|
9 � 8 � 7 � 6 � 5 � 4 � 3 � 2 � 1
<br /> I�LVI+�� II�S'T�.LL�.�..TI�N RE VIREMENTS
<br /> � FIRE PROTECTION INC.
<br /> � 1730 Gibson Road
<br /> ��u����r Everett, WA. 98204
<br /> F�R�1C�iC�' J-�C7�. h1USfi 8E A�tIF�If�UM NOT PERF�11T7E[3 0 ',
<br /> , , ����iraU r��ou�r�� I a��� ����� hva�c 425-290-9600
<br /> ,
<br /> ,
<br /> _
<br /> � � _ � ��T�CTQR �"" SIIFPLY DIFFtJSERS � C�1LIP�G 4� �
<br /> .___ � � '
<br /> �" �"`��»-� � . p .3�"� �' �€ U L .., , ,�„v
<br /> _ ,,.�. . __ . .. , . .. .. , .
<br /> r ; ;, � ;
<br /> � C�!LIt�G G?ID �,�.� `� l����1 r, �
<br /> _C=.A�7�a��r� �,�� �� �: _� ,
<br /> �t �� �� 3w � �:�; �
<br /> }"�1���(��V�.,.,���. .-,.. �,
<br /> , ''� PEFtM17TEC} 12" .�
<br /> .�•�;
<br /> :��>;>� .
<br /> ! . .
<br /> . ��
<br /> ��JiC� .
<br /> �� WERE �h1AX ��l�.t�rrP�, _
<br /> '•1� ,�tax H�;�t��'-�2",��� i�QT PERMITT�D � � . , ��'
<br /> � �j9iI�44�'lGHT-82"A�`� HERE � .
<br /> ;�euy
<br /> PERMITT�[? :-,,�:,:,; ' �0�$�a�L?�
<br /> .�,�:�,;, ,
<br /> HERE Q O
<br /> D � : ,.:. � ���� >: .• �:�tx�'r'c��f�,a=1n�j�,E � ` ry R.�Y �T
<br /> . � . � � . , `. r '" r� - `" � _ � .
<br /> � � � � �' � �; , c �` , f, - - �(������. �
<br /> - �: :' � -
<br /> ��"�rl�;�AFF 4 � l. � �� � . ,. -. �� �'�}�
<br /> . , r .
<br /> �2"'��ll�!t�FF ��1�� ��� � � ` : � - ,,,, � ,
<br /> [� � .::�-_. > ��_�:tt,nJf: �' � Is1�
<br /> FIRE � WT � ( . - 1 �'$}[,Ur�`i��ii-9 �..�-" ; �
<br /> 66" AFF C�Q"AFF � . j �.r
<br /> �
<br /> � : �,;, i:,11:�tr�:�rt' �{r '�.
<br /> k�tC3C.�tf�4 �,.�13i1.�{(�{� _i '"7 Y ���� �
<br /> ���� � 1f4�t.li't:ii l, •
<br /> G� , �`l�:fl.��[II�E�I a31I� �f1�JiUft• �� ,� . �
<br /> 48" RFF �i ���v�.n T � ', � G�P�+ �
<br /> � �
<br /> g.,.��t€�f:;��vrr t�ussir��.ve I
<br /> ;•.., '�<..',s,� A, F33+:S�iC:'i.'1t
<br /> FINiSHED FL�?C?R ; � .: ` -y. '� #�.4�'�
<br /> ,
<br /> _ _ _
<br /> � � .� �
<br /> . , r Y
<br /> e. � :. .. � s,r,.��>. •.; -
<br /> I
<br /> T � . � ?� �
<br /> . . . . . . . ' ' y - 4 II
<br /> G
<br /> INSTALLATION NOTES SYiVI�OL LEGEND �COPE O�,VIIORMC I �� ��
<br /> . F��
<br /> �
<br /> 1) Prior to calling for inspection, the installer shall provide documentation to the local SYMBOL DESCRIPTION PART # MF� QT� Fire �41arm Tenant Improvernent per plan ; install (°i) new fiire � �'�tir��
<br /> AHJ st�tin that the s stem has been installed tested, evaluated and confirmed to be in alarm rernote power supply � ('92j occupant notification devic�s. ���-Y �� ���,���,�Q
<br /> J Y �
<br /> accordance with all governing codes and the approved plans. The Fire Alarm System RPS 6 AMP NAC PaWER SUPPLY W/SYNCH 5495 SILENT KNIGHT 1 a�V�� ���
<br /> Relocate 1 exi�tin srn�ke d�tector to the nev� anitor closet to ������'��°������n�
<br /> in�tailer shall complete an NFPA72 Record of Completion (NFPA72 10.18.2.1.1). The � � 9 J #��_��,��,�
<br /> cornpleted Record of Completion shall be provided to the AHJ inspector at the time of SO PHOT� DETECT�R, INTELL. ADDRESSABI�E FSP-851 NC?TIFIER E pro�ide detection coverage for the nevv fire �larm remote power
<br /> insp�c#ion (NFPA72 10.18.2.1.2.4). supply.
