Laserfiche WebLink
PROJECT INFO ABBREVIATIONS VICINITY MAP(NOT TO SCALE) z- -' <br /> DES PARCEL# <br /> ABV ABOVE HB H05EBI8 PROJECT SCOPE: o q <br /> NIGOLE ROHLINGER& 00410700300100 ADJ ADJUSTABLE HDWR HARDWARE L� � <br /> TYLER BARBERI APPROX APPROXIMATE HORIZ HORIZONTAL 'EXTERIOR SIDING REPAIRS. <br /> Zi BLK BLOCKING INT INTERIOR `NON-STRUCTURAL INTERIOR RE-FINISHING. o <br /> `BLW BELOW INSTALLATION OF NEW LOW-SLOPE ROOF RAFTERS. <br /> INSTL INSTALL 'RE-ROOFING 8 NEW RAFTER INSULATION. <br /> PRO_IFGT ADDRESS Rt <br /> BO BOTTOM OF MPR MANUFACTURE •STRUCTURAL FRAMING UPGRADES PER PLAN <br /> GAB CABINET MIN MINIMUM y 1020 39TH ST SE,EVERETT WA 98201 TO SUPPORT EXISTING INTERIOR BEARING kNALL5. 0 p <br /> G/C CENTER TO CENTER OG ON CENTER - v <br /> LEGAL DESCRIPTION• ENGINEER- <br /> CDR CEDAR PLY PLYWOOD LT-�HEWITT HEIGHTS ADD TO EVERETT BLK 003 1 STRUGUTRAL DESIGN GL CENTERLINE PT PRESSURE TREATED p <br /> Permit#: BW2104-0O1 <br /> 1-2-3-4 ENGINEER@F5G-DE5IGN.GOM COL COLUMN REM REMAIN THESE DOCUMENTS HAVE NOT BEEN Site Address: 102039THST FL�17r <br /> 206-660-2044 APPROVED FOR THE ISSUANCE OF Owner: BARBERI TyLER&ROHUNGER NICOLE y <br /> GONG CONCRETE REPL REPLACE PUBLIC WORKS,MECHANICAL,FIRE Tenant: [TenNamel <br /> SCOPE OF WORK GONT CONTINUOUS RO ROUGH OPENING SUPPREStION,ELECTRICAL OR App.Date: 4/6/2021 <br /> PLUMBING PERMITS. Proposed Use:RESIDENTIAL ALTERATIONS h <br /> Description: SFRrerocr-REPAIRAND REFRAMEOF <br /> REMOVE AND REBUILD ROOF GPT CARPET RMV REMOVE Additional Permits Are Req <br /> uired 4]OOF `J <br /> TR CENTER RU REUSE EXISTING ITEM d l <br /> For This Project TO In <br /> cue:VIA DIAMETER SD SMOKE DETECTOR Reviewed By: / Date0 L <br /> DN DOWN SHWR 5HOWER ® Plumbing Sprinkler 'officeSet Site Set <br /> _Fire/Planning set <br /> 05 DOWN SPOUT 55 STAINLESS STEEL © Mechanical Fire Alarm <br /> EX EQUAL T&G TONGUE&GROOVE GENERAL RESIDENTIAL PROJECT NOTES <br /> EXTG EXISTING TMP TEMPERED SubJectTo Field inspection <br /> EXT EXTERIOR TO TOP OF <br /> FIN FINISH TYP TYPICAL <br /> ANY 5FECIFIC REFERENCE TO CODES,RULES,REGULATIONS,STANDARDS,MANUFACTURERS INSTRUCTIONS OR REQUIREMENTS _ <br /> NOTES OF REGULATORY AGENCIES SHALL MEAN THE LATEST PRINTED EDITION OF EACH 15 IN EFFECT AT THE DATE OF SUBMISSION OR FIXT FIXTURE UNO UNLESS NOTED OTHERWISE BID UNLESS THE DOCUMENT IS SHOWN DATED. m <br /> 1.All work shall be done in conformance with the 2018 International Building code,2018 FTG FOOTING VERT VERTICAL FIRE PROTECTION m <br /> FV FIELD VERIFY YIN VINYL ALL NEW DETECTORS TO BE COMBINATION SMOKE AND CARBON MONOXIDE D u a <br /> Washington State Energy Code,Uniform Plumbing Code(UPC),National Electric MOTORS.