41 <br /> Brad ()lion <br /> From: Tony Lee <br /> Sent: Thursday, February 12, 2004 07:38 <br /> To: Brad Olson <br /> Subject: FW: 2818 Wetmore <br /> Original Message <br /> From: Rick Robinson <br /> Sent: Tuesday,February 03,2004 3:33 PM <br /> To: Steve Miller <br /> Cc: Tony Lee; Brad Olson <br /> Subject: FW: 2818 Wetmore <br /> Steve, <br /> Here's my list with Brad's below. There is some serious cost involved here. Rick <br /> Original Message <br /> From: Rick Robinson <br /> Sent: Tuesday,February 03,2004 15:31 <br /> To: Brad Olson <br /> Subject: RE: 2818 Wetmore <br /> Brad, <br /> I went there today and found the following with respect to UFC App I-A <br /> 1. Stair construction seemed fine throughout. I didn't find any trip hazards or moving treads. I didn't <br /> measure rise and run per I-A Section 2.2, but I'm sure it's not out of spec. Stair construction is a non- <br /> issue. <br /> 2. Basement definitely needs a sprinkler per UFC App. I-A. I'm not sure making it into a crawl space <br /> is logical except maybe in the short run for TCO. Sprinkler installation in the timeframe specified by <br /> our ordinance seems workable. <br /> 3. Elevator vertical shaft probably needs work, but I didn't inspect it closely. One-hour fire resistive <br /> construction needs patching in several areas in the building, so the shaft needs a good look. <br /> 4. Egress from third (top) floor has two stairways. This could be made to work as two separate means <br /> of egress. Perhaps opposing 1-hr doors in the middle of the corridor to provide separation. <br /> 5. The fire escape from the third floor to the alley does not meet App I-A requirements. <br /> a. Its access is through an intervening room. Lose the room. <br /> b. Fire escape design needs to be verified by an engineer for App I-A Section 2.4, paragraph <br /> 2. compliance in design and weight load carrying ability before it can be used/counted as a compliant <br /> means of egress. <br /> 6. Second floor east office/storage area square footage needs to be measured to ensure occupancy <br /> is less than 10 persons to avoid construction of a second means of egress from this area. <br /> 7. Second floor west, "Bar" needs a second means of egress as it is large enough for an occupancy <br /> level greater than 10 persons. I'm willing to look at a fire escape design as the drop is minimal. <br /> 8. One-hour rated self-closing fire doors are required for: <br /> a. East basement stairway door into Wetmore entry way. <br /> b. East stairway doors leading up to the 2nd and 3rd floors <br /> c. Door leading from 2nd floor East office into east stairway <br /> d. Door leading from 2nd floor east storeroom (next to office door) <br /> e. Door leading from 3rd floor east room <br /> f. Door leading from 3rd floor west room/kitchen <br /> g. Door leading from 2nd floor west "Bar" into west stairway <br /> h. Door leading from west stairway into Main floor restaurant area. <br /> i. Door leading from west basement stairs into main floor restaurant area <br /> 1 � <br />