My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1418 106TH PL SE BLDG B 2019-09-12
>
Address Records
>
106TH PL SE
>
1418
>
BLDG B
>
1418 106TH PL SE BLDG B 2019-09-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2019 3:59:24 PM
Creation date
9/12/2019 3:59:21 PM
Metadata
Fields
Template:
Address Document
Street Name
106TH PL SE
Street Number
1418
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
y <br /> Nov. 18t", 2014 <br /> ARCHITECTURAL DESIGN <br /> ASSOCIATES, PS <br /> referenced from the Elevations & building section. <br /> 3.The two, one-hour walls separating the dwelling units requires mineral fiber per GA No. <br /> 3644. Wall section 3/A4.2 should be revised to show this requirement or a different fire- <br /> resistive wall assembly should be provided. Section R303.2 <br /> a) Have changed the (2) one-hour walls to one 2-hr party wall assembly. Wall section <br /> 3/A4.2 has been updated to reflect this as well as detail 3b/A4.2. <br /> 4.The two-hour walls should be shown to continue to the underside of the over-framed dormer <br /> sheathing between units 2 &3. Section R302.2 <br /> a) Elevation sheets A1.1 show & notate the 2-hr wall to continue to the underside of the <br /> over-framed sheathing <br /> 5.An additional 20-minute door (or approved alternate) should be added to create a hallway <br /> between the 'storage' rooms and garages on the lower floors. The doors into the storage <br /> rooms could then be reduced to a non-rated passage doorway and note stating 'rooms not <br /> to be used as sleeping rooms' should be removed from the plans. Section R302.5.1 <br /> -The CO alarms should be shown in the (new) hallway outside of the sleeping <br /> rooms on the first level. Section R315.1 <br /> -An additional smoke alarm should be shown in the (new) hallway outside of the <br /> sleeping rooms on the first level. Section R314.3 <br /> a) Floor plan A2.1 has been revised to reflect the change showing a "new" hallway off of <br /> the garage and a second 20 min. door into the conditioned space to the rear of the <br /> garage in the 16' wide units <br /> -CO alarm has been shown in the "new" hallway out side of the sleeping rooms <br /> -Additional smoke detector is shown in the "new" hallway out side of the <br /> sleeping rooms <br /> 6.The 2'6"x2'6" slider in the master bathroom of unit #1 should be shown as safety glazing. <br /> Section R308.4.5. <br /> a) Window has been called out as Safety glass on plan & window schedule. <br /> 7.Opening windows on the 3 floor front elevation should be shown to be a minimum of 24" <br /> from the finished floor to the actual opening of the window. Section R312.2 <br /> a) Elevation has been revised to reflect this change (Re:1/A1.1) also the addition of notes <br /> on the floor plan & window schedule on sheet A2.3.- <br /> 8.The glazing at the stair landing in Unit 4 should be shown to be a minimum of 36" a.f.f or <br /> safety glazing. Section R30S.4.7 . <br /> a) The window in question is show on the elevations (Re:1./A1.1) to be minimum of 36" A.F.F. <br /> & for further clarification a notation has been add o the window on plan sheet A2.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.