Laserfiche WebLink
2 _. 3 4 5 <br /> Emerson ES Portable 11 DYKEMAN <br /> D <br /> APPROVED <br /> Office of Community,Planning&Economic Development <br /> Q�P)LA�N NI/N,GDEPARTMENT <br /> Name- , � _DATE:I't_2-* II�,,/a((�==rl� M <br /> REVEO V CDVICINITY MAP PROJECT INFORMATION GENERALNOTES ARCHITECTURAL SYMBOLS APR 25 2M D <br /> CITY OF EVERETT <br /> 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE THE WORK Permit Services <br /> LEGAL DESCRIPTION OF ALL TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT. <br /> SEC 18 TWP 28 RGE 02 BEG NW CDR SEC THE 1316.11FT TH S 759.62FT TPB TH 2. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ALL DETAIL NUMBER <br /> W 716.14FT TH S TO S UN NW1/4 NW1/4 TH E ALG S W SO SUB 716.14FT TH IN DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. _ • <br /> TIPS LESS CO RD&LESS S 20FT TO CITY OF EVERETT&LESS ADD'L RNV TO A3.0 SHEET NUMBER WHERE n(� <br /> CITY OF EVERETT PER SWD REC AF 9104190362 DETAIL IS LOCATED <br /> 3. CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF 89 <br /> V <br /> THE WORK AS INDICATED ON ALL DRAWINGS.IF ERROR IN LAYOUT, <br /> 526 DIMENSIONS,OR DETAILS ARE FOUND BETWEEN ARCHITECTURAL, 6467 REGISTERED D <br /> STRUCTURAL,MECHANICAL,ELECTRICAL,CIVIL OR LANDSCAPE DRAWINGS ARCHITECT JU1V 14 20 4 <br /> CASINO RD CONTACT THE ARCHITECT IMMEDIATELY BEFORE PROCEEDING. <br /> 84TH ST SE PARCEL NUMBER L _ _ D, SECTION NUMBER <br /> 28051800201200 4 REQUIREMENTS FOR INSTALLATION OFCTION,MATERIALS ANDMATERIALS SHALL CONFORM AND BE AS 3 SEC ONSHEET NUMBER <br /> S BOCATEDRE TI Y JAM S Ew e OF.4 T <br /> w w GOVERNED BY THE EDITION OF THE CODE IDENTIFIED IN THE CODES AT OF WASH GTON i <br /> 99 CO W SECTION OF THIS SHEET. <br /> < Q 5. REFERENCING DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT _ <br /> C ¢_ = APPLICATION OF DRAWINGS OR DETAILS. DETAIL NUMBER <br /> A2 <br /> SIZE (GROSS) _ J A7.5 SHEET NUMBER WHERE IDENTIFICATION:PROJECT C <br /> 6. MATERIALS AND FINISHES LISTED ON INTERIOR AND EXTERIOR ELEVATIONS DETAIL IS LOCATED <br /> yQ� 8.05 ACRES IN ADDITION TO MATERIALE FOR GENERAL INFORMATION <br /> ANID FINISHES CONVENIENCE <br /> IE OF OR SPECCOETRACTOR. Emerson ES <br /> �\1 ELSEWHERE IN THE DOCUMENTS. <br /> �O 88TH ST SE 7. HEIGHT DIMENSIONS ARE GIVEN FROM FINISHED FLOOR WHERE INDICATED, 101 DOOR NUMBER BASED Portable 11 <br /> GOVERNING CODES OR RELATIVE TO DATUM NOTED ON DRAWINGS. ON ROOM NUMBER <br /> LU <br /> ❑ 1. WAC 51-50INTERNATIONAL BUILDING CODE,2018 EDITION 8. N.I.C.EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS.CONTRACTOR FOR <br /> J J IS RESPONSIBLE FOR COORDINATING INSTALLATION