<br /> FacP EXISTING FACP NFS2-3030D NOTIFIER E
<br /> 2) �nstructions for the operating, testing and maintenance of the system, along with EVAC EXISTING VOICE EVAC AMPLIFIER NFV-25/50 NOTIFIER E The speaker por�ion of the new speaker/strobes wili be wired as � �
<br /> �
<br /> . record drawings otherwise referred to as ("as-built") and equipment specifications shall 0 in/out off the existing speaker circuit setv�ng this flr�or (7th N W
<br /> � r > >
<br /> ` � be provided at an approved location (NFPA72 10.18.2.3). Floo�). > � � � �
<br /> Sp SPEAKERISTROBE WALL, MULTI-CANDELA WHITE SQUARE E50-24MCW-FW WHEELC�CK 1 ' w � �n
<br /> ##CD #.#'V1/ �
<br /> � W �m,� � � W
<br /> 3) Ail systems and devices shall be installed and tested per the manufactures listing The Strobe portion of the speaker/strobes will be wired to the � � � � �
<br /> and the authori havon urisdiction NFPA72 10.14.2.1 . Label all device locations Sp new remote power supply being installed in ttae janitors closet. � � a v =
<br /> � g � � � ##CD #.#W SPEAKER/STROBE, M-C, WHITE, GEILING ET90-24MCC-FW WHEELOCK 7 � � �, � c�
<br /> 0 0 'd � or � N �
<br /> ��nta�nir�g El�L r����tors. � c� � ,� � �
<br /> � / �iny w rk utsi e of the tenant improvement area is specifically � � o � N a
<br /> �� F�4�� � al� ��r�ri��� �ower Suppiies �E(�UIRE a DEDiCATED 120VAC 20amp circuit. /�� ##CD STROBE, EXCEDER 24V, M-C, �IVHITE, CEILIN� STWC STWC 6 excluded. � Q � � � o
<br /> r� r���ic� p l���� in t h� F��� s h�i� dir�c t personne l to t he lo�a tion o f t he e lec trica l pane l m � o � � �
<br /> ���� i� �upplyi�� ���I�d�T�� pow�r to the system (NFPA72, Section 10.5.5.1). The � � � � � � �
<br /> '�E��C�T'�� �irc�ait break�r tha# serve� the fire alarrr� system shall be Labeled and SINGLE LINE FZISEF� DIAGRANi OPEF�T'IOIVAL. MATRI�C � � ; W ,� �
<br /> ���ur�� ag�i�st tar�pering with a RED breaker lockout (NFPA72, Section 10.5.5.2). � " � `� -' �-
<br /> �5 C D [}.1 2 5 W 9 5 C D 1 W 9 5 C D 1 W 1 5 C D
<br /> REVISION RECORD
<br /> �) �+�li �aur�fed strobes shall be placed 80" minimum to 96" maximum above floor � � DATE / DE�CRIPTION
<br /> SP - SP - - � SP � - -- m - � - - SYST'EM OUTPUTS
<br /> (e��l. �IFPA7� 1�.5.A�.1 & 2). V14all mounted strobes shall be sized in accordance with �,��• • • • • • • • • • • • • • • • • • • • • • • • •/ �• • • • • �
<br /> � � . Required Fire Safety Control
<br /> (�l�PA7� T'a�l� 18.�.463.1(�)e �eiling mounted strobes shall be placed and sized in �"o��o� o��o`ti o�ryo 00 : I Notification
<br /> ��c�r�anc� with�NFPA72 Table 18.5.4.3.1(b). `�ry o `�ry o ��ry o �ry : I Control UnitAnnunciation
<br /> ��• Q�• ��• y� : �
<br /> .