(IRC R314)ALL NEW DETECTORS TO BE HARD-WIRED W TH BATTERY BACK-UP.(IRC R314)FX FIXED D W DETECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROV MANUFACTURER'S INSTRUCTION AND IN <br /> W1,1217 <br /> bS O <br /> Code(NEC)and applicable City and State of Washington codes and ordinances. W OOD <br /> 2.Provide smoke and G02 detectors per IRC Section 314 and 315. GWB GYPSUM ALL BOARD WIN WINDOW AccoRDANCE WITH AND NFPA 7z. ED DETECTORS SHALL BE INTERCONNECTED SUCH THAT WHEN ONE ALARM 15 ACTIVATED ALL REMAINING ALARMS i ARE ACTIVATED. °G <br /> o w <br /> 3.Best practices shall be taken In the Installation/CAnStHActlon Of materials •IN WOOD-FRAMED CONSTRUCTION,FIREBLOCKING SHALL BE PROVIDED IN LOCATIONS PER IRC R302.1 1. o w <br /> LOT COVERAGE 'WHERE THERE I5 USABLE SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR-CEILING ASSEMBLY, <br /> 4.Written dimensions on the Drawings shall take prec ¢ <br /> edence over scaled dimensions SYMBOLS& LEGEND w <br /> DRAFi5TOP5 SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FEET <br /> and/or contractor shall consult with ArchitecUDesigner (RC R3oz.127. o 5.Dimensions are from face of drywall to face of drywall unless noted othe wise EXISTING WALL(TO REMAIN) A-EX.HOUSE FOOTPRINT: 1931 5F u <br /> 6.Contractor shall verify all dimensions,conditions,etc.pertaining t0 the W GUTTERS 4 DOWNSPOUTS: Zork before CONTRACTOR SHALL PROVIDE'K-STYLE"GUTTERS AT ALL SLOPED ROOFS,UNLE55 DIRECTED OTHERWISE BY HOMEOWNER. <br /> proceeding. The ArchitecUDesigner must be notified of any variations from the TOTAL: 3F l q37 tf LAP ROOF SAVE FLASHING TO DISCHARGE INTO EDGE GUTTERS. PROVIDE APPROPRIATELY SIZED DOWNSPOUTS WHICH <br /> DISCHARGE INTO NEW 4°DIAMETER TIGHTLINE STORM DRAINAGE LEADERS WHICH ARE ROUTED INTO A SUITABLE STORM 0 <br /> dimensions and/or conditions shown on these Drawings. Any such variation shall be GROSS LOT SF 14,315 5F DRAINAGE SYSTEM OR OTHER APPROVED DRAINAGE D15CIIAKGE BMP SYSTEM. cc <br /> J <br /> W <br /> resolved y the Architect/Designer prior to proceeding with the work. . EXTG JOIST DIRECTION PERCENTAGE OF LOT _FA ROOFING ROOF FLASHING cc <br /> 7.Repetitive features not noted on the Drawings shall be completely provided as if S%J <br /> •CONTRACTOR SHALL PROVIDE METAL FLASHING AND OTHER WEATHER PROTECTION MATERIALS AS STATED IN IRC R903 AND 0 <br /> e Q <br /> R905. VALLEY FLASHING SHALL BE WITH STANDARD V-CRIMPED ENAMELED METAL. ROOF TO MASONRY CONDITIONS SHALL w <br /> drawn in full. Drawings Indicate general and typical details of construction. Wher HAVE STANDARD ENAMELED METAL