Laserfiche WebLink
F <br />C <br />I <br />C <br />i <br />0 <br />7 <br />7 <br />l�. <br />I <br />5 <br />2 <br />DESIGN CONDITIONS <br />PER ASME B31.1 - POWER PIPING <br />DESIGN TEMPERATURE <br />225 F <br />DESIGN PRESSURE <br />10 PSIG <br />CORROSION ALLOWANCE <br />N/A <br />RADIOGRAPHY <br />NONE <br />PNEUMATIC TEST <br />BETWEEN 12 PSIG TO 15 PSIG <br />ISO VIEW LAYOUT <br />SCALE: NONE <br />on <br />3 <br />7 INSTALL CONCRETE ANCHORS PER MANUFACTURERS <br />SPECIFICATIONS. IF NO ANCHORS ARE SPECIFIED <br />C1-4 USE 1 IN DIA X 6 IN LONG POST INSTALLED <br />ANCHORS SUCH AS MC #91578A730. <br />F <br />GENERAL NOTES <br />aaUI <br />MAY 15 2025 D <br />CITY OF EVERETT <br />Permit Services <br />Permit#: <br />M2503-111 <br />Site Address: <br />1313 75TH ST SW BLDG A <br />Owner: <br />MIDDLE EARTH HOLDING LLC <br />Tenant: <br />HELION ENERGY <br />Apt. Date: <br />3/31/2025 <br />Permit Type: <br />MECHANICAL <br />Subtype: <br />COMMERCIAL MECHANICAL (PLAN REVIEW <br />REQUIRED) <br />Description: <br />INSTALLATION OFTANRS, FAN, <br />C IPING 7 <br />Reviewed By: te: _7 � 25 <br />Office Set _Job Site Sew <br />IF <br />BREAK SHARP EDGES AND CORNERS, EXCEPT AS SHOWN. <br />SCALE DRAWING AND/OR ANALYZE DATASET FOR NON- <br />CRITICAL DIMENSIONS NOT SHOWN. <br />WELD PER ASME BPVC, SECTION IX. ALL FLANGES TO HAVE <br />HOLES STRADDLE CENTER LINES. <br />25�ALL SURFACES UNLESS OTHERWISE SPECIFIED <br />PNEUMATIC TEST - PRESSURE SHALL NOT BE LESS THAN <br />1.2 NOR MORE THAN 1.5 TIMES THE DESIGN PRESSURE OF <br />THE SYSTEM. INCREASE THE PRESSURE GRADUALLY TO 1/2 <br />OF THE TEST PRESSURE AND THEN INCREASE IN STEPS OF <br />1/10 THE TEST PRESSURE UNTIL THE REQUIRED TEST <br />PRESSURE HAS BEEN REACHED. THE PRESSURE SHALL BE <br />CONTINUOUSLY MAINTAINED FOR A MINIMUM OF 10 MIN. <br />REDUCE THE TEST PRESSURE TO THE DESIGN PRESSURE AND <br />EXAMINE FOR LEAKAGE USING A SOAP BUBBLE OR <br />EQUIVALENT METHOD. ECEPYE <br />R MAR 1 1 1121 C <br />ITY OF <br />FLAG NOTES CPermit ServRETf <br />i <br />PURCHASE LONG AND FIT ON SITE FOR FIELD WELD. <br />-/ DIMENSIONS GIVEN ARE THEORETICALLY EXACT <br />\ M/L, F/D DIMENSIONS. PROVIDE ADDITIONAL MATERIAL FOR <br />`\ FITMENT ON SITE. <br />I <br />I <br />I I \ <br />o X <br />4 <br />\\ \ <br />Additional Permits Are Required <br />\ For This Project To Include: <br />Plumbing 0 Sprinkler <br />Mechanical [3 Fire Alarm <br />(Electrical <br />5 I 4 <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />CUSTOMER APPROVAL <br />BY: DATE: <br />3 <br />2 TORQUE TO 200 FT-LBS. FOR BRAY WAFER VALVES. <br />D3-4,F/D <br />3 TORQUE TO 75 FT-LBS. FOR BRAY WAFER VALVES. <br />B3-4,F/D <br />q LEAVE UNFINISHED. <br />T/B <br />5 TORQUE TO 110 FT-LBS. <br />B1-4,F/D <br />6 TORQUE TO 60 FT -LB; <br />B3-4,F/D <br />UNLESS OTHERWISE SPECIFIED, <br />ALL DIMENSIONS ARE IN INCHES <br />AND DEGREES. <br />DIMENSIONS AND TOLERANCING ARE <br />APPLICABLE IN THE UNRESTRAINED <br />CONDITION FOLLOWING WELDING <br />AND FINAL MACHINING. <br />TOLERANCES: <br />FRACTIONS DECIMALS ANGLES DATE <br />.XX ±.03 03/06/25 <br />.XXX ±.010 <br />DRAWN BY <br />JP <br />THIRD ANGLE PROJECTION - USA <br />FINISH: I SCALE I JOB # <br />F/N 4 NTS PO #P8591 <br />F% <br />FOR ALL 1 1/8 - 7 THD ROD. <br />FOR ALL 7/8-9 THD ROD. <br />WINDSPEED <br />TITLE: <br />INTERCONNECT PIPING <br />HELION <br />DRAWING # I REV I SHT <br />HELION-INTERCONNECT-PIPING 1 -1 7 <br />1 <br />E <br />C <br />LO <br />i <br />V <br />