified and adopted by the local jurisdiction. <br />basins or other necessary drainage structures and shall be installed Floor Areas: <br />1st Floor Garage <br />433 SF <br />where storm water disposal cannot be obtained without their use or <br />Covered Porch <br />120 SF <br />where erosion cannot be prevented by finish grading and planting. <br />1st Floor Residence <br />1,070 SF <br />Dry wells shall not be installed in areas where the soil is not well <br />2nd Floor Residence <br />I,472 SF <br />Total Enclosed Building Area <br />2,542 SF <br />drained andJor porous. <br />Construction Type: <br />V-B <br />2„ Grad-ing shall be provided to insure: <br />(a) Diversion of water away from buildings. <br />(b) Prevention of standing water and soil saturation detrimental <br />to structures and lot use. <br />(c) That natural drainage channels or basins are not blocked or <br />filled. <br />(d) Provisions for the disposal of water from a lot. <br />te) Protection of adjoining property, <br />ENERGY NOTES <br />1. Code: 2015 Washington State Energy Code. <br />2. Compliance: Chapter 4 using climate zone catagory 5 & marine 4 for all. calculations. <br />All residential units shall comply with the Requirements By Component Table 402.1.1. <br />Including but not limited to the following: <br />Code Requirements <br />Window U-Factor 0.30 - ( 0.28 used) <br />Ceiling R-Value R-49 <br />Wood Frame Wall R-Value R-21 int. <br />Floor R-Value R-30 - (R-38 used) <br />Below Grade Wall 10/15/21 int. + TB <br />Slab R-Value & Depth R-10, 2ft <br />"int." (intermediate framing) denotes standard framing 16" o.c. with headers <br />insulated with a min. of R-10 (see 12/132) and corners fully insulated (see 12/1) 1). <br />Note to Bldg. Dept. An Energy Credit Checklist was submitted with Application. <br />3. Efficient building envelope with R-38 floors and vertical fenestration of U=.28. to <br />comply with Table 406.2, Option 1a. <br />4. A high efficiency gas furnace with a AFUE of 94% will be used to comply with Table <br />406.2, Option 3a. <br />5. Efficient water heating with showerheads and kitchen faucets rated < 1.75 gpm and <br />lavatory faucets rated :5 1.00 gpm to comply with Table 406.2, Option 5a. <br />6. Efficient gas water heating with a minimum EF of 0.91 to comply with Table 406.2, Option <br />5c. <br />6. See D 1 for Energy Notes. <br />7. Fuel for heat and domestic hot water is Natural Gas. <br />8. Hot water piping shall be insulated to a minimum of R-4 in both heated and unheated <br />spaces per R403.4.2. <br />9. For insulation values see the Insulation Box on Sheet A2. <br />10. No air conditioning will be provided; <br />VENTILATION NOTES <br />1. Design Criteria: 2015 International Residential Code and the 2015 International <br />Mechanical Code with Washington State amendments. <br />2. System Type: <br />Per IRC Section M1507-Local exhaust ventilation <br />Per IRC Section M1507.3.5-Intermittently operated whole house ventilation systems <br />integrated with forced air ventilation systems. <br />3. Approach: Prescriptive- per IRC Section M1507 <br />4. Specifics: See Electrical Plans <br />5. Outdoor air connection to the return air stream shall be located upstream of the forced -air <br />system blower and shall not be connected directly into a furnace cabinet. <br />6. The system will be equipped with a motorized damper connected to the automatic <br />ventilation control as specified per IRC Section M1507.3.2. <br />7. Specific requirements for the mechanical system, such as but not limited to the duct size are <br />to be determined by the mechanical bidder/design contractor. <br />DESIGN LOADS <br />See sheet S 1.0 for Design Loads. <br />LIST OF DRAWINGS <br />Al Cover Sheet <br />A2 First and Second Floor Plans & Stair Plan <br />A3 First and Second Floor Electrical Plans <br />A4 Foundation Plan <br />A5 Floor Framing & Shearwall Plans <br />A6 Roof Plan & Roof Framing Plan <br />A7 Exterior Elevations, Sections, and Interior Elevations <br />A8 Details <br />S1.0 <br />Structural Notes <br />S1.1 <br />Shearwall Schedule & Details <br />S1.2 <br />Holdown Schedule & Details <br />S6.0 <br />Typical Concrete Details <br />S6.1 <br />Miscellaneous Details <br />S9_0 <br />Typical Floor Framing Details <br />S9.1 <br />Typical Roof Framing Details <br />D1 = <br />Details.:.. __ <br />D2 <br />Details <br />D3 <br />Details <br />*NOTE: 2015 IRC <br />) LYGO N W LH LLC <br />anNamel <br />10/2015 <br />R <br />R BASIC/2015 IRC - PLAN #3580 ABC <br />;5 r Date: <br />_Jcb Site Set Fire/Planning Set <br />5052 REGISTERED <br />ARCHITECT <br />ROBERT E. WEIBLE <br />STATE OF WASHINGTON <br />-6 <br />tA <br />L <br />H <br />a <br />4 <br />Q- <br />'� <br />z <br />�G <br />N <br />V <br />a <br />o <br />0 <br />WNW <br />L`.. a <br />H <br />Z <br />rn O <br />� <br />CL <br />1 <br />0 <br />> <br />� <br />V <br />00 <br />L0 <br />rML <br />Z <br />M <br />> <br />W <br />O <br />Job No.: 14-38 <br />Sheet No.: <br />