Laserfiche WebLink
CODE SUMMARY <br /> OWNER: BOEING DATE: SEPTEMBER 2016 G E�I E RA� �I OT E S <br /> 1 O. 1 O'2 PROJECT NAME: BOEING WASTEWATER TREATMENT P�ANT 45-08 PROJECT NO.: 10507612 1. ADJACENT BUILDINGS AND STRUCTURES TO SULFURIC TANK IN ' <br /> OUTDOOR STORAGE AREA ARE REQUIRED TO BE SEPARATED BY A <br /> PROJECT LOCATION: EVERETT, WASHINGTON DISTANCE OF 2Q FEET OR PROVIDED WITH A 2-HQUR FIRE BARRIER <br /> 6'-6" WALL THAT EXTENDS 30 INCHES ABQVE AND TO TNE SIDES OF TNE ` <br /> A AREA/BUILDING : OUTDOOR STORAGE AND PROCESS AREA STORAGE TANK (IFC 2015 6003.2.3). <br /> � • . : <br /> � 2–HouR coNCRerE GOVERNING CODES <br /> � FIRE BARRIER WALL � � � � <br /> i � SEE STRUCTURAL I FIRE EXTINGUISHER, lYF OF 4 BUILDING CODE: 2015 INTERNATIONAL BUILDING CODE (IBC) WITH STATE OF WASHINGTON AND CITY OF EVEREI�T AMENDMENTS ACCESIBLITIY CODE: N/A <br /> 0O DRAWIN S <br /> 0 <br /> � O FIRE CODE: 2015 INTERNATIONAL FIRE CODE (IFC} WITH STATE OF WASHINGTON AND CITY OF EVERETI� AMENDMENTS NFPA CODE: 30, 70 & 7Q4 R E F E R E�1 C E D R AW I N G S <br /> ` <br /> � SULFURIC - ENERGY CODE: 2015 INTERNATIONAL ENERGY CODE (IEC) WITH WASHINGTON AMENDMENTS AND PUGET SOUNDS ENERGY CODE OTHER: 2009 UPG, IMC & NEC WITH WA AMENDMENTS . <br /> TANK LFURIC A ID SEE DWG. 45-08-1A11, FOR FLOOR PLAN <br /> Q � i I OSING PU P SEE DWG. 45-08-A61, FOR EXTERIOR ELEVATIONS <br /> o � {1000 GAL) , SEE DWG. 45-08-RFA161, FOR ROOF PLAN : , <br /> � HAZARQOUS MATERIA�S ( 1 ) (2) <br /> � 25 FT EXIT TRAVEL DISTANCE NFPA 704 RATING HAZARD PROPERTIES � <br /> CHEMICAL CAS N0. CONCENTRATION QUANTITY REMARKS <br /> — ,.. .� <br /> � [ HEALTH FLAMMABILITY REACTIVITY SPECIAL PHYSICAL HEALTH <br /> "� �- SULFURIG ACID 57-55-6 93� 1,000 GAL 3 0 2 � WR2 COR TQX OUTDOOR STORAGE <br /> � � W WEATHER PROTECTION <br /> EYE WASH � FERRIC SULFATE 10028-22-5 3Q-60% 1,500 GAL 2 0 Q - - IRR OUTDOOR STORAGE <br /> o SHOWER f W WEATHER PROTECTION .� <br /> L <br /> V � <br /> •N <br /> � i ER I S L AT FERRIC USE AND OCCUPANCY CLASSIFICATION/ AL�OWABLE AREA AND HEIGHT (3) � � <br /> W Q 1500 GAL DOSING <br /> _ ' ' _ (T-540) _ PUMPS ' CONSTRUCTION ALLOWABLE ACTUAL ALLOWABLE AUTOMATIC ACTUAL AREA/ <br /> � � �–� A.g OCCUPANCY GROUP AREA MODIFICATION . <br /> O AND DESCRIPTION TYPE HEIGHT HEIGHT AREA SPRINK�ER AGTUAL AREA A�LOWABLE AREA FRONTAGE INCREASE <br /> (6) RAT10 <br /> EYE WASH / IIB - FT 24 FT NOT <br /> NO OCCUPANCY CLASSIFICATION <br /> SHOWER OUTDOOR STORAGE (NON- RATED) - STORIES 1 STORY 1,500 SF RE4UIRED 1,350 SF 0.9 N/A <br /> O W/WEATHER PROTECTION <br /> � MEANS OF EGRESS (7) � <br /> MEDIA FILTER ` <br /> FEED PUMP � <br /> MAX FLOOR TOTAL COMMON <br /> � ROOM OR FUNCTION PATN OF EXITS EXITS EXIT ACCESS <br /> AREA NAME OF SPACE AREA PER OCCUPANT TRAVEL REQ'D PROVIDED TRAVEL DIST STAIRWAYS <br /> OCCUPANT LOAD DISTANCE <br /> SLUDGE PURGE <br /> PUMP UTDOOR STORAGE AND PROCESS AR MECHANICAL 300 3 1Q FT 1 1 25 FT N/A <br /> - UP � EQUIPMENT <br /> � MEDIA FILTER <br /> FEED TANK OUTDOOR STORAGE <br /> (1000 GAL) AND