My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6605 HARDESON RD 2017 HOGLAND TRANSFER Plans 2022-12-06
>
Address Records
>
HARDESON RD
>
6605
>
HOGLAND TRANSFER
>
Plans
>
6605 HARDESON RD 2017 HOGLAND TRANSFER Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 8:13:01 AM
Creation date
5/4/2018 1:09:57 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
6605
Tenant Name
HOGLAND TRANSFER
Permit
M1706-048
Year
2017
Notes
REMOVE AND REPLACE ONE 3 TON GAS ROOFTOP UNIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> SEISMIC ROOF CURB ATTACHMENT DETAIL GAS PIPING REGULATOR DETAIL HVAC ABBREVIATIONS HVAC LEGEND HVAC NOTES <br /> � AFF ABOVE FINISHED FLOOR � � INLINE EXHAUST FAN(S) 1• DUCT iNSULATION TO MEET THE REQUIREMENTS OF SECT- D <br /> 2 BDD BACKDRAFT DAMPER ION C403.2.8 OF THE 2015 WSEC AND SECTION 604 OF <br /> �/ BTUH BRITISH THERMAL UNIT PER HOUR THE IECC (INTERNATIONAL ENERGY CONSERVATION CODE). <br /> T� � 4"\ OO CD CEILING DIFFUSER <br /> 1000 ROOFfOP EXHAUST FAN 2. SMOKE DETECTOR(S) INSTALLED IN MAIN RETURN AIR <br /> �` \ � O CFM CUBIC FEET PER MINUTE DUCTS PER SECTION 606 OF THE 2015 IMC. HVAC SMOKE <br /> I <br /> I Y CU CONDENSING UNIT <br /> q�� �� \ DUCT DETECTORS SHALL SHUT DOWN POWER TO THE <br /> � I� DB DECIBEL UNIT UPON ACTNATION AND A "SUPERVISORY" ZONE SHALL �� <br /> a � 1�2 DH DUCT HEATER SIDEWALL EXHAUST FAN BE INITIATED AT FIRE ALARM PANEL UPON SMOKE DUCT ��n ���;;; �7r—,, <br /> �� <br /> DN DOWN DETECTOR ACTNATION. IMC SECTION 606.2.1. � � ��t I � � ��� <br /> 3" � � 5 EC EVAPORATOR COIL 1 v I � <br /> � � O EER ENERGY EFFfCIENCY RATIO 3. DUCTWORK-MAINTRUNK {S R-4.2 IN CONDITIONED SPACES �J <br /> �� � EF EXHAUST FAN � VAV FAN BOX AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC. � '��������p ��0� <br /> o EG EXHAUST GRILLE l-1 4. ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED <br /> ESP EXTERNAL STATIC PRESSURE WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION -AIR CON�ITIONING -HEAT PUMPS - REFRIGERATION - <br /> 4�� EXN EXHAUST � CEILING EXHAUST FAN INSTRUCTIONS PER I.M.G 2015, SECTION 403, CHAPTER 6, coNrRacroR�s ucer�se ruuMeeR: uNiveai issRF <br /> \ �3" FCU FAN COIL UNIT <br /> y AND SHALL OPERATE, PER W.S.E.C. 2015, SECTION C4O3.3.�. AUBURN: (253)939-5501 TACOMA: (253)922-3141 <br /> FD FIRE DAMPER, FLOOR DRAIN SEATTLE: (253)839-2Y26 FAX: (Z53)735-3432 <br /> O O FpM FEET PER MINUTE O GAS METER 5. EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE <br /> P.O. BOX 614-AUBURN,WASHINGTON 98071 <br /> 1� 409.4 MP REGULATOR VALVES fSD FIRE AND SMOKE DAMPER Z�12 FOR INSPECTIONS. Qc UNIVERSAL REPRIGERATION DRAWING-2D01 <br /> RTU A LISTED SHUTOFF VALVE SHALL BE INSTALLED IMMEDIATELY AHEAD OF EACH MP REGULATOR GA GAUGE 6. ALL HVAC EQMT. TO BE LABELED TO THE SPACE SERVED. <br /> NEOPRENE GASKET GF GAS FURNACE WT DAMPER <br /> �2 409.5 APPLIANCE SHUTOFF VALVE GRD GRILLE, REGISTER, DIFFUSER 7. DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE z <br /> EACH APPUANCE SHALL BE PROVIDED WITH A SHUTOFF VALVE IN ACCORDANCE WITH SECTION 409.5.1, 409.5.0, OR 409.5.3 HP HORSEPOWER, HEAT PUMP VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. Q <br /> WOOD NAILER ID INSIDE DIMENSION ` WITH STRAP, OR 8'-0" MAX. F TRAPEZE SUPPORT. a <br /> �3 VENT LIMITERS ARE DESIGNED FOR USE INDOORS AND IN SPACES WHERE LIMITING THE AMOUNT OF GAS ESCAPEMENT DUE TO DIAPHRAGM FAILURE IS CRITICAL. � -�T THERMOSTAT <br /> VENT LIMITERS ARE NOT TO BE USED OUTDOORS IF THEY ARE EXPOSED TO THE ENVIRONMENT. 