My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7209 6TH AVE W 2024 Plans 2025-11-06
>
Address Records
>
6TH AVE W
>
7209
>
Plans
>
7209 6TH AVE W 2024 Plans 2025-11-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2025 10:55:24 AM
Creation date
11/6/2025 10:55:06 AM
Metadata
Fields
Template:
Address Document
Street Name
6TH AVE W
Street Number
7209
Permit
B2401-012
Year
2024
Notes
GARAGE CONVERSION TO CREATE AN AFH
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
JOEY <br /> D N <br /> GENERAL STRUCTURAL NOTES <br /> CODE <br /> DESIGN IS IN ACCORDANCE WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE(I.R.C.) 0 <br /> N <br /> ADULT FAMILY HOME 00 <br /> A DWELLING,LICENSED BY THE STATE OF WASHINGTON DEPARTMENT OF SOCIAL AND HEALTH SERVICES, (3) <br /> IN WHICH A PERSON OR PERSONS PROVIDE PERSONAL CARE,SPECIAL CARE,ROOM AND BOARD TO MORE Q <br /> THAN ONE BUT NOT MORE THAN SIX ADULTS WHO ARE NOT RELATED BY BLOOD OR MARRIAGE TO THE <br /> PERSON OR PERSONS PROVIDING THE SERVICES.AN EXISTING ADULT FAMILY HOME MAY PROVIDE <br /> SERVICES TO UP TO EIGHT ADULTS UPON APPROVAL FROM THE DEPARTMENT OF SOCIAL AND HEALTH 1 ' <br /> SERVICES IN ACCORDANCE WITH RCW 70.128.066. rr <br /> FOUNDATIONS W <br /> EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL,ASSUMED BEARING CAPACITY OF 1500 PSF.ALL <br /> EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF V-6"BELOW ADJACENT EXTERIOR FINISHED GRADE, W <br /> CAST-IN-PLACE CONCRETE W <br /> Pp=3,000 PSI @ 28 DAYS.MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A <br /> MAXIMUM OF 6-3/4 GALLONS OF WATER PER 94#SACK OF CEMENT.NO SPECIAL INSPECTION REQUIRED. : <br /> TOTAL AIR ENTRAINMENT SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT.MAXIMUM W <br /> SIZED AGGREGATES IS 1-1/2 INCHES.MAXIMUM SLUMP IS 4INCHES.ALL REINFORCING STEEL DOWELS, > <br /> ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONCRETE. Q ANCHOR BOLTS FOR PRESSURE TREATED SILL PLATES TO FOUNDATION WALLS TO BE s%"DIAMETER WITH <br /> 7 INCH MINIMUM EMBEDMENT INTO CONCRETE AND MAXIMUM SPACING OF 2 FEET ON CENTER UNLESS Z <br /> NOTED OTHERWISE ON THE PLANS.MINIMUM 2 BOLTS PER SILL PLATE PIECE.ONE BOLT TO BE PLACED Q F- <br /> WITHIN 6INCHES OF EACH END OF THE SILL PLATE. F-- (O <br /> CARPENTRY Q <br /> ALL GRADES SHALL CONFORM TO W WPA GRADING RULES FOR WESTERN LUMBER,LATEST EDITION. Q N <br /> PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINST WOOD.ALL WOOD IN CONTACT J <br /> WITH CONCRETE SHALL BE PRESSURE TREATED PER PRESERVATIVE TREATMENT NOTE.FASTENERS <br /> ® INSTALLED IN PRESERVATIVE TREATED WOOD SHALL BE HOT-DIPPED GALVANIZED PER I.R.C.SECTION <br /> R319.3.NAILING SHALL CONFORM WITH I.R.C.TABLE R602.3(1)&R802.10 OR I.B.C.TABLE 2304.9.1.ALL <br /> STRUCTURAL LUMBER SHALL BE AS NOTED BELOW: <br /> 2. <br /> STUDS HEM-FIR#2--------Fb=850 PSI <br /> C 2x FLOOR&ROOF JOIST HEM-FIR#2---—------—Fb=850 PSI <br /> 4x BEAMS DOUG-FIR/LARCH#2---------Fb=875 PSI <br /> 6x BEAMS Do <br /> #2------Fb=850 PSI <br /> COLUMNS Do G-FIR/LARCH#2----Fb=675 PSI <br /> LUMBER NOT NOTED DOUG-FIR/LARCH#2--------Fb=850 PSI <br /> .,.... .. .. ::' .: <br /> MISCELLANEOUS HANGERS 70 BE PROVIDED BY SIMPSON COMPANY.ALL HANGERS SHALL BE FASTENED <br /> 70 WOOD WITH PROPER NAILS,ALL HOLES SHALL BE NAILED.MACHINE BOLTS TO