AND PERFORMING WORK <AA -WINDOW AND RELITE TYPE <br /> d Q 2. WAC 51-52 INTERNATIONAL MECHANICAL CODE,2018 EDITION AS REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT <br /> INSTALLATION. Everett Public <br /> F 3. WAC 51-54 INTERNATIONAL FIRE CODE,2018 EDITION a <br /> 2i 9. F.O.I.C.EQUIPMENT IS FURNISHED BY OTHERS AND INSTALLED AS PART OF NAME ROOM NAME Schools <br /> 4. WAC 5157 UNIFORM PLUMBING CODE,2018 EDITION THIS WORK.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE <br /> 101 <br /> S. WAC 51-11 WASHINGTON STATE ENERGY CODE WORK AS REQUIRED FOR INSTSALLATION. ROOM NUMBER 2018 EDITION AT <br /> 10.DO NOT SCALE DRAWINGS:CONTACT ARCHITECT FOR ANY NEEDED <br /> 92ND ST SE 6. 2018 EDITION NFPA STANDARD 72,13,13-D,13-R 2002 CLARIFICATION. <br /> NORTH MAINTAIN <br /> TYPE TAG 8702 7th Ave SE <br /> 7. ICC/ANSI A117.1-2017 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 11.CONTRACTOR SHALL INTAIN THE INTEGRITY OF THE VAPOR BARRIER <br /> MEMBRANE AT THE FLOOR SLAB,WALLS,AND ROOF.BACKER ROD,SEALANT, ^ <br /> AND OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND / REVISION IDENTIFICATION Everett, WA 98208 <br /> ALL EXTERIOR DOORS,WINDOW PENETRATIONS,AND OTHER AREAS OF L� <br /> POTENTIAL AIR INFILTRATION,INCLUDING STRUCTURAL,MECHANICAL,AND <br /> ELECTRICAL PENETRATIONS.THE CONTRACTOR SHALL REPAIR ANY DAMAGE REVISION CLOUD PERMIT r1 SET <br /> DRAWING INDEX TO VAPOR BARRIER OR REPLACE THEM PRIOR TO COVER AS APPROVED. 04/22/2024 <br /> PROJECT TEAM 12.WHERE EXTERIOR CONCRETE WALKS AND LANDINGS ABUT BUILDING,THEY <br /> GENERAL SHALL BE SLOPED AWAY FROM THE BUILDING AS NOTED,BUT IN NO CASE This drawing is: <br /> LESS THAN 1/8":12". 1.Copyright 2024 Dykeman,Inc. <br /> G01 TITLE SHEET,PROJECT INFORMATION INDICATES DIRECTION OF 2.The Architect's Instrument of Professional Service. <br /> B MAGNETIC NORTH 3.For use on this project only.Obtain Architect's B <br /> OWNER STRUCTURAL ENGINEER ARCHITECTURAL Written permission for any other use or reproduction. <br /> EVERETT PUBLIC SCHOOLS BRIGGS ENGINEERING,INC. As1.0 OVERALL SITE PLAN BUILDING CODE INFO NORTH PROJECT <br /> 3900 BROADWAY PO BOX 140537 AS1.1 PARTIAL SITE PLAN-PORTABLES <br /> OCCUPANCY: E <br /> EVERETT,WA NNIF GARDEN CITY,ID BRI ELECTRICAL(REFERENCE ONLY) 2024-010 <br /> Contact: JENNIFER COLLINS Contact: DEAN BRIGGS TYPE OF CONSTRUCTION: VB,NONSPRINKLERED(PORTABLE) <br /> Phone: (425)3864195 Phone: (208)87"200 El ELECTRICAL LEGEND AND DRAWING INDEX Permit#: B2404-056 ROLLED PLANS <br /> Fax: Fax: - Eo.2 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES BLDG SO FT: 887,ONE STORY <br /> Email: