Laserfiche WebLink
LOUVER SCHEDULE AIR IN�ET �C OUTLET SCHEDULE <br /> BASIS OF DESIGN <br /> NOMINAL SIZE MAX P.D. TAG PURPOSE TYPE NECK SIZE CFM FINISH NC BORDER TYPE REMARKS <br /> TAG PURPOSE INSTALLATION TYPE ��N� MINIMUM FREE AREA CFM (IN WC) NIANUFACTURER AND MODEL REMARKS (IN.) �FR Mo�E� $"� <br /> LV-4 HYDRAULIC PUMP AIR EXHAUST WALL 14.5x14.5 55% 680 0.15 RUSKIN ELF6375—DXH 1, 2, 3 SG1 TO SUPPLY GRILLE 96x48 25,00o ALUMINUM BLADES 37 STEEL TITus �32—RS <br /> LV-5 HYDRAULIC PUMP AIR INTAKE WALL 14.5x14.5 55% 680 0.15 RUSKIN ELF6375—DXH 1, 2, 3 2 � <br /> LV-6, 7 CONTROL ROOM AIR INTAKE / EXHAUST WALL 14x14 55% 400 0.15 RUSKIN ELF6375—DXH 1, 2, 3 RG1 JOINED W/ ALUMINUM ARRAY 6 GRILLES IN WALL TO EQUAL 132 INCHES WIDE BY 88 <br /> LV-8,9 HYDRAULIC PUMP ROOM MAKEUP AIR WALL 48x66 55� 11,000 — Tgp 1,4 <br /> TO 6 RETURN GRILLE 44x44 7,833 WHITE 28 MULLIONS TITUS 355-ZFL INCHES HIGH <br /> LV-10,11 HYDRAULIC PUMP ROOM EXHAUST AIR WALL 48x66 55% 11,000 — (Tgp� 1,4 <br /> NOTES: 1 . COLOR TO BE SELECTED BY OWNER. EG1 EXHAUST GRILLE 12x12 500 WHITE 18 WAL� MOUNTED TITUS 350-RL <br /> 2 PROVIDE WITH FLANGED FRAME AND BIRD SCREEN. <br /> 3. ALUMINUM LQUVER THROW 73'-0" @ 150 FPM, 90'-0" � 100 FPM, 127'-0" � 50 <br /> 4. ACTUAL SIZE, CFM, MAX P.D., MANUFACTURER AND MODEL WILL BE SELECTED BY BOEING. SD-1 DRUM LOUVER DIFFUSER 70x15 5,000 WHITE 38 ALUMINUM TITUS DL FPM TERMINAL VELOCITY AT 0' DEFLECTION <br /> SD-2 SUPPLY AIR DIFFUSER 10"� SEE PLAN WHITE 32 ALUMINUM TITUS TDC <br /> S P�IT C 0 N D E�1 S I N G U N I T S C H E D U L E (VR F) R�-� RETURN AIR GRILLE 22x22 1,270 WHITE 32 ALUMINUM TITUS 50F <br /> NOMINAL COOLING CAPACITY HEATING CAPACITY ELECTRICAL SHIPPED <br /> UNIT N0. LOCATION SERVICE EER/IEER BASIS OF DESIGN REMARKS RG-8 REfURN AIR GRILLE 14x14 400 WHfTE 32 ALUMINUM TITUS 50F <br /> TON (BTU/HR) (BTU/HR) VOLTS PH MCA MOCP WEIGHT (LBS) <br /> CU-A OUTDOOR CONTROL ROOM 12 12.5 / 21.2 144000 160000 460 3 21 35 706 MITSUBISHI PUHY-P144YLMU 1,2 <br /> NOTES: 1. MOUNT ON 4" CONCRETE PAD MINIMUM 6" WIDER IN EACH DIRECTION THAN CONDENSING UNIT. C O N Q E I V S I N G U N IT S C H E d U LE <br /> 2. DISCONNECT BY ELEC CONTRACTOR. ' <br /> � PAIRED UNIT SIZE SYSTEM LIQUID SUCTION ELECTRICAL SOUND WEIGHT <br /> UNIT N0, AREA SERVED UNIT MAKE MQDEL � REMARKS <br /> (TONS) SCOP (�N.) (IN.) VOLTS PH MCA MOCP d6(A) (LBS. , <br /> CU-1 SYSTEMS ROOM FCU-1 LIEBERT PFHZ37AL 3 2.59 1/2 7/8 208 1 22.3 35 57 351 1,2 <br /> SPL T FAf� C01� UNIT SCHEDU�E NOTEs: <br /> 1. UNIT TO BE MOUNTED OUTSIDE ON CONCRETE SLAB <br /> UNIT AREA MIN OSA FAN ELECTRICAL SHIPPED OUTDOOR 2. REFRIGERANT R-407C, CHARGED TO 426 OZ <br /> FILTER BASIS OF DESIGN REMARKS <br /> N0. SERVED (CFM) CFM ESP VOLTS PH MCA MOCP WEIGHT (LBS) UNIT N0, <br /> FCU-A1 CONTROL ROOM 200 215Q 0.8 208 1 7.7 15 MERV 13 214 MITSUBISHI PEFY-P72NMHSU CU-A 1, 2, 3 <br /> FCU-A2 CONTROL ROOM 200 2150 0.8 208 1 7.7 15 MERV 13 214 MITSUBISHI PEFY-P72NMHSU CU-A 1, 2, 3 FAN CO I L U N IT SCN ED U LE r • <br /> NOTES: 1, INCLUDE MANUFACTURER DRAIN PUMP