9 r' <br /> Nov. 20 t" 2014 <br /> ARCHITECTURAL DESIGN <br /> ASSOCIATES, PS <br /> a) Detail 4 on sheet A4.1 showing the 1-hr required assembly has been add to the set and <br /> referenced from the Elevations & building section. <br /> 3.The two, one-hour walls separating the dwelling units requires mineral fiber per GA No. <br /> 3644. Wall section 3/A4.2 should be revised to show this requirement or a different fire- <br /> resistive wall assembly should be provided. Section R303.2 <br /> a) Have changed the (2) one-hour walls to one 2-hr party wall assembly. Wall section <br /> 3/A4.2 has been updated to reflect this as well as detail 3b/A4.2. <br /> 4.Wall section 3/A4.2 should be clarified to show that fire-retardant sheathing is also required <br /> for eave overhangs and over-framing within 4' of the two-hour wall. Section R302.2.2 <br /> a) The wall section 3/A4.2 has been clarified with a notation for 1-Hr fire-retardant <br /> sheathing for eaves and over-hanges w/i 4' of party wall. <br /> 5.The site plan shows approximately 10 feet between buildings B and C. Based on that <br /> distance, the eves parallel to the assumed property line should be protected on the <br /> underside by one-hour, fire-resistive construction. Section R302.1 <br /> a) A notation has been added to the building elevation sheet (A1.1) and roof plan sheet <br /> (A2.4) for min. 1-Hr fire protection to underside of eves that are less than 5' from the <br /> assumed property line. <br /> 6.The two-hour walls should be shown to continue to the underside of the over-framed dormer <br /> sheathing between units 2 &3. Section R302.2 <br /> a) Elevation sheets A1.1 show & notate the 2-hr wall to continue to the underside of the <br /> over-framed sheathing <br /> 7.An additional 20-minute door (or approved alternate) should be added to create a hallway <br /> between the 'storage' rooms and garages on the lower floors. The doors into the storage <br /> rooms could then be reduced to a non-rated passage doorway and note stating 'rooms not <br /> to be used as sleeping rooms' should be removed from the plans. Section R302.5.1 <br /> -The CO alarms should be shown in the (new) hallway outside of the sleeping <br /> rooms on the first level. Section R315.1 <br /> -An additional smoke alarm should be shown in the (new) hallway outside of the <br /> sleeping rooms on the first level. Section R314.3 <br /> a) Floor plan A2.2 has been revised to reflect the change showing a "new" hallway off of <br /> the garage and a second 20 min. door into the conditioned space to the rear of the <br /> garage in the 16' wide units <br /> -CO alarm has been shown in the "new" hallway out side of the sleeping rooms <br /> -Additional smoke detector is shown in the "new" hallway out side of the <br /> sleeping rooms <br /> 8.The glazing at the stair landing in Unit 4 should be shown to be a minimum of 36" a.f.f or <br /> safety glazing. Section R30S.4.7 . (7) <br />