<br /> 6) VVh�n �O�E tha� two notification appliances are visible at the same time whether � y � : � � ��,�m°r � ��"i��� �-���
<br /> tf�ey �re in #he sarr�e room or adjacen# space within the field of view the flash of those • � y�- � �° o' ' FA 0.0 COVER SHEET
<br /> �#r�b�� shall be synchronized (NFPA72, Section 18.5.4.3.2 3 & 4 . � 95CD 1W 15CD 30CD 15CD 1W 15CD 30CD 0.25W 15CD 15CD 15CD Q.2�W : � RPS v o< � •� �'"� �
<br /> ( ) ( � \ / \ / \ / \ / \ /
<br /> � �o` �c �� �� �`y �a� � � FA 1.0 FIRE a4LARM `f'.I.
<br /> SP - - -- - Q - - - - - Q - - - - SP - - - - Q - - - - SP � � _... � �_ r ..� _ Q _ -�- . SP - � ��� � u`° a a � � o
<br /> . . . . . . . . . .� � . . . . . . . . . .� � . . . . . . . . . . . . . . . . . . . � �. . . . . . . . . . . . . . . . ./ �. . . . . . ./ � . . . . � . . . . ..� `� <`''� ,� ��Q���i� Q��
<br /> �j P'u!I stats�rr� shal! be placed betvveen 42 and 48 inches above floor level. Devices o°' co o� �� o`D^ �� o`" ��h o�' oti o� � ' ` y ��° � ° �
<br /> � � O o o O O � O O Q e o � : DEQICATED 12QVAC �� �'p� wo ` �/js Q' os
<br /> � �hail be r�d i� ��lor (iCC A117.1 309 � fdFF�A 72 17.14.5 ) � o ,� ,� ,� o ,� �. o ,� ,� � � ; . 20AMP CIRCUIT �.�y � � °m w° � ��
<br /> y��^ �� �� y��� e� ���� `�' �� �je�� ; � �F � � .�a� ��'�m��w ��
<br /> �) �ir� ����rn circua#� t� be ins�ailed/secured/terminated in accordance with NEC, NFPA �Q� y � �Q� � �Q� � � �Q� ' ; ���'����.,�'�'�y�o '
<br /> sI Uj h, �` 9 Uj '�, w
<br /> � • O O O � �� �Q .`O` Q�'
<br /> 72, i�� ��� �c���� AHJ requirements & standards. • • 7TH FLOOR �F F���.�� �� `'w` �
<br /> CIRCUIT LINE TYPE DETAIL .v._...�,�.m � � � � � � .��a..�..a m m �- .___�� �.�__.. � ��._v..�_�,� a���_ffi�� � �m : : � � � � � n a _
<br /> �° v° v° �`.�'.� w'` o
<br /> m . ' 1 ST FLOOR m � � F � � `'� „�
<br /> 1 , , �, w, �s ��i ��i �y w��C��P
<br /> • . Q Q � ����`��`�e Q
<br /> . . f W • • • • • O • • • • • •
<br /> I
<br /> " " • ' • • • • • • ' • • • SYSTEMIFIPUTS A B C D E F G H
<br /> ������i4�" �.�9`�9�w `�''�'�='� �s��°���� �.� �1'�� (E) AMP 2 Smoke'Detectlors Boxes X X )C X �
<br /> � � �
<br /> 3 Heat Detectors � X � X 3
<br /> � � . . 9 , , , a ��� . , ����•������i�.a����� ���p����� �°���-��-�� 4 Waterflow x x X X 4 ��ALE : 1/�" � �'
<br /> ,-(�
<br /> �� �` � � � � ,���,, ����������� ���h� 5 SprinklerControl Valve X X 5 �
<br /> ��/'� r�� ` "������
<br /> `�,_ 6 Fire Alarm AC Power Failure � X 6 �A��o �.��Q'�'�7
<br /> �- `� �_# ��'��I��� �'�'�,�� ;��.��"��1����� 1��^�� � ��b����'