MODEL PAC-KE05DM-F AND CONDENSATE OVERFLOW SWITCH. COOLING CQIL TOTAL FAN CFM ELECTRICAL WJ-. <br /> UNIT N0. AREA SERVED MAKE MODEL TYPE (gTU/H} (RANGE) VOLTS PHASE (LBS) REMARKS <br /> 2. INCLUDE MANUFACTURER FILTER BOX WITH 4" MERV 13 FILTER MODEL FBH4-4. ' <br /> 3. PROVIDE 24" LONG FULL SIZE PLENUM ON SUPPLY SIDE OF FAN COIL. FCU-1 SYSTEMS ROOM LIEBERT MMD36E SPLIT SYSTEM 33,800 1250 208 1 225 1,2,3 <br /> 4. PROVIDE BACNEf INTERFACE FOR SITE HONEYWELL DDC SYSTEM. NOTES: <br /> 1. ELECTRICAL DISCONNECT BY ELECTRICAL CONTRACTOR. <br /> ENERGY RECOVERY VENTILATOR SCHEDULE 2. PROVIDE WITH WALL MOUNTED THERMOSTAT. <br /> 3. ECONOMIZER EXCEPTION: COOLING UNITS AND SPLIT SYSTEMS WITH A TOTAL COOLING CAPACITY RATED IN ACCORDANCE WITH SECTION C403.2.3 OF LESS THAN 33,000 BTU/H <br /> SUPPLY FAN EXHAUST FAN SUMMER SUPPLY WWTER SUPPLY COOLING/HEATING ENERGY ELECTRICAL <br /> UNIT N0. LOCATION MAKE & MODEL FILTER OPER WT. (LBS.) REMARKS �`�' <br /> CFM ESP HP BHP CFM ESP HP BHP * DB * DB EFFICIENCY VOLTS PH HZ FLA ° , <br /> ERV-1 CONTROL ROOM ALDES E1100-FI 400 0.5 (2� 0.4 0.77 400 0.5 (2� 0,5 0.77 77.4 F 64.7 F 59.3% / 58.5% 120 1 60 10.5 MERV 8 230 1 <br /> ELECTRIC UNIT HEATER SCHEDULE . <br /> * WORST CASE DESIGN SUMMER AMBIENT TEMPERATURE 85F / 69F (DB/WB) AND WINTER 23F. MARK LOCATION MAKE MODEL ARRANGEMENT KW /VOLT/ PH FAN WGT. REMARKS <br /> NOTES: <br /> CFM VOLTSfPH <br /> 1. UNIT SHALL BE PROVIDED WITH A BASIC PROGRAMMABLE CONTROLLER MOUNTED ON SPACE WALL. U - T SF Z - H L .5 4 5 80 3 1 <br /> UH-2 HYDRAULIC PUMP ROOM REZNOR EGEB-7 HORIZONTAL 7,5 / 480 / 3 625 480/3 37 1, 2, 3 <br /> N(}TES: <br /> B 1, PROVIDE FAN GUARD, WALL BRACKETS � �.X <br /> 2. HEATER CONTROLLED BY EMCS <br /> 3. BOTTOM OF UNIT SHALL BE AT LEAST 8 FOOT ABOVE FINISH FLOOR <br /> B , <br /> ..=�,t <br /> .:�t. <br /> .;.�. <br /> :_� <br /> ISSUE FOR CONSTRUCTION <br /> COFFMAN . <br /> N G I N E E R S <br /> 1 1� ■ ^/1 ■n 0 /� f'� 1601 Fifth Avenue,Suite 900�Seattle,WA 98101 ` ¢� <br /> £. . <br /> L L L �,, ph 206.623.0717�fax 206.624.3775 < <br /> coffman.com , <br /> r <br /> LASTING creativity�results(relationships � <br /> � <br /> K <br /> C <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPRQVED DATE L S ACCEPTABILITY G ROUTH �05 26.15 SUBTITLE CURRENT REVISION SYMBOL DATE • <br /> _ ��� S°�' TH,S oES,�N ANo oR �HE�KEo — MECHANICAL EQUIPMENT SCHEDULES W4440664 B � 2.�2.� 6 � <br /> E D C S T A T I C T E S T F A C I L I T Y W 3 0 9 9 7 1 5 C E I M S 1 Q.0 2.1 5 ti � I�� � M.S O T U R A 0 5.2 6.1 5 � <br /> � SPECIFICATION IS APPROVED SHEET <br /> A EDC STATIC TEST FACILITY — AS—BUILTS W3099715 CEI MS 09.01.16 ���,H�� '� , o �" INEER TITLE EDC STATIC TEST FACILITY — PHASE 2 '� <br /> � �2, APPROVED BY DEPT. DATE COFFMAN 05.26.15 « <br /> B EDC STATIC TEST FACILITY — PHASE 2 W4440664 CEI MS 12.22.16 cHECKE� � <br /> � BUILDING 45 012 � <br /> ro 36611 APPROVED � JOB N0. COMP NO. <br /> ��CIST�,�9 �,� W3099715 Q <br /> �'sSjoNA� ��� APPROVED MECHANICAL MASTER EVERETT, Wq °wc No. 45-012—M2B <br /> <�� <br />