STEP-FLASHING AND COUNTER-FLASHING AS REQUIRED. PROVIDE ALL DOOR,WINDOW, <br /> conditions are not specifically indicated,but are similar in character to details shown, X_XX„ CEILING HEIGHT DECK,LEDGER,AND OTHER FLASHING AS REQUIRED PER IRC. <br /> similar details of construction shall be used,subject to review and approval by the <br /> •FOR ROOF SLOPES FROM 2:12 TO 4:12 USING ASPHALT SHINGLES,PROVIDE DOUBLE UNDERLAYMENT(IRC K905.2.2) <br /> Architect/Designer. Refer to Drawings for openings,architectural requirements and DOOR EXISTING DOOR EXTERIOR FINISHES <br /> • WALL5 5HALL PROVIDE THE BUILDING WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE.THE EXTERIOR WALL <br /> dimensions.. WIN EXISTING WINDOW ENV EXTERIOR ELOPE SHALL INCLUDE FLASHING AS DESCRIBED IN IRC R703.THE EXTERIOR WALL ENVELOPE SHALL BE DESIGNED <br /> 8.Contractor and Subcontractors shall refer to Specifications or Scope of Work for AND CONSTRUCTED IN SUCH A MANNER AS TO PREVENT THE ACCUMULATION OF WATER WITHIN THE WALL ASSEMBLY BY <br /> PROVIDING A WATER-RESISTIVE BARRIER BEHIND THE EXTERIOR VENEER AS REQUIRED BY IRC R703.2. <br /> additional Information before proceeding on each stage of work. MAT-1 FLOOR FINISH <br /> 9.Homeowner shall do walkthrough with subcontractors,project manager,and/or INTEMRETATION5 <br /> X-1 MATERIAL FINISH THESE DOCUMENTS ARE IN PART DIAGRAMMATIC AND SUBJECT TO INTERPRETATION.THEY DO NOT NECESSARILY SHOW COMPLETE <br /> Architect/Designer to locate fixtures,accessories,Outlets,switches,etc. DETAILS OF CONSTRUCTION,WORK,OR MATERIALS,PERFORMANCE OR INSTALLATION,AND DO NOT NECE55APILY SHOW HOW <br /> 10.Actual fixtures and appliances may differ in appearance from those shown on CONSTRUCTION DETAILS OF OTHER ITEMS OF THE WORK MAY AFFECT ANY PARTICULAR INSTALLATION.ALL ASPECTS OF THE PROJECT <br /> MUST BE ASCERTAINED BY THE CONTRACTOR AND CORRELATED TO BRING THE PARTS TOGETHER A5 A COMPLETED WHOLE. FW <br /> Drawings CODE REFERENCES ANYDETAIL,DIMENSION,OR STATEMENT NOT COMPLETELY CLEAR TO THE CONTRACTOR SHALL BE REFERRED TO THE11. ENGINEERFOR INTERPRETATION.CONTRACTOR I5 REQUESTED TO PROVIDE CONSTRUCTION QUESTIONS IN THE FORM OF Aaterngs are representations 11 materials(such as tile). Site conditions and actual DOCUMENTED'RFI'(REQUEST FOR INFORMATION)DELIVERED VIA EMAIL AND INCLUDING ANY SUPPLEMENTARY PHOTOS,SKETCHES,materials may va y when Installed. 