Laserfiche WebLink
#: <br /> Everett Fire Dept Permit FA2310-021 <br /> .Notes: A a w m <br /> i(NFPA 72) I Site Address: 2701 Wetmore Ave W <br /> EVERETT Applicant: Home Run Electric LLC s yWl 0) <br /> -See Attached Fire Alarm System r I Application Date: 10/26/2023 Lim"y H N 3 <br /> Acceptance Test Checklist. Description: Fire Alarm System N Q o <br /> m� <br /> •24 hour Battery Test-At the time of the I = W LCinspection/test provide proof verifying that the Review Status: 1st Review by City&Peer Reviewers Review Date: 11/02/2023 <I— <br /> panel has been operating on secondary power I c o <br /> (battery)for 24 hours.No other problems a H m <br /> shall be indicated on the panel. I 0 ro F <br /> IL701 W T M 0 R E N r <br /> 'I Ev E i Y Q <br /> I-Record of Completion-For all new EVERETT <br /> systems,a Record of Completion is required Everett Fire Dept.Permit Review o 0 0 to be entered into The Compliance Engine I Status:Approved 0 Z„ <br /> poor to permit final. Reviewed By:BPearson N a a <br /> F I R E ALARM SYSTEM I�(wwW'.thecomplianceengine. 11/02/2 3 39 54 <br /> —__________— P______J PM INSTALLING CONTRACTOR: <br /> PROJECT INFORMATION DEVICE LEGEND II t <br /> SYMBOL MANUFACTURER PARTNO DESCRIPTION OTY I <br /> O SILENT KNIGHT SK-520B FIRE ALARM CONTROL PANEL,CONVENTIONAL,10-30 ZONE 1 �O I yl E,`U N <br /> NAME: 2701 WETMORE "s - ""' E L E C T R I C <br /> ADDRESS: 2701 WETMORE NAc SILENT KNIGHT 5496 54966A INTELLIGENT REMOTE POWER SUPPLY 1 _.,nev ="""�® zn3s4a�AwwL3�..00a vu seou <br /> EVERETT,WA 98201 °^^• .„. r(4zq sar-aryl J II—) s <br /> ❑ <br /> /,i RONvryY,w�nneNCN°bsom F SILENT KNIGHT SK-PULLSA ADDRESSABLE MANUAL PULL STATION,SINGLE-ACTION 1 <br /> SCOPE OF WORK JB GENERIC GENERIC WIREPATH JBOX 01 HARDWARE,JUNCTION BOX 3 - :.,°,Q ^ � , - 21118 66 TH AVE- W <br /> LYone:(425)489-0791 <br /> NNWOOD,WA 98036 <br /> RECONFIGURING EXISTING SK-5808 ADRESSABLE FIRE ALARM CONTROL PANEL INTO NEW 0 SILENT KNIGHT SK-MONITOR-2 ADDRESSABLE DUAL MONITOR MODULE 6 �� —� „ —0- 2x® �. Ph <br /> D g § Fax: (425)489-7996 <br /> RESIDENTIAL OCCUPANCIES AND REVISED BUILDING CONFIGURATION. h <br /> Q SILENT KNIGHT SK-RELAY ADDRESSABLE RELAY MODULE 3 sew°e.«vQ m�a�� eel ouo9 <br /> IM SILENT KNIGHT SK-ISO FAULT ISOLATOR MODULE 4 pnIX& „•,.ma etl •• \,u.,.aaaaO" <br /> FIRE ALARM CONTRACTOR �F] SYSTEM SENSOR HW-LF SOUNDER,LOW FREQUENCY,WALL,WHITE 78 mn".w A°c"-0©oPotl"°M use=maeErsv ee Q�Po <br /> 0 <br /> NAME: HOME RUN ELECTRIC ® SILENT KNIGHT SK-PHOTO ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR 24 q °" "°'9 <br /> ADDRESS: 21118 66TH AVE W <br /> LYNNWOOD,WA 98038 ® SILENT KNIGHT 3K-PHOTO-T ADDRESSABLE PHOTOELECTRIC 3MOKEIHEATDETECTOR 7 � ���"_�- �,',�® °°°"`"' _ l <br /> PHONE: (425)489-7996 SYSTEM SENSOR P2RK 2-WIRE HORN STROBE,STANDARD CD,OUTDOOR 7 , <br /> FAX (125)489-7996 �P .