Laserfiche WebLink
PV Electrical Calculations <br /> Watts Output AC #of Comb.AC Comb. EGC <br /> Inverter Specs <br /> (w) (A) Voltage Inverters OCPD out.(A) OCPD (AC) Array Specs (Adjusted for Temperature) <br /> 3211 Martin Luther King Jr Way S. <br /> Seattle,WA 98144(206)707-9937 <br /> SolarEdge SE43.2KUS 43200 120.00 208 1 150 Inverter SolarEdge SE43.2KUS SolarEdge SE43.2KUS <br /> SolarEdge SE43.2KUS 43200 120.00 208 2 150 480.0 600 #1 Mppt Input 1 2 3 1 2 3 <br /> SolarEdge SE43.2KUS 43200 120.00 208 1 150 Amperage(Imp) 43.80 41.6. 41.6. 43.80 43.80 27.37 <br /> EGC <br /> Module Specs Watts Imp Vmp Voc Isc Temp. Coef V(oc)(w (DC) <br /> Voltage(Vmp) 400.0 400.0 400.0 400.0 400.0 400.0HIS CONFFIDENTIAL <br /> ININFORMATION <br /> OP RE <br /> CONFTIINFORMATION OF A&R SOLAR <br /> AND ITS RECEPTOR POSSESSION DOES NOT <br /> CONFER ANY RIGHT IN OR LICENSE TO USE IT <br /> Itek 365 SE 365 9.3 39.12 48.08 9.7 -0.29 #10 Max Voltage(DC) 600.0 600.0 600.0 600.0 600.0 600.0 oRTHE INFORIGHT TNDISCLOSED REPRODUCE THIS <br /> NOR ANY RIGHT TO REPRODUCE THIS <br /> DRAWING OR ANY PART HERE IN WITHOUT <br /> THE WRITTEN CONSENT OF A&R SOLAR. <br /> Temp. Adjusted 35.3 52.5 Max Amps (DC) 45.0 45.0 45.0 45.0 45.0 30.0 <br /> Optimizer? P730 Max current output: 15A, Max Voltage:600V Max Array Power(STC): 193.815 kW DC N <br /> C <br /> Equipment0 <br /> SolarEdge SE43.2KUS SolarEdge SE43.2KUS SolarEdge SE43.2KUS Max Continuous AC Power: 172.8kW AC <br /> 113 <br /> Mppt Input 1 2 3 1 2 3 1 2 3 <br /> Module Itek 365 SE Itek 365 SE Itek 365 SE UU c o > o <br /> Fl r - N <br /> # Modules per String 16 15 15 16 16 15 15 16 16 Interconnection Calcs Site Conditions L Em m <br /> 0 VI 00 <br /> # Parallel Strings 3 3 3 3 3 2 3 3 3 Main Breaker 200 ASHRAE Site: Seattle L 2 nOL <br /> m <br /> #of Modser Mppt p pp 48 45 45 48 48 30 45 48 48 Bus Bar 200 Low Temp(°F) 19 ,H <br /> #of Mods/inverter a m >-no --- M cu <br /> 126 141 Max PV OCD Allowed 40 High Temp(°F) 84 0 NI Cr) cu <br /> iJ <br /> #of Inverters <br /> 1 2 1 PV OCPD Device Used 600 High 2%Temp(°F) 91 •• <br /> LLJ <br /> Total # of Modules 531 <br /> Tap or Breaker? Tap U <br /> CO <br /> ■^ <br /> 0 <br /> L <br /> Distance (QTY)Phase Neutral Neutral EGC Conduit Min. Base Temp Fill Derated 75deg Current Operating Voltage Parallel d <br /> Conductor Description AL/CU Wire Guage Wire Type <br /> (ft) Conductors (AWG) (QTY) (AWG) Type Conduit Amp. Correct. Derate Ampacity rating (125%) Voltage Drop Conductors <br /> Ref. <br /> A Roof to Jbox 140 CU #10 2 N/A N/A #10 PV Wire 600V EMT N/A 40 0.96 100% 38.4 30 18.8 400 1.27% No REVISIONS <br /> Rev. #: Date: <br /> 1 Nov 21, 2018 <br /> B Jbox to Inverter 65 CU #10 840 N/A N/A #10 THHN,THWN-2 EMT 1" 40 0.96 50% 19.2 30 18.8 400 0.59% No <br /> C DC Disco to Inverter 65 CU #10 8-10 N/A N/A #10 THHN,THWN-2 PVC 1" 40 0.96 50% 19.2 30 18.8 400 0.59% No <br /> D Inverter to Combiner 10 AL 3/0 3 #6 1 #6 THHN,THWN-2 EMT 2" 175 0.96 100% 168.0 155 150.0 208 0.13% No <br /> E Combiner to Disconnect 10 AL 500 3 #1 1 #1 THHN,THWN 2 EMT 3" 700 0.96 100% 672.0 620 600.0 208 0.8.% Yes Designed by: Daniel H. <br /> - PM: Andrew Houle <br /> F Disco. to interconnection 10 AL 500 3 #1 1 #1 THHN,THWN-2 EMT 3" 700 0.96 100% 672.0 620 600.0 208 0.8.% Yes (262) 331-0485 <br /> Current Date:Nov 21, 2018 <br /> G PV-E2 Electrical <br /> Calculations <br /> Total Voltage Drop: <br /> 2.75% <br />