My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8702 7TH AVE SE 2018 Plans 2022-12-05
>
Address Records
>
7TH AVE SE
>
8702
>
Plans
>
8702 7TH AVE SE 2018 Plans 2022-12-05
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2022 10:29:22 AM
Creation date
9/5/2019 9:50:19 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8702
Permit
B1803-027
Year
2018
Notes
ADD 1 PORTABLE CLASSROOM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- �:.. <br /> ;::y.. <br /> �:..¢. <br /> BERC2 CLIP , <br /> POP RIVET <br /> 2 x 2 SUPPLY 2 x 4 FLUORESCENT £ <br /> AIR DIFFUSER TROFFER <br /> n <br /> �n CROSS TEE CROSS TEE <br /> #8 x 1/2" ROUND WASHER , <br /> HEAD TEK SCREW WALL ANGLE <br /> (SELF— TAPPING) <br /> NOTE: SCREW IS NOT — — — — — . <br /> WALL ANGLE TIGHTENED DOWN AGAINST • <br /> BERC2 CLIP � <br /> UNATTACHED WALL ATTACHED WALL <br /> (TWO ADJACENT WALLS) (TWO ADJACENT WALLS) A <br /> SEISMIC BERC2 CLIP <br /> —FACTORY INSTALLED AT TWO AUJACENT WALLS. <br /> —SCREW TIGHTENED FOR SHIPPING IN ROOMS WHERE i �� <br /> CEILING CROSSES MOD I INE, LOOSEN SCREW ON SITE �_, _ <br /> BY SET UP CREW � <br /> SUSPENDED CEILING GRID BERC2 CLIPS M—� <br /> SEISMIC ATTACHMENT AT WALLS REFLECTED CEILING PLAN <br /> 3" = 1'-0" [ARMSTRONG SEISMIC 'Rx' SUSPENSION <br /> SYSTEM (ESR 1308)] 1/8" = 1'-0" <br /> �;E.: <br /> MECHANICAL NOTES: '���� <br /> ::>:: <br /> 1. DUCT MATERIAL IS 26 GA. GALV. AND FLEX DUCT. DUCTWORK SHALL BE SUPPURTED PER IMC <br /> CHAPTER 6. SECTION 603 <br /> 2. MATERIAL IN DUCTS SHALL HAVE A FLAME SPREAD INDEX OF LESS THAN 25, SMOKE DEVELOPMENT <br /> OF 50 PER IMC CHAPTER 6. SECTION 602 <br /> SUPPLY AIR <br /> 3. LOW PRESSURE DUCT SYSTEMS SHALL HAVE LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND PLENUM #PWS015 <br /> CONNECTIONS OF SUPPLY AND RETURN DUCTS AND PLENUMS SECURELY FASTENED AND SEALED WITH <br /> WELDS, GASKETS, MASTICS (ADHESIVES), MASTIC—PLUS EMBEDDED—FABRIC SYSTEMS OR APPROVED TAPES �2�'0�'0 <br /> INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS 1 12 <br /> 10 0 12 <br /> 1 ;a�; <br /> 4. WHEN ISOLATION SLEEVES ARE USED AT LINE CONNECTIONS TO PLENUMS, THEN THEY SHALL COMPLY _ _ _ _ _ _ _ _�ti'1o' '�:, <br /> ' __ T''__'"___-- <br /> WITH IMC CHAPTER 6 3 TON 10 kw �`5L <br /> HEAT PUMP ' <br /> 5. 10" DIFFUSERS WITH NO MANUAL DAMPERS. USE FLOW CONTROLS AT WYES, TYPICAL AS NOTED ON PLAN w/ ECONOMIZER <br /> 1100 cfm MAX <br /> � 6. MINIMUM 390 CFM OUTSIDE AIR REQUIRED PER IMC CHAPTER 4 s� <br /> 7. OUTSIDE AIR DAMPERS SHALL COMPLY WITH WSEC <br /> 8. SINGLE PACKAGE UNITARY FAN COOLING UNITS HAVING A TOTAL COOLING CAPACITY OF GREATER THAN <br /> 20,000 Btu/h REQUIRE ECONOMIZERS PER WSEC <br /> 9. THE BUILT—IN ECONOMIZEP. SYSTEM IS INTERNALLY MOUNTED BEHIND THE SERVICE DOOR AND ALLOWS <br /> UP TO 100� OUTSIDE AIR THRU THE AIR INLET OPENINGS. IT INCLUDES A BUILT—IN EXHAUST AIR <br /> DAMPER. THE ECONOMIZER IS DESIGNED TO PROVIDE "FREE COOLING" WHEN THE OUTSIDE AIR M E C HAN I CAL P LAN `� <br /> TEMPERATURE IS COOL ENOUGH TO PROVIDE NEEDED COOLING WITHOUT USING THE COMPRESSOR. ��'4 <br /> THIS IN TURN PROVIDES LOWER OPERATING COSTS, WHILE EXTENDING THE LIFE OF THE COMPRESSOR ' <br /> 1/8„ = 1'—�» <br /> QTY. SIZE DESCRIPTION <br /> H.V.A.C. 1 3 TON 10 kW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER <br /> INDOOR THERMOSTAT � HONEYWELL w/ MICROPROCESSOR— 7 DAY PROGRAMMABLE <br /> VISIONPRO #TH8320U AUTOMATIC SETBACK— DEADBAND CONTROL <br /> OUTDOOR THERMOSTAT � CMH-14A <br /> COPYRIGHT2016, BLAZER INDUSTRIES, INC. � MODULAR Classroom for. ApprovedforConst: JOb No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY - <br /> OF BLAZER INDUSTRIES, INC.AND SHALL �� 28 X 32 KC DA - Eve rett S■D■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED � � <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE �� INDUSTRIES,INC. Drawn By: JWR � <br /> �� www.blazerind.com �/A. GOLD Pacific Mobile 14 BLMP-11 A3 Everett WA <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. �� P.O.BOX 489 ■ Aumsviiie,OR 97325-0489 � Issue Date: O2/01/16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.