13A15 VENT PROTECTOR IS AVAILABLE FOR OUTDOOR USE WHEN IHP INDOOR (SECTION) HEAT PUMP S. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT � <br /> - SECURE BRACKET TO CURB VENT PROTECTION IS REQUIRED. IRH INFRARED HEATER � SETBACK WITH 5 DEGREE DEADBAND. U <br /> WITH (4) #10 SCREWS �4 411.1.6 UNIONS KW KILOWATT � T-BAR SUPPLY DIFFUSER g, THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL W <br /> MBH THOUSAND BTU PER HOUR SECTIONS OF C408 WSEC HAVE BEEN SATISFIED. THIS W <br /> A UNION FITTING SHALL BE PROVfDED FOR APPLIANCES CONNECTED BY RIGID METALLIC PIPE. SUCH UNIONS SHALL BE ACCESSIBLE AND LOCATED WITHIN � <br /> 6 FEET (1829 MM OF THE APPLIANCE. MCD MOTORIZED CONTROL DAMPER � <br /> ) SHALL INCLUDE AS-BUILT DRAWINGS SUBMITTALS 0&M Z � <br /> 18 GA. RESTRAINT BRACKET NC NOISE CRITERIA MANUALS, SYSTEM BALANCE REPORT, AN� A COMMIS- � � <br /> 5� 410.1 PRESSURE REGULATORS NIC NOT IN CONTRACT � T-BAR RETURN GRILLE � � <br /> FACTORY CURB A LINE PRESSURE REGULATOR SHALL BE INSTALLED WHERE THE APPLIANCE IS DESIGNED TO OPERATE AT A LOWER PRESSURE THAN THE SUPPLY PRESSURE. SIONING REPORT. <br /> NT5 NOT TO SCALE � <br /> LINE PRESSURE GAS REGULATORS SHALL BE LISTED AS COMPLYING WITH ANSIZ21.80. ACCESS SHALL BE PROVIDED TO PRESSURE REGULATORS. PRESSURE � [C <br /> NOTES: OBD OPP05ED BLADE DAMPER 10. DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC W <br /> 1. ATfACH BRACKET TO INSIDE TOP OF CURB USING TEK SCREWS SUPPLIED AS SHOWN, REGULATORS SHALL BE PROTECTED FROM PHYSICAL DAMAGE. REGULATORS INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE APPROVED FOR OC ON CENTER � HARDLID SUPPLY DIFFUSER C403.2.8. DUCT WORK WHICH IS DESIGNATED TO OPERATE � � <br /> ATTACH MOUNTING BRACKET TO CURB BEFORE MOUNTING BEFORE MOUNTING UNIT ON CURB. OUDOOR INSTALLATION. OD OUTSIDE DfMENSION OR DIAMETER AT PRESSURES ABOVE 1/2"WATER COLUMN STATIC <br /> 2. AFTER SETTING UNIT ON CURB, ATTACH BOTTOM OF BRACKET TO BASE RAIL ON UNIT WITH � A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTALLED BETWEEN THE MP REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE OHP OUTDOOR HEAT PUMP � PRESSURE SHALL BE SEALED AS FOLLOWS: � <br /> FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE-MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. OSA OUTSIDE AIR HARDLID RETURN GRILLE W r. <br /> TEK SCREWS SUPPLIED AS SHOWN. 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL Q � <br /> 3. A QUANTITY OF FOUR (4) SEISMIC BRACKETS PER ROOFfOP PACKAGE UNIT. �7 A TEE FITTING WITH ONE OPENING CAPPED OR PLUGGED SHALL BE INSTAILED NOT LESS THAN 10 PIPE DIAMETERS DOWNSTREAM OF THE MP REGULATOR OUTLET. OSCI OWNER SUPPLIED CONTRACTOR INSTALLED TRANSVERSE JOINTS AND IONGITUDINAL SEAMS. *- <br /> SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW THE CONNECTION OF A PRESSURE-MEASURING INSTRUMENT. POC POINT OF CONNECTION Fp �— FIRE DAMPER SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT � � <br /> 4. ONE SEISMIC BRACKET IS TO BE INSTALLED ON EACH CORNER OF THE RPM REVOLUTIONS PER MINUTE WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER <br /> ROOFTOP PACKAGE UNIT. <br /> RA RETURN AIR SEAMS SHALL BE SEALED. �I <br /> RAG RETURN AIR GRILLE FSD �— FIRE SMOKE DAMPER W <br /> RTU ROOFfOP UNIT 2. STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL � r <br /> VOLUME DAMPER TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT <br /> SA SUPPLY AIR � WALL PENETRATIONS. <br /> SG SUPPLY GRILLE 11. WSEC FORMS, DUCTING PLANS, BALANCING FEATURES, AS <br /> SP STATIC PRESSURE SD �— SMOKE DETECTOR WELL AS VENTILATION REQUIREMENTS (AS PER TABLE � O <br /> SSG SIDEWALL SUPPLY GRILLE 403.3.1.1, 2015 IMC MINIMUM VENTILATION RATES) AND <br /> TBD TO BE DETERMINED FLEXIBLE DUCT SA/RA OCCUPANCY, ALONG WITH A MECHANICAL PERMIT AT THE � � <br /> TG TRANSFER GRILLE <br /> TYP TYPICAL TIME OF THE TENANT IMPROVEMENT PERMIT. � <br /> UH UNIT HEATER � ROUND DUCT UP . <br /> VFD VARIABLEFREQUENCYDRIVE SCOPE OF WORK � � <br /> VTR VENT TO ROOF , � <br /> WT VARIABLE VOLUME AND TEMPERATURE % ROUND DUCT DOWN JOB# 17129 �+ / "' <br /> 10x10 CD DIFFUSER TAG 1. CHANGEOUT AND REPLACE (1) 3 TON PACKAGE GAS � <br /> 300CFM-10'0 ROOFfOP UNIT WITH SAME LIKE AND KIND. � W <br /> � <br /> � W <br /> J w <br /> . • f_ � r <br /> � �• � � <br /> �'/�i � � T <br /> U W <br /> ��/� � � y� 0 C� � <br /> � � � <br /> � z � <br /> � <br /> � z <br /> 0 <br /> �� � '� '�'�'�' ` � W <br /> �� ��� � '``� <br /> 1, <br /> . 4�'� t '! � � <br /> .I�}i� 1 9 2017 t?_!j � <br /> ,_�- Q <br /> rs- �: o = <br /> £'1"CY r�F F's�'��c:, ,. . <br /> � <br /> � O <br /> � <br /> �. r`f (i� �V�f�E ! ? � <br /> ' �", "s�',a)R �t={-�L�,.,. <br /> PRINT/PLOT DATE: <br /> 6/1 3/1 7 <br /> Pe���crz: nnva6oas DRAFTEFi: <br /> PACKAGE ROOF—TOP UNIT EQUIPMENT SCHEDULE ��teadd�ess: 66°SHAR°�NR° ARW <br /> Owner. PR HOGLAN�LLC <br /> GAS HEATING Terant: ttoe�.o,ruorruNSFeR DESIGNER: <br /> SMOKE NET COOLING EFFICIENCY MOTORIZED app. Cate: 5/�a/2o17 <br /> MINIMUM SOUND SS <br /> ID BRAND NAME MODEL NUMBER AREA OF SERVICE CfM S.P. INPUT OUTPUT CAPACIN OR RELIEF V/PH MCA MOCP WEIGHT Prcposed use: cotitnnERqn� <br /> DETECTOR (Btuh) (Btuh) (Btuh) SEER EER IEER COP OSACFM* AIRDAMPER RATING res�-�p�;o�_ REMovE& aer��i�sraN�asRooFroP PROJECTMANAGER: <br /> RTU-1 CARRIER 48KCDA04A2A6 OFFICE 1,200 NO .5 72,000 59,000 36,410 14.0 - - 82% - - 460/3/6� 11 15 76 SONES 500 LBS urmT-Hoc�alloraarusFER SS <br /> � �� t�ll�ll� JOB NUMBER: <br /> * UNIT INCLUDES FACTORY ECONOMIZER CAPABLE OF 100% OSA Reviewed ey: h� ` '"" oate: / 1%�=.-'- 17y 29 <br /> **HVAC SYSTEM DESIGNED AND ECONOMIZER CONTROLS SHALL �office set _�oe site et _Fire(P�annin�sec <br /> BE SUCH THAT ECONOMIZER OPERATIONS DOES NOT INCREASE SHEET NUMBER: <br /> THE BUILDING HEATING ENERGY USE DURING NORMAL OPERATION n q ^ <br /> (WSEC 2012-C403.4.1.4) I v ' ` ` <br /> � NOTE: These plans are diagrammatical only. P � N � I N G C I TY A P P R O V A L v <br /> Please verify all dimensions at job site. <br />
The URL can be used to link to this page
Your browser does not support the video tag.