-• ° 0 <br /> SYSTEM SENSOR P21RL 2-WIRE,HORN STROBE,RED 1 S <br /> APPLICABLE CODES AND STANDARDS SYSTEM SENSOR P2WL 2-WIRE,HORN STROBE,WHITE 28 fi a r C <br /> NFPA 72 NATIONAL FIRE ALARM CODE 2019 EDITION SYSTEM SENSOR PC2WL 2-WIRE,HORN STROBE,WHITE 1 <br /> INTERNATIONAL BUILDING CODE 2015 EDITION C <br /> INTERNATIONAL FIRE CODE 2015 EDITION SYSTEM SENSOR SWL STROBE,WHITE B <br /> NFPA 70 NATIONAL ELECTRICAL CODE 2020 EDITION a V <br /> CABLE AND WIRE LEGEND <br /> LABEL LINETYPE AWG RESISTANCE DESCRIPTION N <br /> CIRCUIT LABELING LEGEND A 16 7.77 2 COND.SOLID COPPER FPLR <br /> DEVICE IDENTIFIER <br /> B ---------------- 14 3.07 2 COND.SOLID COPPER FPLR ANALOG UNSHIELDED VICINITY MAP <br /> SLC1• m <br /> SLC=SIGNALING LINE CIRCUIT C ----------------------- 18 6.7000 4COND.SOLID COPPER FPLR ANALOG UNSHIELDED <br /> NAC=NOTIFICATION APPLIANCE CIRCUIT <br /> CIRCUIT IDENTIFIER ADRIAN M.STEIK <br /> it Engir f Tu w.Levrl4 <br /> NICET[ehirulien lAmbw:0937(16 <br /> NuxFoeixiy SigmNre �lw=r�3'U <br /> ABBREVIATIONS <br /> INPUTS <br /> A AMPERE J-BOX JUNCTION BOX GENERAL SYSTEM OPERATION <br /> AFF ABOVE FINISHED FLOOR kV KILOVOLT I^L <br /> AHU AIR HANDLING UNIT WA KILOVOLTAMPERE ACTIVATION OF ANY SMOKE DETECTOR,HEAT DETECTOR OR MANUAL PULL STATION SHALL: v� <br /> Uj <br /> AL ALUMINIUM kW KILOWATT - VISUALLY INDICATE THE APPROPRIATE ZONE ON THE FACP: O SHEET INDEX <br /> AMP AMPERE kWh KILOWATT HOUR -- WHAT TYPE OF DEVICE WAS ACTIVATED. <br /> AWG AMERICAN WIRE GAUGE MFR MANUFACTURER -- FROM WHICH AREATHEALARM WASGENERATED. U K W <br /> BLDG BUILDING MECH MECHANICAL - ACTUATEEXTERIORSTROBE. J O W <br /> C CONDUIT MIN MINIMUM - TRANSMIT THE APPROPRIATE ZONE ALARM SIGNAL TO THE APPROVED CENTRAL m m U SHEET NO. SHEET DESCRIPTION O 0 <br /> CB CIRCUIT BREAKER (A) NEW STATION FOR COMMUNICATION TO THE FIRE DEPARTMENT. z0 } =O = o y w A/ <br /> CCTV CLOSED CIRCUIT TELEVISION NAC NOTIFICATION APPLIANCE CIRCUIT F w w .�U. Y FAD. TITLE SHEET L Al <br /> CKT CIRCUIT NEC NATIONAL ELECTRIC CODE THESYSTEMSHALLBEELECTRICALLYSUPERVISEDSOTHATTHEOCCURRENCEOFA z ¢ c = 3 N w N W <br /> CLG CEILING NEUT NEUTRAL SINGLE OPEN,OR GROUND FAULT ON ANY FIELD WIRING,OR FAILURE OF PRIMARY POWER O2 > > Q U 0 <br /> r m oq = t ^ m p FA1.1 LEVEL 1 FLOOR PLAN-FIRE ALARM SYSTEM <br /> CO CONDUIT ONLY NFPA NATIONAL FIRE PROTECTION ASSOCIATION SUPPLY,WILL CAUSE A VISUAL'TROUBLE'AT THE FACP B REMOTE ANNUNCIATOR AND Q 4 w U 3 } m <br /> COMM COMMUNICATION NC NORMALLY CLOSED 'TROUBLE"SIGNAL SHALL BE TRANSMITTED TO THE APPROVED CENTRAL STATION FOR > ¢ LL 3 z w m O f <br /> z FA1.2 LEVEL 2 FLOOR PLAN-FIRE ALARM SYSTEM <br /> CU COPPER NIC NOT IN CONTRACT APPROPRIATE ACTION. 6 0 w l7 2� w f O v, <br /> DCV DOUBLE CHECK VALVE NO NUMBER;NORMALLY OPEN Q F 3 U, O <br /> CIA DIAMETER NTS NOT TO SCALE a a g 0 J w FA1.3 LEVEL 3 FLOOR PLAN-FIRE ALARM SYSTEM <br /> Dlsc DISCONNECT oD OVERHEAD DOOR;OVERALL DIAMETER G a N N -- _- 2 ¢ w j z FA2.1 RISER DIAGRAM-FIRE ALARM SYSTEM <br /> ON DOWN PV POST INDICATOR VALVE w = ¢ ] w a > O = / <br /> DO DOOR OPERATOR PINE PANEL Lri <br /> o a ¢ w w O u- <br /> (E) ¢ FA2.2 BATTERY AND CIRCUIT CALCULATIONS-FIRE ALARM SYSTEM <br /> EA EXISTING PVC