My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8702 7TH AVE SE 2024 Plans 2025-11-06 (2)
>
Address Records
>
7TH AVE SE
>
8702
>
Plans
>
8702 7TH AVE SE 2024 Plans 2025-11-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/6/2025 11:06:00 AM
Creation date
11/6/2025 11:05:41 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8702
Permit
FA2408-003
Year
2024
Notes
FA Emerson Elementary Portable 11
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2408-003 <br /> Site Address: 8702 7th Ave Portable 11 <br /> Applicant: Convergint Technologies LLC <br /> Application Date:08/05/2024 <br /> Emerson <br /> cone rg�nt' <br /> convergInt ------------Description FAEmerso=Elementary Portable1lReview Date: 08/05/2024 <br /> IEverett Fire Dept.Notes: ` T 450 Shattuck Avenue South,Renton,Washington 98057 <br /> EVERET <br /> i(NFPA 72) I rvrRrTT Phone:425-272-2250 Fax:425-251-0949 <br /> EYERETi <br /> 'See Attached Fire Alarm System I Everett Fire Dept.Permit Review <br /> Acceptance Test Checklist. Status:Approved This document and the information/depictions osntained/shown <br /> Reviewed By:KBrown Is the exdusive pmpedy of Convergint Technologies LLC and shall <br /> •24 hour Battery Test-At the time of the I 08/05/2024 12:07:30 be handled as proprietary end confidential iofomlation and must be <br /> retumed upon request.This document cannot be reprotluSetl by any <br /> inspection/test provide proof verifying that the i PM ns without the written suthodzadon of convergent Tecnnologles LLC. <br /> E M E R S O N ELEMENTARY I panel has been doperating <br /> on t o on secondary power <br /> r(battery)for 24 hours.No other problems i <br /> shall be indicated on the panel. <br /> -Record of Completion-For all new I <br /> PORTABLE P 11 systems, Record of Completion is required i <br /> I to be entered <br /> ed into The Compliance Engine <br /> prior to permit final. <br /> (www.thecomplianceengine.com) <br /> ------------------- <br /> 8702 7TH AVE SE, EVERETT, WA 98208 <br /> SYMBOL LEGEND SCOPE OF WORK WIRE LEGEND <br /> SYM DESCRIPTION MODEL# MANUFACTURER BACK BOX THIS SCOPE OF WORK INCLUDES: ALL WIRING AND INSTALLATION METHODS SHALL BE IN COMPLIANCE WITH CURRENT RELEVANT <br /> EXISTING EST3 ANALOG ADDRESSABLE FIRE ALARM SYSTEM TO REMAIN. NATIONAL AND LOCAL ELECTRICAL CODE ARTICLES AND RELATED SECTION CODE REQUIREMENTS. <br /> Nnc�« NAC POWER SUPPLY-6A EBPS6A EST INCLUDED-17"H X 13"W X 3.5"D ADD NOTIFICATION DEVICES TO NEW PORTABLE. <br /> a SIGA-CCiS MODULE EXISTING POWER SUPPLY WILL BE USED TO SUPPORT ADDED HORN/STROBES. WIRING INSTALLATION NOTES: <br /> DOUBLE ACTION PULL STATION ADD HEAT DETECTORS ABOVE CEILING WITH REMOTE LED INDICATORS. 