Laserfiche WebLink
:;�- <br /> ;':�-- <br /> H V A C (MOTOR, COMPRESSOR, HEATER SIZES) <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. <br /> COMPRESSOR 14.7 RLA 112 LRA <br /> ;��. <br /> INDOOR BLOWER FAN 2.2 FLA 1/3 HP x <br /> � � OUTDOOR BLOWER FAN 1.5 FLA 1�5 HP <br /> HEAT STRIP 10 KVA 240 VOLT <br /> MINIMUM CIRCUIT AMPS $'I AMPS � <br /> � (2� 8' x 4' WHITE BOARDS w� N MAXIMUM OVERCURRENT PROTECTION 9O AMPS <br /> � <br /> MARKER TRAY (SHIP LOOSE� ELECTRIC OVERCURRENT PROTECTION SHALL BE DUAL ELEMENT <br /> INSTALLED ON SITE BY OTHERS PANEL TIME DELAY FUSE OR HACR CIRCUIT BREAKER <br /> B B B PANELSCHEDULE <br /> �� NOTE:ALL CONDUCTORS COPPER. 200 AMP 1� 22,000 AIC E. <br /> WP <br /> GFCI CKT TRIP WIRE VOLT ZOO VOLT WIRE TRIP CKT �. � <br /> DESCRIPTION DESCRIPTION • <br /> NO. AMPS SIZE AMPS ��/� B�� AMPS SIZE AMPS NO. <br /> 1 LIGHTS 20 12 792 — — 7208 4 90 HVAC 2 <br /> � 3 RECEPTACLES 20 12 1260 �� �� 7208 / / / 4 <br /> �� <br /> z z 5 RECEPTACLES 20 12 1080 �� �� - -- 20 SPARE 6 ' � <br /> � . <br /> O J � 7 RECEPTACLES 20 12 972 �� �� - - 20 SPARE g <br /> �� 2�4 9 'i-';�:CE �\ /� 20 SPARE 10 <br /> �� .�-:�. , �1 �'\ <br /> C r�w 11 .,-:,�,E _ _.. — — _ .... 20 SPARE 12 <br /> C� Q 13 :;�,,,r,� �� �1 20 SPARE 14 <br /> B B B z� 1 s „�:.,, �'� �� <br /> ,,-n.� — — 20 SPARE 16 <br /> .,.. _ <br /> :.,:�. <br /> --- - --- — - -- - ----- - -------- - -- .-�� __...- - _---- -_ ------ - ------ - ----T- . ,:.,C" _. �� �\ 20 SPARE 18 <br /> -- — -- --- �� <br /> � � 19 �='=;.CE �� �� _ _. 20 SPARE 20 <br /> � � ` " <br /> /� � . <br /> � ELECTRICAL PLAN REVIEW � <br /> � � �� ` LOAD CALCULATIONS <br /> � �� <br /> � � � � �� VOLTAGE: 120/240 PHASE: 1� <br /> DAYLIGHTING � % <br /> T �' A P A P �7 CONNECTED LOAD CALC. LOAD <br /> � � � LIGHTING <br /> ,�,� � <br /> , <br /> / � EXTERIOR 72 VA x 125 % = 90 VA <br /> :., �' INTERIOR 792 VA x 125 % = 990 VA <br /> - - �= �,; . <br /> � — <br /> SECONDARY <br /> - , (� <br /> �__--- . ..__ '__'"_-' - ___ - ' / �.�,. �. <br /> RECEPTACLES <br /> BIA � THRU 10,000 3240 VA x 100 % = 3240 VA <br /> . <br /> OVER 10,000 0 VA x 50 % = 0 VA , <br /> , _ <br /> ; _..............---.__._.._.....__ <br /> MOTORS, COMPR. <br /> PRIMARY TOTAL 4416 VA x 100 % = 4416 VA <br /> LARGEST (3528) VA x 25 % = 882 VA <br /> HEATING 1000o vA x 100 / = 1000o vA <br /> NOTES: E L E C T R I CA L P LA N . <br /> 1. