3003 W CASINO RD 2018 BLDG 45-08 Plans 2022-12-06
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-08
>
Plans
>
3003 W CASINO RD 2018 BLDG 45-08 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:58:40 PM
Creation date
9/13/2019 2:41:56 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-08
Permit
M1804-041
Year
2018
Notes
EXPAND WASTE TREATMENT FACILITY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CODE SUMMARY <br /> OWNER: BOEING DATE: SEPTEMBER 2016 G E I� E RA� f� OT E S ` <br /> PROJECT NAME: BOEfNG WASTEWATER TREATMENT PLANT 45-08 PROJECT NO.: 10507612 1. ADJACENT BUILDINGS AND STRUCTURES TO BUILDING 45-08 ARE T <br /> REQUIRED TO BE SEPARATED BY A DISTANCE OF 30 FEET (IBC <br /> PROJECT LOCATION: EVERETT, WASHINGTON 2015 T602). . <br /> 2. BUILDING 45-08 IS EQUIPPEQ WITH AN EXISTING AUTOMATIC FIRE <br /> AREA/BUILDING : 45-08 SPRINKLER SYSTEM. <br /> a 3� NOT CONSIDERED AN EXIT DOOR. <br /> � GOVERNING CQDES <br /> � <br /> ao BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) WITH STATE OF WASHINGTON AND CITY OF EVEREIT AMENDMENTS ACCESIBLITIY CODE: N/A <br /> o ' <br /> N <br /> � FIRE CODE: 2Q15 INTERNATIONAL FIRE CODE (IFC) WITH STATE OF WASHINGTON AND CITY OF EVERETT AMENDMENTS NFPA CODE: 30, 70 & 704 <br /> � <br /> � REFERE�JCE DRAWi �I �S { <br /> � ENERGY CODE: 2015 INTERNATlONAL ENERGY CODE (IEC) WITH WASHINGTON AMENDMENTS AND PUGET SOUNDS ENERGY CODE QTHER: 2009 UPC, IMC & NEC WITH WA AMENDMENTS <br /> w <br /> � SEE DWG. 45-08-1A10, FOR FLOOR PLAN � <br /> NAZARDOUS MATERIA�S ( 1 ) (2) SEE DWG. 45-08—A60, FOR EXTERIOR ELEVATIONS <br /> SEE DWG. 45-08—RFA160, FOR ROOF PLAN <br /> NFPA 704 RATING HAZARD PROPERTIES <br /> CHEMICAL CAS N0. CONCENTRATION QUANTITY REMARKS <br /> � HEALTH FLAMMABILITY REACTIVITY SPECIAL PHYSICAL HEALTH <br /> CAUSTIC SODA 1310-73-2 25� 4,500 GAL 3 0 2 � WR1 COR H-4 OCCUPANCY <br /> COR=500 GAL MAX WR1=N0 LIMIT <br /> � SODIUM BISULFITE 7631-90-5 15-40% 2,000 GAL 2 1 0 — — — — � <br /> � <br /> v <br /> � POLYMER (CHEM TREAT P817E) MIXTURE 15-40% 100 GAL 1 1 0 — — — — <br /> � • <br /> U I � <br /> � DEFOAMER NALCO 71D5 PLUS MIXTURE 30-60% 55 GAL 2 2 0 — — — — <br /> w <br /> cn <br /> � <br /> USE AND OCCUPANCY CLASSIFICATION/ AL�OWAB�E AREA AND HEIGHT (3) (4) <br /> � � OCCUPANCY GROUP CONSTRUCTION ALLOWABLE ACTUAL ALLOWABLE AUTOMATIC ACTUAL AREA/ AREA MODIFICATION ' <br /> TYPE HEIGHT HEIGHT AREA SPRINKLER ACTUAL AREA ALLOWABLE AREA <br /> AND DESCRIPTION (6) RATIO FRONTAGE INGREASE <br /> A BUSINESS GROUP B OCCUPANCY ��B 55 FT 24 Ff 23,000 SF NOT 340 SF .015 N/A <br /> - � E o a ���� (NON— RATED) 3 STORIES 1 STORY REQUIRED <br /> t 1 . <br /> � o <br /> ��,�,��t) c�usnc� ��� I 0 I MODERATE—HAZARD FACTORY IIB 55 FT 24 F-f NOT <br /> ° ��y �y ��T� I INDUSTRIAL GROUP F-1 OCCUPANCY ( ) 15,500 SF 175 SF .011 N/A <br /> � NON— RATED 2 STORIES 1 STORY REQUIRED <br /> 0 <br /> (�-sro) <br /> � � ' 30' FT EXIT TRAVEL 33' FT EXIT HIGH HAZARD GRQUP IIB 55 FT 24 fT 17,500 SF REQUIRED 3,630 SF .207 N/A <br /> �� � DISTANCE TRAVEL DISTANCE �� OFFICE/CONTROL ROOM H-4 OCCUPANCY (NON— RATED) 3 STORIES 1 STORY <br /> I �_ _! � I U I � � � OCCUPANCY <br /> o . <br /> -�� � � ��4 MEANS OF EGRESS (9) <br /> -- 3 , <br /> ----r� MAX FLOOR TOTAL COMMON <br /> g — � i ' — — — —��� R00�1 OR FUNCTION PATH OF EXITS EXITS EXIT ACCESS <br /> - � ''' j�j ll,' !' � I — �_'' AREA NAME OF SPACE AREA PER OCCUPANT TRAVEL REQ D PROVIDED TRAVEL DIST STAIRWAYS ; <br /> � � _-_ ,� � � � � '�► � OCCUPANT LOAD DISTANCE <br /> ♦ `��6� PROCESS AREA �� <br /> H-4 OCCUPANCY I F-1 OCCUPAN � MECHANICAL <br /> PROCESS AREA 11A1 EQUIPMENT 300 12 25 FT 2 3 68 FT N/A <br /> 11A1 °� I 11 B4 <br /> � 47' Ff EXIT TRAVEL � OFFICE/CONTROL ROOM 11A4 BUSINESS AREA 100 3 0 FT 1 1 17 FT N/A <br /> DISTANCE ' <br /> PAllEf RPqC � ... <br /> �o MEDM RTERS — (OYINER PROY�ED) . <br /> � ran�sao _ .