3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-23
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-23 Plans 2022-12-06 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:46:08 PM
Creation date
9/12/2019 2:11:50 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-23
Permit
B1809-027
Year
2018
Notes
INSLATT NEW COMPRESSORON GROUND FLOOR DRYER PADS MEZZANINE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SUBSTATIONS 11-1 AND 11-2 SECTION 26 11 16 <br /> PROJECT#22349762 SECONDARY UNIT SUBSTATIONS <br /> BOEING- EVERETT SITE SERVICES <br /> mechanical trip button located on the front of the breaker. Mechanical trip shall be <br /> accessible without opening the compartment door. <br /> 11. Electrically operated breakers shall utilize a motor automatically charge the closing <br /> springs. Breakers control shall be provided on the face of the breaker cells. Tripping <br /> shall be via shunt trip coil. Closing shall be via spring release coil. Provide red and <br /> green LED type lights for each breaker for open/close indication. <br /> 12. All circuit breakers shall be 3 pole devices with visual indication of CONNECT, TEST <br /> and DISCONNECTED positions. <br /> a. All breakers shall have GE MDP relays with a combination of long time, short <br /> time, and instantaneous tripping characteristics, and ground fault protection. <br /> b. Tie breaker shall have the same characteristics as the main breaker and shall be <br /> interchangeable. <br /> c. Power will be provided from a CPT for electrically operated breakers at 120VAC <br /> for trip, charge and close. Each control power transformer shall be suitably sized <br /> to accommodate total switchgear auxiliary loads. <br /> d. All breakers shall be equipped with capacitor trip unit, model CTD-2. <br /> 13. Mechanical rejection devices are to be installed to inhibit installation of breakers of <br /> different frame ratings. <br /> 14. Provide cleats mounted on the structure for cable supports,for each feeder. <br /> 15. Provide a continuous copper ground bus through the medium voltage switchgear with <br /> bronze ground lugs at each end of the substation lineup for connection to a 250Kcmil <br /> AWG bare copper grounding conductor, and for each feeder. Ground each arrester, <br /> transformer core, case, etc., separately to the ground bus. <br /> 16. Provide engraved black on white phenolic nameplates on all compartments. Mount <br /> nameplates with screws. Nameplates shall identify feeder designation, trip rating and <br /> cell designation. <br /> 17. Breaker compartments identified as PROV. Shall be equipped for future installation of <br /> the feeder breaker, including racking rails and bussing. Provide with secondary <br /> disconnecting contacts,control switch, indicating lights, CT's and MDP relay. <br /> 18. Provide automatically operating insulated shutters to cover line and load connections <br /> in all main, tie,feeder, and space cells. <br /> 19. Tie breaker Compartment. <br /> a. Provide a separate vertical section compartment to house only the tie breaker <br /> and associated busing. <br /> b. Provide a full metal barrier between the front breaker cell and the main bus <br /> connections. <br /> B. Control Power Transformer: Provide suitably sized 120VAC secondary control power <br /> transformers to provide control power to the medium voltage secondary switchgear and <br /> the transformer fans. Primary and secondary fusing shall be provided. Locate in <br /> accessible cubicle of switchgear to allow maintenance without shutting down 2400V <br /> power to medium voltage switchgear. <br /> C. Control Wiring: Stranded copper, SIS type. Enclose control wiring size No. 14 AWG, <br /> Type SIS in top and vertical metal wiring troughs and front-to-rear metal wiring troughs; <br /> furnish necessary fuse blocks and terminal blocks within the switchgear when required. <br /> Provide the terminal blocks in a metal enclosed wiring trough for all groups of control <br /> wires for interconnection within or leaving the switchgear mounted in the rear cable <br /> compartment, easily accessible, away from the runbacks and cable terminals, and with a <br /> bolted steel cover over the terminal blocks. Bus taps only shall be No. 8 AWG SIS wire. <br /> D. Provide terminal blocks for interconnection of control wiring across shipping splits by <br /> terminal blocks in the control wiring trough on top of the equipment. All terminations shall <br /> 26 11 16- 11 <br /> (07/15/18) <br />