<br /> -- .-.-- �.�. �-� ���-�- -- _ 7 Fire Aiarm S ystem Low Battery X X 7
<br /> �-(� a�.h� �`�'��".al�� �=r��r��'���i�i`C�� �'r�1�; ��1,�"�(�`-��,1�7"i�'��1+�;�"�"�t..�C'� �'�:9.y��'��°�' PR�JE{a1" �!�►I�/IE
<br /> - (E) FACP 8 Open Circuit X X 8
<br /> 9 Ground Fault )( X 9
<br /> � � �� 10 Notification Appliance Circuit Short j( X 10
<br /> ����/ Permit#: E1712-039
<br /> Site Address: 2707 COLBY AVE 7TFf FLOOR
<br /> 1 ST FLOOR A B C D E F G H
<br /> .���� � '� ��'�J Qwner: SKQTDAL MUTUAL LLC �. .�---� � � _._a_.,___ � � . ._.._�__�.._m,�� � ..._.m.._LL_�__u_�.�.�.,� � ��� � � � �. �-- �_- --� ,.�� -- � � -- a �� m m �� �' �
<br /> .�w.a��. .�_ �e _ �..�. ._�.�9. u wa..�._ � ��.�_
<br /> _._.�,�,._. .�..�._x. ...�.. �..._ . , � �
<br /> Tenant: HQR y
<br /> CIT�'O� EVE�tET�' a��. ��t�: u/6/zav ( , BATTERY & CII�CUIT' CALCULA�'IOIVS � � �
<br /> _ �8
<br /> � � � `�� Proposed Use: CQMMERCIAL � � � n
<br /> � � � �
<br /> Description: FIRE ALARM TI-HDR
<br /> REVIEWED AND AELEA$�p � � � �
<br /> FOR CONS7Rt��^"-��..
<br /> � �Y Battery Calculations for Panel: RPS Circuit Calculations Panel: RPS Card: 00 Circuit:SIG1 Circuit C�Iculations Panel: RPS Card: 00 Circuit:SIG2 Li� O � �
<br /> �v��� I . � �
<br /> r� F��� d� 1V���1Y Part No.5495-6 AMP NAC POWER SUPPLY W/SYNCH CircuitName: SIG1 CircuitName:SIG2 � � �
<br /> ^ i' n -- �
<br /> �UBJE I'�
<br /> �� �'� ��.� 'flfll Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage:2.00OOA Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 2.00OOA � � �
<br /> Part No: Qt Descri tion Standb Total Standb Alarm Total Alar
<br /> Panel Equipment Cable: 16/4C TWISTED FPLR#16 Cable: 16/4C TWISTED FPLR#16 � � � �
<br /> E E TENDER PANEL MAIN MOTHER BOAR
<br /> D 75.00OOmA 75.00OOmA 205.00OOmA 205.00OOmA Calculations based on Running Total Length. Calculations based on Running Total Length. � �
<br /> 54958 1 5495 POW R X �
<br /> ��y.�, Total Panel Stby 75.00OOmA Total Panel Alarm 205.00OOmA Design Criteria:Ambient temperature: 167°F Max. operating voltage drop: 10% Design Criteria:Ambient temperature: 167°F Max.operating voltage drop: 10% � �
<br /> Y� � a Peripheral Devices Device Part No A liance Desc Distance Current Volta e Volta e Dro Device Part No A liance Desc Distance Current Volta e Volta e Dro
<br /> ������� �y �T.9 -24 CG�W 1 SPEAKER/STROBE, M-C,WHITE, CEILING Notification O.00OOmH O.00OOmA 92.00OOmA 92.00OOmA 5495 Panel 20.4V 5495 Panel 20.4V
<br /> �' ��� r :�_,�.�.; b ,.� r � )