� _ _ _ MECHANICRL <br /> ��� C MCC 11 B4 EQUIPMENT 300 1 0 FT 1 1 35 FT N A <br /> w� ACCESS F(R�E— � <br /> � � _ � �� �'"'� �STqiR i CCUPANCY SEPARATION WALL - <br /> � ��� �O� I � ��,�.�� � 7' FT EXIT TRAVEL : <br /> v � � �-=�-_� � � bISTANCE � OCCUPANCY SEPARATION (4): 1 HR REQUIRED BETWEEN F—I/B AND H-4 <br /> tc�eorra�) _ '�– �' _� <br /> � 0 � - <br /> - <br /> . � . ���� , � <br /> � � � g FIRE RESISTANCE RATIf�G OF STRUCTURAL E�EMENTS (5): 0 <br /> � _ - <br /> ' �- MAINTENANCE AREA <br /> i - �DEfQWFR <br /> � - � - ' �°° � � ���� 11C4 EXT WAL�S BASED ON SEPARATION DISTANCE — SEPARATION DISTANCE 5 : >30 FT RATING: 0 HR <br /> � �--, ( ) <br /> i � � -��_� i �►� � i . <br /> v �� <br /> FIRE PROTECTCO�J SYSTEMS (6) <br /> D — — — — — � — � PORTABLE FIRE EXTINGUISHERS: 50FT MAX SPACING (NFPA 10 CHAPTERS 5 �C 6) <br /> AUTOMATI� FIRE PROTECTION SYSTEM (6): REQUIRED FOR H-4 GROUP OCCUPA�ICY . <br /> VEHICLE IMPACT PROTECTION: REQUIRED (IFC 312) <br /> EXPLOSION CONTROL: NONE REQUIRED (IFC 911 ) <br /> FOAM FIRE PROTECTION: NONE REQUIRED (IFC 5704.2.9.2. 1 ) <br /> LABELING AND SIGNAGE: REQUIRED (OSHA 1910) <br /> � <br /> E X I T P �A I� (1) HMEX: THE HAZARDOUS MATERIAL EXPERT ASSISTANT, VERSION 6 — FLUER, INC. , <br /> SCALE: 1/8"=1 �—O�� ' V (2) IBC TABLE 307.1 — MAXIMUM AL�OWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS <br /> IBC 414.6 — OUTDOOR STORAGE, DISPENSING, USE � <br /> IFC 3104.2.2 — SEPARATfON DISTANCE <br /> IFC 2701, 2703, 2705, & 2705.3 — HAZARDOUS MATERIALS, USE, DISPENSING AND HANDLING <br /> IFC CHAPTER 50 — COMBUSTIBLE LIQUIDS <br /> (3) IBC CHAPTER 3 — USE AND OCCUPANCY CLASSIFICATION, <br /> (4) IBC CHAPTER 5 — GENERAL BUILDING HEIGHTS AND AREAS, <br /> TABLE 504.3 — ALLOWABLE BUILDING HEIGHT <br /> .� TABLE 504.4 — ALLOWABLE NUMBER OF STORIES <br /> Q TABLE 506.2 — ALLOWABLE AREA r\ EY P I�A� ` <br /> � TABLE 508.4 — REQUIRED SEPARATION OF OCCUPANCIES <br /> 0 <br /> � (5} !BC CHAPTER 6 — TYPES OF CONSTRUCTION � <br /> � <br /> ! TABLE 601 — FIRE—RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS • <br /> � TABLE 602 — FIRE—RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE 8' 4� O 4� 8� 16� <br /> � <br /> N <br /> � (6) IBG CHAPTER 9 — FIRE PROTECTION SYSTEMS <br /> � IBC 903.2.5 — AUTOMATIC SPRINKLER SYSTEMS SCALE: 1/8��=1 �-0�� <br /> � <br /> 0 <br /> a (7) IBC CHAPTER 10 — MEANS OF EGRESS <br /> i <br /> U <br /> � � - ante . <br /> 100 % DESIGN ISSUED FOR CO�ISTRUCTION C <br /> SYM REVISION B`( APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ���� accEP-raB���n SERGIYENKO 3.2o.,s gUILDING C4DE SUMMARY AND EXIT PLAN <br /> �z�G=sx��t�� THIS DESIGN AND/OR CHECK ORIG 3.20.18 <br /> RcxxT�c� SPECIFICATION IS APPROVED WEAKLEY 3.20.18 sHEEr <br /> � ✓ ENc�NEER TITLE WASTEWATER TREATMENT PLANT <br /> ���,�� APPROVED BY DEPT. DATE NAVARRO 3.20.18 �� <br /> CHECKED <br /> � cr�Aa�es e vou � MINNICK 3.20.18 B U I L D I N G 45'O V <br /> STATE OP WASHINGTON APPROVED JOB N0. COMP N0. , <br /> WEAKLEY 3.20.18 <br /> HARRISE� 3.20.18 ARCHITECTURAL MASTER COL. A—D/1 -6 EVERETT, Wq DWG N0. 45-0$—A� Y <br />