joollins@everettsd.org Email: bri sen ineedn E1.1 ELECTRICAL OVERALL SITE PLAN Site Address: 8702 7TH AVE PORTABLE 11 <br /> 1 @ r9 gg g g@msn.com E1.2 ELECTRICAL PARTIAL SITE PLAN BLDG HEIGHT: 15'-9" Owner: EVERETT SCHOOL DIST2 <br /> E1.3 LOW-VOLTAGE PARTIAL STfE PLAN <br /> Tenant: EMERSON ELEMENTARY <br /> E3.1 LOW-VOLTAGE FLOOR PLANS PORTABLE CLASSROOM CLUSTER: 2,661<6,000 SF App.Date: 4/25/2024 <br /> E7.1 ELECTRICAL DETAILS Permit Type: COMMERCIAL BUILDING <br /> E7.2 ELECTRICAL DETAILS OCCUPANT LOAD: 45 - Subtype: MODULAR BUILDING/PORTABLE <br /> E9.1 ELECTRICAL ONE-LINE DIAGRAMS Description: PORTABLE W/NEW FOUNDATION,RAMP - <br /> ARCHITECT RAMPS AND LANDINGS E10.1 PANELSCHEDULES &LANDING <br /> EVERETT FIRE DEPT.REVIEW 6��,� Date: <br /> DYKEMAN WELCOME RAMP SYSTEMS WELCOME RAMPS,LANDINGS AND STAIRS DEFERRED SUBMITTALS APPROVED Reviewed By: <br /> 1716 WEST MARINE VIEW DRIVE 2361 S 200TH ST <br /> EVERETT,WA 98201-2098 SEATTLE,WA 98198 1 OF 1 STANDARD PLANS AND DETAILS 1 FIRE ALARM uired ❑APPROVED WITH CHANGES NOTED Office Set _lob Site Set <br /> Additional Permits Are Req [I REVISE AND RESUBMIT <br /> Contact: ZACH HAM Contact: TERRI GORDON 28 X 32 PORTABLE PLANS For This Project To Include: ❑REIECTED: _ <br /> ❑SEE ATTACHED CHECKLIST/HANDOUT • <br /> Phone: (425)2593161 Phone: (866)935-9255 T-1 TITLE SHEET ❑ Plumbing ElS Sprinkler The issuance of a permit shall not PRINCIPAL IN CHARGE:I TJJ <br /> Fax: (425)259-5242 Fax: A-1 FLOOR PLAN,DOOR AND WINDOW SCHEDULE ❑ Mechanical ©Fire Alarm be construed as authority to violate, PROJECT MANAGER: 1 ZAH <br /> Email: zachh@dykeman.net Email: sales@weloomerampsystems.com A-2 SECTIONS,FASTENING SCHEDULE AND MATERIALS LIST cancel or set aside any provision of PROJECT ARCHITECT: <br /> A-3 EXTERIOR ELEVATIONS Ip Electrical the Everett Fire Code or other JOB CAPTAIN: AM <br /> A< DETAILS <br /> A-5 REFLECTED CEILING PLAN AND DETAILS applicable regulations or laws.The <br /> A M-1 MECHANICAL PLAN AND INFORMATION issuance of a permit based on DRAWING TITLE <br /> E-1 ELECTRICAL PLAN AND INFORMATION construction documents and other 'A <br /> ELECTRICAL ENGINEER F-1 PLANS,NOTES,MODULARFOUNDATION shall not the TITLE SHEET, PROJECT <br /> HARGIS ENGINEERS THESE DOCUMENTS HAVE NOT BEEN of ial <br /> from requiring the correction <br /> APPROVED FOR THE ISSUANCE OF °f errors. <br /> INFORMATION <br /> 1201 THIRD AVE,STE 600 PUBLIC WORKS,MECHANICAL,FIRE <br /> SEATTLE,WA 98101 SUPPRESSION,ELECTRICAL OR By: Da e: 2Si <br /> Contact: JEFF HOOVER PLHDMBING PERMITS. DRAWING <br /> Phone: (206)859-5396 <br /> Fax: <br /> Email: jeif.hoover@hargis.biz <br /> 1 2 3 4 5 <br />