<br /> ET90-2 MCC N� 3 SPEAKER/STROBE, M-C,WHITE, CEILING (Notification} O.00OOmA O.00OOmA 220.00OOmA 660.00OOmA 001 ET90-24MCGFW SPEAKER/STROBE, M-C, WHITE, CEILING, 15CD 10'-0 60.00OOmA 20.3315V (0.0685� 001 STWC STROBE, EXCEDER 24V, M-C,WHITE, CEILING, 15CD 23'-0 61.00OOmA 20.2738V (0.1262�
<br /> � . ET90-2�MCGFW _2 SPEAKER/STROBE, M-C,WHITE, CEILING (Notification) O.00OOmA O.00OOmA 60.00OOmA 120.00OOmA 002 STWC STROBE, EXCEDER 24V, M-C,WHITE, CEILING, 15CD 19'-0 61.00OOmA 20.2126V (0.1189V) 002 ET90-24MCGFW SPEAKER/STROBE, M-C, WHITE,CEILING, 95CD 50'-0 220.00OOmA 20.0293V (02445�
<br /> � � STWC 5 STROBE, EXCEDER 24V, M-C,WHITE, CEILING (IVotification) O.00OOmA O.00OOmA 61.00OOmA 244.00OOmA 003 STWC STROBE, EXCEDER 24V, M-C,WHITE, CEILWG, 15CD 9'-0 61.00OOmA 20.1126V (0.1089� 003 ET90-24MCGFW SPEAKER/STROBE, M-C, WHITE,CEILING, 95CD 64'-0 220.00OOmA 19.8541V (0.1753�
<br /> �� _ S7WC 1 STROBE, EXCEDER 24V, M-C,WHITE, CEILING (Notification) O.00OOmA O.00OOmA 85.00OOmA 85,OOOOmA 004 ET90-24MCGFW SPEAKER/STROBE M-C WHITE CEILING 30CD 35'-0 92.00OOmA 20.0144V 0.1982V 004 E50-24MCW-FW SPEAKER/STROBE,WALL, MULTI-CANDELA WHITE SQUARE, 15CD 33'-0 60.00OOmA 19.8347V (0.0194� SFlEET DESCRIPTION
<br /> �� �E50-24MCW-FW � SPEAKER/STROBE,WALL, MULTI-CANDELA WHITE SQUARE (Notification) O.00OOmA O.00OOmA 60.00OOmA 60.00OOmA 005 STWC STROBE EXCEDER 24V M-C WHITE CEILING 15CD 20'-0 61.00OOmA 19.9192V 0.0953 170'-0 561.00OOmA
<br /> ��� _ Total Peripheral Stby O.00OOmA Total Periph Alarm 1261.00OOmA 006 ET90-24MCGFW SPEAKER/STROBE M-C WHITE CEILING 15CD 31'-0 60.00OOmA 19.79V 0.1292V Total Current: 561.00OOmA I FIRE AL�RM
<br /> ��►-� � 007 STWC STROBE EXCEDER 24V M-C WHITE CEILING 30CD 29'-0 85.00OOmA 19.6862V 0.1038V (Total VDrop Percent:2.77%) Total Voltage Drop : 0.5653V TENANT IMPROVEM�NT
<br /> � Total Standb Am s 75.00OOmA Total Alarm Am s 1466.00OOmA 008 COVER SHEET
<br /> �,�� Y P P STWC STROBE EXCEDER 24V M-C WHITE CEILING 15CD 27'-0 61.00OOmA 19.612V 0.0742
<br /> " ��� ET90-24MCGFW SPEAKER/STROBE M-C WHITE CEILING 95CD 21'-0 220.00OOmA 19.5668V 0.0452V
<br /> � � Standby time: 24 Hrs 1.8Ah 192'-0 700.00OOmA '
<br /> � SWE�T' NUII�BEFt
<br /> � Alarm time: 5 Min 0.122Ah Total Current: 700.00OOmA /
<br /> � Battery requirement: 1.922Ah (Total VDrop Percent:4.08%) Total Voltage Drop : 0.8332V �
<br /> � Compensation Factors-Standby: 1.2 Alarm: 1.2 Requirement with compensation: 2.307Ah •
<br /> � . �
<br /> 9 I 8 � 7 ( 6 I 5 I 4 I _ _�_��.�d..�._�_3.�� _ � . z _ � �
<br />
|