Laserfiche WebLink
Carport Arrays General Notes: ,,* ,, <br /> Units 1,2,3 Units 4,5,6 4 ."" L{' , <br /> Units 7,8,9 Units 10,11,12, <br /> (9)Strings of (4)Strings of Utility: Snohomish PUD z "'x.. 11 <br /> Modules (15) Modules and (16)Modules and (8)Strings (9)Strings of * O t �\ t <br /> 72 Optimizers <br /> (4)Strings of g 1. EGC Where exposed to physical damage will be #6AWG Bare CU <br /> D• ( ) (16)Modules; (16)Modules; �`-� - <br /> Total (15) Modules; *2. If installingconduit on the roof, maintaingreater than 7/8" above the surface <br /> (64)Optimizers (64) Totalmizers (7Z)Optimizers <br /> 1Ze� 3211 Martin Luther King Jr Way S. <br /> Total *3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC Disconnect Seattle,WA 98144(206)707-9937 <br /> o•tlmizers Q Equipment Schedule <br /> © +/- I +/- I <br /> +1- +1- Ref. Category Equipment QTY <br /> /� /� 1 Modules Itek 365 SE 531 <br /> \-D /A\-D 2 Optimizers P730 272 <br /> (TYP) (TYP) <br /> 3 Jbox j-box 10 <br /> 3 DC Disconnect Pass-Through Disconnect units F4SK32-1-4XP 5 THIS DRAWING CONSTITUTES THE <br /> g CONFFIDENTIAL INFORMATION OF A&R SOLAR <br /> 3 box AND ITS RECEPTOR POSSESSION DOES NOT <br /> DC DC 4,5,6,7 Inverters Solaredge 43.2K 4 CONFER ANY RIGHT IN OR LICENSE TO USE IT <br /> Roof Top j-box Roof Top j-box Disconnects DisconnectsOR THE INFORMATTION DISCLOSED HERE IN <br /> © 8 CombinerPanel 600A Combiner Panel 1 NOR ANY RIGHT TO REPRODUCE THIS <br /> DRAWING OR ANY PART HERE IN WITHOUT <br /> I I I 1 1 1 THE WRITTEN CONSENT OF A&R SOLAR. <br /> 1 1 I 1 i I 9 MeterBase MeterBase-200A 13Jaw, Comm. Meter Socket, NEMA 3R 1 <br /> () /� �� ) I /� 9 MeterBase CT Enclosure for Production Meter, NEMA 3R 1 N <br /> AWL) <br /> \ I I `7 / \ C� I I /`-\ 10 Disconnect 600A 240V 3 Pole I General Duty, No Fuse 1 <br /> 1 1 1 I i I Monitoring Solaredge PV Monitoring 1 = <br /> 1 1 1 I I 1 <br /> II I I I I Inverter 0 <br /> Inverter Specs Watts (w) AC Voltage #of Inverters OCPD <br /> Inverters, +/- +/- / +/- / +/- / Output(A) 03 <br /> .1 <br /> oirott l SE 43 2K(1) 1 SE 43.2K(2) ( E::SE 43:21 (3) 1 SE 43.2K(4),I • Solaredge 43.2K 43200 120.00 208 4 150 <br /> Location: Level 1 Parking Garage Module Specs Watts (w) Imp Vmp Voc Isc (n ,--I <br /> ( I ) _ � Itek 365 SE 365 9.3 39.12 48.08 9.7 U c co >.0 <br /> (TYP) i `' '- I �1 I > I Temp.Adjusted 35.3 52.5 0 rap ca oN0 <br /> cii <br /> ' l j 0 - cam/) (V) < <br /> PNL PV1 (Combiner Panel) !____ � � Cl � � o � � <br /> D Sola50OCPD S >A W TI Q N m "- <br /> Location: Level 1 Parking Garage <br /> 2:3P150A C l0 '-I ta; <br /> 0. 06 ro M <br /> �\ 3:3P150A 0 O M <br /> C-T Production Meter /E ( I) 4:3P150A CA NJ <br /> C-T Enclosure I 1-i M <br /> /� D Parallel W <br /> I (2)sets of <br /> Location: Room P103 Co-located with conductors & 10 I \'/ \' ,-, U <br /> Fused Disconnect Conduit <br /> Line t O M 1 �W <br /> - � `� House/Commercial MDP 0 <br /> AC Disconnect <br /> I Location: Main Electrical Room L <br /> -- •---- - �• 208/120, 3PH, 4W a <br /> 10 D Parallel (x2) Main Breaker: 2500A <br /> Location: Room P103 Co-located with 1 1 Bus Rating:3000A <br /> C-T Production Meter To MDP Solar OCPD: 3P600A REVISIONS <br /> Ground Bus 1._ PV PV Dist Main Rev. #: Date: <br /> Load 1 4 Dec 27,2018 <br /> A Conductor Schedule - Voltage drop: 1.03% <br /> (QTY) Derated Parallel <br /> Distance Wire Neutral Neutral EGC Conduit Min. Base Temp Fill 75deg Current Operating Voltage <br /> Ref Conductor Description AL/CU Phase Wire Type Ampacit Conduct <br /> (ft) Guage Conductors (AWG) (QTY) (AWG) Type Conduit Amp. Correct. Derate y rating (125%) Voltage Drop ors <br /> A Roof to Jbox 140 CU #10 2 N/A N/A #6 PV Wire 600V N/A N/A 40 0.96 100% 38.4 30 18.8 400 1.27% No Designed by: Daniel H. <br /> B Jbox to Inverter 65 CU #10 8-10 N/A N/A #10 THHN,THWN-2 EMT 1" 40 0.96 50% 19.2 30 18.8 400 0.59% No PM: Andrew Houle <br /> 331-0485(262) <br /> C DC Disco to Inverter 65 CU #10 8-10 N/A N/A #10 THHN,THWN-2 PVC 1" 40 0.96 50% 19.2 30 18.8 400 0.59% No Current Date:Dec 27, 2018 <br /> D Inverter to Combiner 10 CU 1/0 3 #6 1 #6 THHN,THWN-2 EMT 1.5" 170 0.96 100% 163.2 150 150.0 208 0.12% No PV-E1 Singl <br /> E Combiner to Disconnect 10 AL 500 3 #1 1 #1 THHN,THWN-2 EMT 3" 700 0.96 100% 672.0 620 600.0 208 0.8.% Yes <br /> F Disco.to interconnection 10 AL 500 3 #1 1 #1 THHN,THWN-2 EMT 3" 700 0.96 100% 672.0 620 600.0 208 0.8.% Yes Line <br />