POLYVINYL CHLORIDE(PLASTIC) w ¢ < < < z U 3 X x IL. w f <br /> EA EACH PWR POWER 0 = ¢ Q ¢ = z z z H C7 <br /> EF EXHAUST FAN QN QUANTITY O z w Ce w O w z ¢�¢ <br /> ELEC ELECTRIC READ REQUIRED u, 2 LL z W C07 O � vai mw iz CD w 1 <br /> ELEV ELEVATOR RH RANGE HOOD L <br /> EMT ELECTRICAL METALLIC TUBING RMC RIGID METALLIC CONDUIT ACTUATE ALARM SIGNAL AT FACP 0 0 9 0 00 0 0 0 0 9 0 0 GENERAL NOTES L III <br /> EOL END OF LINE RESISTOR SF SUPPLY FAN;SQUARE FEET ACTUATE ALARM SIGNAL AT ANNUNCIATOR 0 0 0 0 0 0 0 0 I— W <br /> EOLR END OF LINE RESISTOR SLC SIGNALING LINE CIRCUIT <br /> EXIST EXISTING SPEC SPECIFICATION TRANSMIT ALARM SIGNAL TO CENTRAL STATION <br /> F FIXED ST SHUNT TRIP LU <br /> FA FIRE ALARM STD STANDARD ACTIVATE ALL BUILDING NOTIFICATION APPLIANCES <br /> FAA FIRE ALARM ANNUNCIATOR TEL TELEPHONE ACTUATE SUPERVISORY SIGNAL AT FACP • ALL FIRE ALARM SYSTEM WORK COMPLETED UNDER THE SCOPE OF THIS FIRE ALARM PLAN REVIEW SHALL BE FIELD <br /> FACP FIRE ALARM CONTROL PANEL TELCOTELEPHONE COMPANY VERIFIED BY FIRE INSPECTION PERSONNEL AND THE FIRE CODE OFFICIAL. <br /> FAPS FIRE ALARM POWER SUPPLY TEMP TEMPORARY TRANSMIT SUPERVISORY SIGNAL TO CENTRAL STATION <br /> • VISIBLE NOTIFICATION APPLIANCES SHALL REMAIN ACTIVE(FLASHING)WHEN THE AUTOMATIC AND MANUAL FIRE ALARM O ` <br /> LU <br /> FARA FIRE ALARM REMOTE ANNUNCIATOR TS TAMPER SWITCH ACTUATE TROUBLE SIGNAL AT FACP <br /> FBO FURNISHED BY OTHERS TYP TYPICAL a SYSTEM ISSILENCED. <br /> FDC FIRE DEPARTMENT CONNECTION UGND UNDERGROUND TRANSMIT TROUBLE SIGNAL TO CENTRAL STATION • • • • FIRE ALARM SYSTEM SHALL TRANSMIT TROUBLE,SUPERVISORY AND FIRE SIGNALS DIRECTLY TO THE COMMUNICATIONS <br /> FEC FIRE EXTINGUISHER CABINET ILL UNDERWRITERS 0 ELEVATOR CONTROL: CENTER REMOTE SUPERVISING STATION <br /> FH FIRE HYDRANT UON UNLESS <br /> STATION. <br /> OTHERWISE NOTED (y <br /> FPL FIRE POWER LIMITED V VOLT PRIMARY ELEVATOR RECALL MOUNT PULL STATIONS AT 42 AT ACTIVATOR WITHIN 5 OF LATCH SIDE OF EXIT DOORS <br /> J <br /> FPLR FIRE POWER LIMITED RISER VA VOLT AMPERE ELEVATOR CONTROL: • MOUNT AUDIO VISUAL DEVICES AT 80"ABOVE FLOOR LEVEL <br /> FP LP FIRE POWER LIMITED PLENUM VAC VOLTAGE,ALTERNATING CURRENT I— <br /> • A DEDICATED 120VAC,20A BRANCH CIRCUIT BREAKER SHALL BE PROVIDED,MARKED IN RED,LOCK-ON PROVISION AND w <br /> FS WATER FLOW SWITCH VDC VOLTAGE,DIRECT CURRENT ALTERNATE ELEVATOR RECALL w <br /> FSD FIRE/SMOKE DAMPER VR VANDAL RESISTANT IDENTIFIED AS"FIRE ALARM CIRCUIT CONTROL".THE LOCATION OF THE CIRCUIT BREAKER WILL BE PERMANENTLY N <br /> G GROUND W WATT ELEVATOR CONTROL: IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. <br /> GEC GROUNDING ELECTRODE CONDUCTOR W/ WITH FIRE HAT <br /> GEN GENERATOR W/O WITHOUT DRAWN BY RMV <br /> HT HEATTRACE WP WEATHERPROOF <br /> IDC INITIATING DEVICE CIRCUIT Z IMPEDANCE SEQUENCE OF OPERATIONS MATRIX CHECKED BY: Adrian M.Steik <br /> PLOTOATE: 10/4/22 <br /> PROJECT NUMBER: 2 2-012 <br /> FAO , 1 <br /> DRAWING ONLY TO SCALE IF PLOTTED AT 24"X 36" SHEET N..BEa: <br />