BE A-307.ANCHOR <br /> .. .. <br /> BOLTS INTO CONCRETE SHALL BE%"DIAMETER WITH 7 INCHES OF EMBEDMEND INTO CONCRETE UNLESS <br /> ..: .. <br /> NOTED OTHERWISE ON THE PLANS.ALL NAILS SHALL BE COMMON WIRE NAILS.NAILING SHALL BE IN <br /> .. ACCORDANCE WITH I.B.C.SCHEDULE.16d COMMON NAIL DIAMETER-(0.1621NCH).LAMINATED STUDS <br /> SHALL BE NAILED WITH(2)ROWS 16d COMMON NAILS(dJ 6"O.C. W <br /> FLOOR SHEATHING 2 <br /> SHEATHING SHALL BE%INCH TONGUE&GROOVE,A.P.A.RATED SHEATHING.SPAN RATING°%a WITH O <br /> LONG DIMENSION PERPENDICULAR TO SUPPORTS.UNLESS NOTED OTHERWISE NAIL WITH 10d COMMON <br /> NAILS AT 6 INCHES ON CENTER A7 SUPPORTED PANEL EDGES&10 INCHES ON CENTER AT INTERMEDIATE } <br /> SUPPORTS.THE FLOOR SHEATHING SHALL BE GLUED TO THE JOIST AND THE TONGUE AND GROOVE <br /> JOINTS WITH AN APPROVED ADHESIVE. _J <br /> ROOF§HEATHING 2 <br /> ✓�."/O I I I '� I SHEATHING SHALL BE%s"A.P.A.RATED SHEATHING.SPAN RATINGS INSTALLED WITH LONG DIMENSION ILL <br /> ACROSS SUPPORTS.PANEL END JOINTS SHALL OCCUR AT SUPPORTS. <br /> .NAIL PANEL EDGES WITH Bd NAILS <br /> AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. J <br /> FROFOSED GARA( E GONVERSION INTO S WALL SHEATHING <br /> BEDROOMS AND INTERIOR ALTERATION SHEATHING TO BE%s"A.P.A.RATED SHEATHING.SPAN RATING°%.PANEL END JOINTS SHALL OCCUR AT <br /> SUPPORTS.NAIL PANEL EDGES WITH 8d NAILS AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT Q <br /> INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON THE DRAWINGS. Z <br /> REINFORCEMENT 0(� <br /> fy=40:10118I FOR#5&SMALLER Z <br /> E}YERJJU/SAIALEMMAIRD AND MIRAF MAIRD N=60,000PSIFOR#68LARGER v <br /> 120—I 6 TH AVE ms�}}aaW NOTE:ALL BOLTS,WASHERS,NAILS,SCREWS,HANGERS AND FRAMING STRAPS THAT COME INTO �W <br /> EVERETT, WA —IV203 CONTACT WITH ACQ TREATED LUMBER SHALL BE STAINLESS STEEL OR HOT-DIPPED GALVANIZED STEEL. 0 <br /> Of <br /> INDEX OF DRAWINGS 0_0 <br /> S 17E ADDRESS <br /> SHEET# DESCRIPTION <br /> 720`1 &TH AVE W Al COVERSHEET <br /> EVERETT, WA L18203 R-slope: <br /> A2 2018 ALTERATION WSEC,2018 WSEC,AFH NOTES Q—REIs.N DDE TD <br /> I A3 FASTENING SCHEDULE&BUILDING SECTION MAY 0 9 2024 <br /> aDl,al DATED <br /> F A RC E L ID A4 DETAIL SHEET CITY OE EVERET7 <br /> m l Services <br /> 00708000004400 A5 EXISTING FLOOR PLAN <br /> A6 PROPOSED MAIN FLOOR PLAN <br /> A7 PROPOSED FLOOR FRAMING PLAN,ROOF PLAN, <br /> EXISTING FRONT ELEVATION AND PROPOSED FRONT ELEVATION <br /> Q <br /> � Wg <br /> THESE DOCUMENTS HAVE NOT BEEN '� Q Q <br /> APPROVED FOR THE ISSUANCE OF ;T U <br /> PUBLIC WORK,MECHANICAL,FIRE .•.._...,;;as <br /> SUPPRESSION,ELECTRICAL OR W <br /> PLUMBING PERMITS Permit#: B2401-012 z W <br /> Site Address: 72096TH AVEW }Z <br /> Owner. EYE„RJ13�j}EjviM DAND MBAFMAIRD O W Q <br /> CITY OF EVERETT Tenant: ��soi' <br /> REVIEWED FOR PERMIT App.Date: 1/7/2024 <br /> Permit Type: ADULT FAMILY HOME BUILDING <br /> Subtype: CONVERT EXISTING RESIDENCE TO ADU LT <br /> FAMILY HOME <br /> All electrical,mechanical,plumbing Description: GARAGE VERSION TO CREATE AN AFH <br /> and framing installed/altered without Z � <br /> Permit,inspection,and a Reviewed By: ate: <br /> be uncovered for inspection.oval must �iPet _1ob Site Set <br /> 230041 <br />
The URL can be used to link to this page
Your browser does not support the video tag.