2018 RESIDENTIAL BUILDING GORE OR PLAN MARKUPS AS MAY BE USEFUL TO A5515T IN THE RESOLUTION OF THE QUESTION.12.Remove debris from the site as it accumulates to prevent unsafe conditions. EVERETT MUNICIPAL CODE EXISTING fA5-BUIL71 DIMEN Ions <br /> 13.Protect construction from weather as work proceeds. EVERETT ZONING CODE ALL DIMENSIONS ARE GIVEN TO THE FACE OF EXISTING FINISH MATERIALS <br /> 14.Existing materials are noted as"extg". New materials are not annotated as such. W <br /> Assume materials not called out as existing are new. DRAWING INDEX **ALL ELECTRICAL,MECHANICAL, /Q <br /> Al COVER PLUMBING,FRAMING INSTALLED V <br /> A2 5ITE PLAN OR ALTERED WITHOUT PERMITS <br /> A3 A5-BUILT/LOWER LEVEL FRAMING PLAN ENERGY CODE COMPLIANCE NOTES, OR INSPECTION OR APPROVAL <br /> A4 A5-BUILT/MAIN FLOOR PLANMUST BE UNCOVERED FOR <br /> A5 A5-BUILT/ROOF FRAMING PLAN TABLE R402.1.1 <br /> Ab AS-BUILT EXTERIOR ELEVATIONS <br /> INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT- INSPECTION**/ <br /> 5-1 MAIN FLOOR FRAMING-UPGRADES CLIMATE ZONES AND MARINE 4 <br /> Fenestration U-Factorb 0.30 <br /> 5-2 ROOF FRAMING-UPGRADES Skylight'U-Factor o.s0 <br /> Calling R•VeluB• 4g JOB NAME: BARBERI <br /> Wood Frame Walla,°111 21 IN JOB NO.; •••• <br /> Floor R-Value 30 <br /> DRAWN BY: BAYLEE <br /> Below-Orade°•b Wall R•Valua 10/15/21 Int*5TB <br /> Slabdr R-Value 8 Depth 10,2 ft PRINT DATE: 2/3/2022 <br /> FOR: PERMIT <br /> TRADE WALK:9/17/2020 <br /> •ADDITIONS TO AN EXISTING BUILDING,BUILDING SYSTEM OR PORTION THEREOF SHALL <br /> CONFORM TO THE PROVISIONS OF THIS CODE AS THOSE PROVISIONS RELATE TO NEW CONTRACT: +/••/+»• <br /> CONSTRUCTION WITHOUT REQUIRING THE UNALTERED PORTION OF THE FX15TING <br /> BUILDING OR BUILDING SYSTEM TO COMPLY WITH THI5 CODE(W5EC R502). REVISIONS: <br /> •ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS <br /> OF THE CODE FOR NEW CONSTRUCTION.ALTERATIONS SHALL Be SUCH THAT THE <br /> EXISTING BUILDING OR STRUCTURE 15 NO LE55 CONFORMING TO THE PROVISIONS OF <br /> THIS CODE THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION <br /> (W5EC R503.1). <br /> •BUILDING ENVELOPE ASSEMBLIES THAT ARE PART OF THE ALTERATION 5HALL COMPLY <br /> WITH W5EC TABLE R402.1.1 MINIMUM PRESCRIPTIVE REQUIREMENTS FOR <br /> NEW CONSTRUCTION(W5EC REDS.1.1). <br /> •EXISTING STRUCTURE NEED NOT COMPLY WITH THE REQUIREMENTS FOR NEW CONSTRUCTION <br /> PROVIDED THE ENERGY USE OF THE BUILDING IS NOT INCREASED AND THE EXISTING SHEET: <br /> ROOF,WALL OR FLOOR CAVITY 15 NOT EXPOSED.IF EXISTING CEILING,WALL OR FLOOR <br /> CAVITIES ARE EXPOSED DURING CONSTRUCTION,TH05E TO BE FILLED WITH INSULATION. <br /> 2x4 FRAMED WALL5 SHALL BE INSULATED TO A MINIMUM OF 115 AND 2xG FRAMED sa <br /> WALLS SHALL BE INSULATED TO A MINIMUM OF R-21(W5EC R503.1.1), Al <br /> CITY OF EVERETT <br /> iEWED FOR PERMIT <br /> Page: 1 of 7 <br />