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE TOTAL KVA 18.52 TOTAL KVA 19.62 ;;�:�_ �' <br /> BY A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID 1/4" = 1'-0" ARS 2/1/16 CONNECTED CALCULATED = <br /> CONDUCTORS OR OTHER APPROVED MEANS OF TERMINATION. LOAD AMPS 77,� 7 LOAD AMPS 81 .74 <br /> 2. ALL CONDUCTORS ARE COPPER;TYPE THHN. ' <br /> E L E C T R I C A L S Y M B 0 L S � <br /> 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br /> HEIGHT <br /> SYMBOL DESCRIPTION TO TOP REMARKS <br /> 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. <br /> � SINGLE POLE MOMENTARY SWITCH 48" LOW VOLT OCC SENSOR CONTROL <br /> 5. LIGHTING CONFORMS TO WASHINGTON STATE ENERGY CODE <br /> � DUPLEX RECEPT. 20" 180 VA EACH <br /> 51-1 1 C, CHAPTER 4 SECTION C405. <br /> �FP� WEATHER PROOF/GRD. FAULT 16" 180 VA EACH <br /> b. THIS PLAN IS NOT AN"AS-BUILI"'DRAWING <br /> � QUAD PLEX RECEPT. 20" 360 VA EACH <br /> r::;„ <br /> OS OCCUPANCY SENSOR CEILING LOW VOLT w/ POWER PACK f <br /> QTY. SIZE DESCRIPTION � LIGHT SENSOR CEILING 0-10V DIMMING CONTROL <br /> ONE-LINE-DIAGRAM � PHONE/DATA BOX 20" STUB UP & DOWN w/ 3/4" , <br /> ELECTRICAL PANEL 1 200 AMP 120/240V - SINGLE PHASE - STUB THRU - METALLIC RACEWAY SYSTEM 200 AMP FEEDER PANEL FLEX CONDUIT <br /> MAIN BREAKER � PULL STATION 48" <br /> LIGHTING 3 2 x 4 TROFFER (3) T-8 32 WATT TUBES - 0-10V PROG DIMMING BALLAST 120/240 1� � FIRE ALARM HORN/STROBE (INT) 84" �/2" RACEWAY ONLY <br /> PAINT SUBSTANTIALLY RED <br /> 200 AMP � FIRE ALARM HORN/STROBE (EXT) 84" <br /> 6 2 x 4 TROFFER (3) T-8 32 WATT TUBES - ELECTRONIC BALLAST <br /> O THERMOSTAT 48" TO TOP OF J-BOX <br /> 1 72W LED FIXTURE w/ PHOTO CELL 1/2" PVC 2" PVC STUB � PORCH LIGHT 84" 72 VA EACH . <br /> �, <br /> STUB FOR BY BLAZER .. <br /> H.V.A.C. 1 3 TON 10 kW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER FUTURE (2) 3/0 Cu THHN P� O PROGRESSIVEDIMMING BALLAS CEILING ggT q TEACHEFXTURELLAST <br /> GROUNDING (1) 1/0 Cu THHN � � <br /> THERMOSTAT � HONEYWELL w/ MICROPROCESSOR- 7 DAY PROGRAMMABLE BONDING — �1) #4 Cu 3 T-8 TUBE ELECT. BALLAST <br /> VISIONPRO TH8320U AUTOMATIC SETBACK- DEADBAND CONTRo� (WIRE ON SITE BY OTHERS) � 24" x 48" TROFFER CEILING gg VA EACH FIXTURE . <br /> g POWER PANEL 72" <br /> 2-1-16 ELECTRICAL ENGINEERING REVIEW ARS COPYRIGHT2016, BLAZER INDUSTRIES, INC. � MODULAR Classroom for.• ApprovedforConst: JOb NO. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED � 28 X 32 KC DA - Eve rett S■D■ <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� INDUSTRIES,�Nc. <br /> i� www.blazerind.com Drawn By: JWfZ � <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. ■� P.O.BOX489 ■ Aumsville,OR97325-0489 W/4. GOLD Pacific Mobile 14 BLMP-11 A3 Everett, �/A Issue�ate: 02/01/16 ' <br /> ,;:�G <br />