'LABEL ALL ZONE WIRES WITH ZONE NUMBER TAG AND DESCRIPTION. <br /> ❑r STANDARD SIGA-278 EST SINGLE GANG,2-1/2"DEEP ADD SMOKE DETECTORS FOR FULL COVERAGE. `LABEL ALL SIGNAL CIRCUIT WIRES WITH SIGNAL CIRCUIT NUMBER TAG AND DESCRIPTION. <br /> ADD A MANUAL PULL STATION. LABEL ALL NETWORK,ANNUNCIATOR AND 110 CONTROL CIRCUIT WIRING WITH CIRCUIT NUMBER <br /> O ADDRESSABLE ROR HEAT SIGA-HRD EST 4"OCTAGON BOX,1-1/2"DEEP TAG AND DESCRIPTION. <br /> Ra SIGA-SB4-STANDARD BASE `VERIFY WITH OWNER AND GENERAL CONTRACTOR THAT OPEN CABLE IS ALLOWED ON SPECIFIC <br /> Q ISOLATOR MODULE SIGA-IM2 EST 4"SQUARE BOX,1-1/2"DEEP,DOUBLE GANG DESIGN CRITERIA APPLICABLE STANDARDS AND GUIDANCE: SITE.(FPL,FPLP,RISER,OR 2 HOUR RATED) <br /> COVER NFPA 72,2016 EDITION 'WHERE REQUIRED,OUR DRAWINGS WILL NOTE WIRE OR PATHWAY REQUIRING SURVIVABILITY. <br /> 4"SQUARE BOX,1-1/2"DEEP,SINGLE GANG 2021 INTERNATIONAL BUILDING CODES WITH WA STATE AMENDMENTS SUBSTITUTE THE RELEVANT CABLE WITH AN EQUIVALENT CABLE COMPATIBLE WITH THE MEANS OF <br /> }( REMOTE ALARM LED-CEILING SIGA-LED EST COVER 2021 INTERNATIONAL MECHANICAL CODE WITH WA STATE AMENDMENTS SURVIVABILITY.THIS OFTEN INCLUDES;CI-C OR Cl CABLE(CIRCUIT INTEGRITY),CONCRETE <br /> 2020 NATIONAL ELECTRICAL CODE WITH WA STATE AMENDMENTS ENCASEMENT OR OTHER MEANS AS APPROVED BY THE AHJ.REFER TO NFPA 72 FOR FURTHER <br /> O STANDARD ADDRESSABLE SMOKE SIGA-OSD EST 4"OCTAGON BOX,1-1/2"DEEP 2021 INTERNATIONAL FIRE CODE WITH WA STATE AMENDMENTS INFORMATION. <br /> SIGASB4-STANDARD BASE <br /> HORN/STROBE-WALL MOUNT NON PLENUM: SINGLE COND.: PLENUM RATED: <br /> Ell COLOR:RED,MARKING:FIRE,LENS:CLEAR 757-BA-T EST 4"SQUARE OCCUPANCY/USE CLASSIFICATIONS: CIRCUIT DESCRIPTION (FPLR,FPL) (THHN,TFFN) (FPLP) <br /> HORN/STROBE-WALL MOUNT 4"SQUARE W/EST MODEL"GRSW-10" E-EDUCATION A ZONE/INPUT CIRCUIT BELDEN 5220UL <br /> EllCOLOR:WHITE,MARKING:FIRE,LENS:CLEAR G4AVWF EST WIRING PLATE (2)#16 AWG BELDEN 6220UL <br /> 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> DTK-2MHLP DITEK MOUNT IN ENCLOSURE-2.1"H X 1.4"W X DOCUMENTATION AVAILABLE TO CONVERGINT TECHNOLOGIES <br /> 0 24VDC SURGE SUPPRESSOR 24BWB 1.91113 ELECTRICAL DRAWINGS DATED 04-04-2024 C NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> Ja JUNCTION BOX BY OTHERS BY OTHERS - D MASS.NOTIFICATION NAC CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL DESIGNER OF RECORD <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> E DOOR HOLDER/CONTROL CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 612OUL TA NICET lu RIs <br /> CONTACT INFORMATION 2COND.14 AWG [2.430][23pF/FT] [2.4301[37pF/FT] FIRE-RIM SYSTEMS <br /> F FAN/HVAC SHUTDOWN BELDEN 5120UL (2)#14AWG BELDEN 612OUL ceRTIncATioN ztssass <br /> PROJECT MANAGER FIRE ALARM DESIGNER 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] EXPIRE DATE1-o1-20za <br /> KEVIN FREY TAYLOR HARRIS G FUTURE ADA NAC BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> FORVERIFICATION.PLEASE VISIT.NICETORGNERIFY <br /> 425_59KEVIN.1-5815 TAYL425_5 1-3607 CIRCUIT 2 COND.I4 AWG [2.430][23PRFT] [2.430][37pF/FT] <br /> KEVIN.FREY@CONVERGINT.COM TAYLOR.HARRIS@CONVERGINT.COM <br /> SALES REPRESENTATIVE H PHONE CIRCUIT BELDEN 5220FL N/A BELDEN 7pF/F] <br /> PETER LAVALIERE 2 COND.16 AWG SHIELDED [3.90][65.SpF/FT] [3.850][77pF/FT] Uo1_�/u",','-'' ��GtivvPl <br /> 206-483-5490 <br /> PETE.CAVALIERE@CONVERGINT.COM J 2 COND SPEAKER 16CIRCUIT BELDEN 5220UL (2)#i6 AWG BEL 0][37p6220UL <br /> 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] cone rg j nt <br /> L ELEVATOR CONTROL BELDEN 5120UL (2)#14 AWG BELDEN 612OUL <br /> SHEET LIST TABLE 12COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> SHEET NUMBER SHEET TITLE M AUDIO RISER BELDEN 5220FL N/A BELDEN 6220FL <br /> FA-0-1 COVER SHEET 2 COND.16 AWG SHIELDED [3.90][65.5pF/FT] [3.850][77pF/FT] <br /> FA-0-2 NOTES <br /> FA-0-3 NOTES N NETWORK COMMUNICATIONS BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> FA-0-4 SITE PLAN 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> FA-1-1.2 PORTABLE P11 <br /> FA-2-1 TYPICAL RISER P 24VDC AUX.POWER BELDEN 5120UL 2#14 AWG BELDEN 612OUL <br /> FA-4-3 DEVICE DETAILS () <br /> FA-5-2 CALCULATIONS 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> Q VESDA NET BELDEN 9841 N/A BELDEN 89841 <br /> 2 COND.22 AWG [240][12.8pF/FT] [240][12pF/FT] <br /> R REMOTE LED CIRCUIT BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> S ADDRESSABLE DATA SLC LOOP BELDEN 5220UL (2)#16 AWG BELDEN 6220UL <br /> 2 COND.16 AWG [3.850][24pF/FT] [3.850][37pF/FT] <br /> T1 ANALOG TWO-WAY COMM.CABLE N/A RATH RP66010001 <br /> 2 COND.18 AWG N/p' [2-HOUR CIC] <br /> T2 ANALOG TWO-WAY COMM.CABLE RATH 66120 NIA N/A <br /> 2 COND.18 AWG [2-HOUR] <br /> 7P ANALOG TWO-WAY POWER CABLE N/A RATH R66010001 <br /> 2 COND.18 AWG WA [2-11OUR CIC] <br /> U SUPPRESSION RELEASING CIRCUIT BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] jow-cm ION DATE to, <br /> H <br /> W SINGLE MODE FIBER NETWORK BUDGET SMXL02/SMXH]2:15/25 dBm <br /> 1 J0029M PI ISSUED FOR PERMIT TH <br /> 8.3p SM CONNECTOR:DUPLEX SC I A-Pt1 ISSUED FOR PERMIT TH <br /> X MULTIMODE FIBER NETWORK BUDGET MMXVR:10 dBm <br /> 50/125p,62.5/125p OR 100/140p MM CONNECTOR:ST <br /> Y TWO-WAY COMMUNICATIONS BELDEN 1583A NIA BELDEN 1585A <br /> CAT5E-(4)PAIR 22 AWG <br /> }� Z FIRE/SMOKE DAMPER INTERFACE BELDEN 5120UL (2)#14 AWG BELDEN 6120UL <br /> 2 COND.14 AWG [2.430][23pF/FT] [2.430][37pF/FT] <br /> O DRAWN BY TAYLORH. <br /> U NOTE:ALL LISTED RESISTANCE AND CAPACITANCE ARE CONDUCTOR TO CONDUCTOR.ALL PRaECT pesicxm: AYLORn <br /> W <br /> RESISTANCE VALUES ARE PER 1000 FEET. <br /> Q <br /> U <br /> Q <br /> U EMERSON ELEMENTARY <br /> F PORTABLE P11 <br /> 8702 7TH AVE SE <br /> M EVERETT,WA 9 208 <br /> x <br /> C4 <br /> N <br /> Oz COVER SHEET <br /> FIRE ALARM SYSTEM <br /> c� <br /> z <br /> WING. <br /> o FA-0-1 <br /> LL <br />
The URL can be used to link to this page
Your browser does not support the video tag.