PROCESS AREA > QCCUPANCY SEPARATION (4): NONE REQUIRED FIRE RESISTANCE RATfNG OF STRUCTURA� ELEMENTS (5): 0 <br /> SLUDGE RECYCLE . <br /> Pu"'P EXT WAL�S BASED ON SEPARATION DISTAN�E (5) — SEPARATION DISTANCE: 6 FT RATING: 0 HR <br /> . <br /> — — — — C. 1 FIRE PROTECTION SYSTEMS (6) . <br /> • - - - <br /> i PORTABLE FIRE EXTINGUISHERS: 50�T MAX SPACING (NFPA 10 CHAPTERS 5 8e 6) <br /> AUTQMATIC FIRE PROTECTION SYSTEM (6): NONE REQUIRED <br /> VEHICLE IMPACT PROTECTION; REQUIRED (IFC 312} <br /> EXPLOSION CQNTROL: NONE REQUIRED (IFC 911 ) <br /> � FOAM FIRE PROTECTION: NONE REQUIRED (IFC 5704.2.9.2. 1 ) . <br /> � LABELING AND SIGNAGE: REQUIRED (OSHA 1910) ` <br /> I r� ��1 � - <br /> � F�OCCULATING (1) HMEX: THE HAZARDOUS MATERIAL EXPERT ASSISTANT, VERSION 6 - FLU�R, INC. <br /> � CIARIFIER � <br /> �_������--L� (2) IBC TABLE 307.1 - MAXiMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS <br /> IBC 414.6 - OUTDOOR STORAGE, DISPENSING, USE <br /> t IFC 31 Q4.2.2 - SEPARATION DISTANCE <br /> ` o � CLARIFIER ACCESS IFC 2701, 2703, 2705, & 2705.3 - HAZARDOUS MATERIALS, USE, DISPENSING AND HANDLING <br /> STAIR ANQ PLATFORM IFC CHAPTER 50 - COMBUSTIBLE LIQUIDS <br /> (3) IBC CHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION, . <br /> � <br /> � (4) IBC CHAPTER 5 - GENERAL BUILDING HEIGHTS AND AREAS, <br /> .D. .a. TABLE 504.3 - ALLOWABLE BUILDING HEIGHT � <br /> TABLE 504.4 - ALLOWABLE NUMBER OF STORIES <br /> • • • • � TABI�E 506.2 - ALLOWABLE AREA <br /> TABLE 508.4 - REQUIRED SEPARATION OF OCCUPANCIES <br /> (5) IBC CHAPTER 6 - TYPES OF CONSTRUCTION <br /> TABLE 601 - FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS <br /> TABLE 602 - FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED GN FIRE SEPARATION DISTANCE <br /> (6) IBC GHAPTER 9 - FIRE PROTECTION SYSTEMS <br /> IBC 903.2.5 - AUTOMATIC SPRINKLER SYSTEMS , <br /> (7) IBC CHAPTER 10 - MEANS Of EGRESS <br /> EX IT P �AN <br /> SCALE: 1/4"=1 '-0" � � <br /> �, <br /> 3 <br /> 'D <br /> I <br /> r� <br /> ¢ <br /> I _ <br /> � <br /> � KEY P �AN <br /> 0 <br /> � <br /> � <br /> � <br /> , . <br /> � <br /> � 4' 2' Q 2' 4' 8' <br /> � <br /> N <br /> � ' <br /> � <br /> / <br /> � <br /> � SCALE: 1/4"=1 '-0" <br /> � <br /> 0 <br /> ; <br /> 3 <br /> a <br /> / <br /> U <br /> � � _ tantec _ <br /> 100 /o DESIGN ISSUED FOR CONSTRUCTION <br /> � <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN A E SUBTITLE CURREN7 REVISION SYMBOL DATE ' <br /> ACCEPTABI�ITY NAVARRO 3.20.18 <br /> - ���7� TH►S o�S��N ANo�oR C ECKED CODE SUMMARY AND EXIT PLAN ORIG 3.20.18 <br /> REGI3TERED WEAKLEY 3.20.18 SHEET <br /> � RC�TECT sPEci�cATioN is ,aPPRovEQ WASTEWATER TREATMENT PLANT � . <br /> ENGlNEER TITLE <br /> �OE,�� APPROVED BY DEPT. DATE NAVARRO 3.20.18 � _ � <br /> CHECKED � <br /> c�AR��s E vou�c MINNICK 3.20.18 <br /> - $mp�� �F ����z��Ta� APPROVED OUTD00� STORAGE AREA JOB N0. COMP N0. <br /> WEAKLEY 3.20.18 <br /> � APPROVED DWG N0. <br /> HARRIS 3.2o.�s ARCHITECTURAL MASTER EVERETT, WA 45-08—A3-1 <br />