Laserfiche WebLink
� <br /> 6 5 4 � 2 1 � <br /> GEf� ERA� �IOTES . <br /> 1. VERIFY ALL EXISTING CQNDITIONS BEFORE COMMENCING WORK. <br /> NOTIFY THE ENGINEER IN WRITING OF ANY EXISTING CONDITIONS � <br /> THAT DIFFER FROM THOSE SHOWN ON THE DRAWINGS. <br /> 2. DRAWINGS SHALL NOT BE SCALED. GRAPHIC SCALES ARE <br /> INCLUDED ON THE DRAWINGS FOR CONVENIENCE ONLY. WHERE <br /> DIMENSIONS SHOWN IN THE DRAWINGS CONFLICT, LARGER SCALE <br /> DRAWINGS SHALL HAVE PRECEDENCE. <br /> 3. PART}TIONS ARE PARALLEL OR PERPENDICULAR TO COLUMN LINES '� <br /> 3 UNLESS NOTED OTHERWISE. <br /> 1 A10 A60 1 4. NOiES TO "ALIGN" SHALL MEAN TO ALIGN THE FINISHED FACE OF ' <br /> 1 A10 S450 THE PARTITION OR OTHER ITEM WITN THE ADJACENT FINISH FACE <br /> OF THE EXISTING ELEMENT, UNLESS DE7AILED OTHERWISE. SUCH ; <br /> 74'-0� ALIGNMENTS SHALL HAVE PRECEDENCE OVER DIMENSIONED <br /> LOCATIONS. <br /> 18'-11 /2" 18'- 2" 18�-11 1/2" 15' 0 /4" <br /> 5. CONTRACTOR IS RESPONSIBLE FOR THE VERIFICATION AND <br /> 36'-1" COORDINATION OF THE WORK OF ALL TRADES, TO ASSURE <br /> COMPLIANCE WITH THE CONTRACT DOCUMENTS. <br /> 21'-5 1/2" 6. SEE GENERAL NOTES AND CONSTRUCTION NOTES ON INDIVIDUAL - <br /> DRAWINGS FOR ADDITIONAL REQUIREMENTS. ` <br /> . + + + + . + + + � � � + . � + � .. + . � .. + � + + + � � � <br /> 10'-6" ` <br /> � � � _ � + + + � + + + t + t + + { • + + � + + � + � a ¢ • + + 7. DIMENSIONS SHOWN ARE TO THE FACE OF FINISH UNLESS � <br /> , � « . . , + + , .. , .. t + � .« + + . ,. .. + , , . � , � + .« <br /> 3'- " OTHERWISE NOTED. <br /> EY WASH�SHOWER <br /> ST ION— W� OVERHEAD ROLLUP DOOR W3 <br /> _- W2 A <br /> � BUILDING D E S K <br /> SUMP (P-801, _ � � 30X60 <br /> � r � 1--UVL , <br /> ) BOLLARD, IYP., ,�, <br /> Q; <br /> � B � SEE o \ M <br /> ;r, � , � � �- � O F F I C E�.C O N T R O L R O O M r <br /> `° � 16'X20' <br /> CAUSTI TANK AGID TANK 1 A10 C500 a, � 1 1 A4 NG PAD 3�X11'-6" <br /> 200 GAL R <br /> (T- 30) tT- �0) S12 I U . <br /> � PAC �TANK SULFIT� TANK ' '� <br /> �n 100 — <br /> �" (T- 40) HYDROGEN PEROXIDE <br /> � t�- 20) TANK 1 A10 A11 Q <br /> �' , S� „ 4 � � � X � ESK � CONSTRUCTIOf� I� �TES <br /> N 5 -$ t/2 � g � „ � � 30X60 � <br /> 2 � � � � S1, S6 W2 � 1� REMOVE EXISTING WIND�W. �, <br /> 1A10 A502 S10 S11 <br /> i, � <br /> w -- � REMOVE AND SAVE EXISTING DOOR, FRAME � <br /> = p S� 0 AND DOOR HARDWARE BETWEEN MCC AND <br /> ' � � � �s'-o" PROCESS AREA. : <br /> i � . .. . . . . . . . . . <br /> � � ) U <br /> SLOPED S� F 6 -� CABINETS, SEE 2 3� REMOVE WALL BETWEEN OFFICE AND MCC <br /> ASPHALT DRIVE 1A1Q A504 ROOM TO RELOCATE EXISTING DOOR, FRAME <br /> � <br /> � AND HARDWARE. COORDINATE W/ <br /> N SINK MECNANICAL AND ELECTRICAL. <br /> FILTER PRESS � <br /> (F�T-s�o} - � SEE MECHANICAL DRAWINGS FOR <br /> BOLLARD> nP., BACKGROUND CHANGES ASSOCIATED WITH <br /> ; SEE ,� MECHANICAL EQUIPMENT IN PROCESS AREA. <br /> ; . <br /> ' 1 A10 C50Q S�oPE s� _ 2 � <br /> EYEWASHfSHOWER � MCC 2 5� CORRECTED DOOR LOCATION. = <br /> ; 1 S2 STATION - S 0 S20 � 16 X 10 1 A10 A60 <br /> � 1A10 A60 PROCESS AREA � 11 B4 x � GORRECTED SECTION CUT LOCATION. <br /> 11A1 � �� � � 7 VERIFY 1 HOUR FIRE SEPARATION WALL <br /> � O V E R H E A D R O L L U P D O O R A N D H O O D 16 -0 � � <br /> ; CONSTRUCTION FOR EXISTING WALL AND <br /> ' 5'-7 1/4" 6�_��� B PENETRATIONS. REMOVE EXISTING � <br /> , j N D NQNCOMPLIANT WALL ASSEMBLY AND <br /> � U PENETRATION INSTALLATIONS. , <br /> P FUTURE CANOPY g� <br /> Q (OWNER PROVIDED) 8 ' REMOVE AND SAVE EXISTING DOOR, FRAME <br /> AND DOOR HARDWARE BEfWEEN OFFICE � <br /> POLYMER S UDGE PUM p� C AND PROCESS AREA. <br /> 17'-0 1/2" <br /> � 4 coNc <br /> TA L <br /> "' . X7.7 <br /> �� �r, SLUDGE HOLDING - 10 <br /> 3 COUNTER-TOP <br /> TANK 5 0o cA� MAINTENANCE AREA . <br /> 16'X23.5� SHELVES <br /> 11C4 � <br /> 6'-9 1/4" �p " /- o <br /> _�� <br /> DEFOAMER F M � <br /> OSI DR, M DESK <br /> MIX TA �ZONE (OWNER PROVIDED) <br /> S <br /> ? MIX TANK MIX TANK �i � <br /> � #1 10 0 GAL �2 10 0 GA� (T- 3 300 GAL � � <br /> � — - - (T- 10) � P 401 M � • <br /> � � <br /> �- K EY P �A�l <br /> � � � � �. - .� _ � <br /> i � ;' � �=T_ _� ' � rn <br /> � "' � � RjF OWNER FURNISHED <br /> -5 1/2" 7'- ' S'-8 1/ „ g'-3 1 2 7'-� - /4" 4'-6 1/2" <br /> s2o 4, 2, � 2, 4, 8, <br /> 3 <br /> D <br /> , <br /> � 7 1/2" 1�-3 1/4" SCALE: 1/4"=1 '-0" <br /> j CAGED LADDER 4 CONCREfE,� 5 ` <br /> � ABOVE <br /> /� SEE CIVIL � <br /> 1A10 A60 �I RST F�00 R P �A�I � I 1A10 A110 3 <br /> � _ „ , ,, ta nte c a <br /> � 100 /o DESIGN ISSUED FOR CONSTRUCTION SCALE: 1/4 -1 -0 iv 1A10 A502 ,0�-6�� REMOVAL N ,: <br /> � <br /> � <br /> Q <br /> SYM REVISION BY APPROVED DATE SYM REVISION B`( APPROVED QATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE � <br /> ACCEPTABILITY SERGIYENKO 3.20.,8 FIRST FL�OR PLAN `� <br /> 1 U677 THIS DESIGN AND/OR CHECKED 3.ZO.�H o <br /> A WWTP-ISSUED FOR CONSTRUCTION RECORD 10011818 URS GEMZA 11.14.12 ����S��R��' SPECIFICATION IS APPROVED W�KLEY 3.20.18 SHEEf � <br /> 8��`��� R��I���� APPROVED BY DEPT. DATE NAVARRQ 3.20.�8 TITLE WASTEWATER TREATMENT PLANT � <br /> B WWTP - MODIFICATIONS MWH NAVARRO 12.05.16 1 A 10 R <br /> ,�- <br /> � � MINNICK 3.20.18 M <br /> ����L�s� �°u � B U I L D I N G 45-08 JOB N0. COMP N0. � <br /> sTax�� oF wasxsx�xorr APPROVED <br /> �� ` WEAKLEY 3.20.18 Y <br /> � � � � ,aPPRovE� ARCHITECTURAL MASTER COL. A-D 1 -6 EVERETT, WA °wc No. 45-OS-1A10R <br /> NARRIS 3.20.18 � <br />