Laserfiche WebLink
GENERAL LEGEND GENERAL ABBREVIATIONS PLUMBI �IG ABBREVIATIONS <br /> ABV ABOVE LBS/HR POUNDS PER HOUR AW ACID WASTE L LAVATORY , <br /> N NORTH ARROW AD ACCESS DOOR LF LINEAL FEET A AIR, COMPRESSED AIR <br /> ADDN ADDITION, ADDITIONAL LO LOW MV MEDICAL VACUUM <br /> AFF ABOVE FINISHED FLOOR LTG LIGHTING BOP BO170M OF PIPE , <br /> X ALT ALTERNATE LVG LEAVING NPW NON—POTABLE WATER <br /> X DETAIL, DRAWING REFERENCE AP ACCESS PANEL LWT LEAVING WATER TEMPERATURE CI CAST IRON NO NITROUS OXIDE; NUMBER <br /> APPROX APPROXIMATELY CF CHEMICAL FEED N NITROGEN <br /> ARCH ARCHITECT; ARCHITECTURAL MAT MATERIAL CIRC CIRCULATING <br /> — AUX AUXILIARY MAX MAXIMUM CW CITY WATER; DOMESTIC COLD WATER 0 OXYGEN <br /> SECTION REFERENCE MBH THOUSAND BRITISH THERMAL UNITS PER CO CLEAN OUT <br /> — BAL BALANCING HOUR CA COMPRESSED AIR PC PUMPED CONDENSATE <br /> BLDG BUILDING MCC MOTOR CONTROL CENTER PIW PUMPED INDUSTRIAL WASTE <br /> 1,�- CONSTRUCTION NOTE BSMT BASEMENT MECH MECHANICAL; MECHANICAL CONTRACTOR DI DEIONIZED WATER PLBG PLUMBING <br /> BTU BRITISH THERMAL UNIT MED MEDIUM DW DISTIL�ED WATER PNEU PNEUMATIC <br /> BTUH BRITISH THERMAL UNITS PER HOUR MFG MANUFACTURING DOM DOMESTIC PRV PRESSURE REDUCING VALVE <br /> A REVISION SYMBOL DR DOOR; DRAIN , <br /> MFR MANUFACTURER <br /> CAP CAPACITY MIN MINIMUM; MINUTE DF DRINKING FOUNTAIN RWL RAIN WATER LEADER <br /> � POINT OF CONNECTION CL CENTERLINE MISC MISCELLANEOUS <br /> RECIRC RECIRCULATING <br /> CLG CEILING MTD MOUNTED ES EMERGENCY SHOWER RD ROOF DRAIN <br /> � � BOLD LINE WEIGHT INDICATES NEW WORK CMU CONCRETE MASONRY UNIT MTG MOUNTING <br /> COND CONDENSATE MTL METAL FCO FLOOR CLEAN OUT S SOIL <br /> � � LIGHT LINE WEIGHT INDICATES EXISTING COL COLUMN FD FLOOR DRAIN SS SANITARY SEWER; SERVICE SINK; <br /> CONC CONCRETE N NORTH FOR FUEL OIL RETURN STAINLESS STEEL <br /> � � � � � � � � - SLASHED LINE INDICATES EXISTING WORK TO CONN CONNECT; CONNECTION NA NOT APPLICABLE FOS FUEL OIL SUPPLY SD STORM DRAIN <br /> BE DEMOLISHED CONST CONSTRUCTION NC NORMALLY CLOSED FOV FUEL OIL VENT <br /> CONT CONTINUOUS; CONTINUATION NIC NOT IN CONTRACT FPHB FREEZE PROOF HOSE BIBB UPC UNIFORM PLUMBING CODE � <br /> P L U M B I N G L EG E N D COORD COORD NAT�E NOM NOM NAL Y OPEN; NUMBER ° <br /> G GAS V VENT <br /> NTS NOT TO SCALE GPH GALLONS PER HQUR VA VALVE <br /> VAC VAC U U M <br /> � — � DOMESTIC COLD WATER (CW) � � <br /> AIR VENT, TYPE AS SPECIFIED D DEEP (DIM) HB HOSE BIBB VB VACUUM BREAKER <br /> DEG DEGREE OC ON CENTER <br /> DOMESTIC HOT WATER (HW) �- DIA DIAMETER OD OUTSIDE DIAMETER; OVERALL DIMENSION HW DOMESTIC HOT WATER VTR VENT THRU ROOF <br /> �— � PRESSURE TEMPERATURE TAP HWC DOMESTIC HOT WATER CIRCULATING <br /> , � � / DIAG DIAGONAL; DIAGRAM OPP OPPOSITE <br /> � - - - � DOMESTIC HOT WATER CIRCULATING (HWC) DIFF DIFFERENTIAL W WASTE; WATER; WIDE(DIM) <br /> DIM DIMENSION PD PRESSURE DROP IPC INTERNATIONAL PLUMBING CODE WC WATER CLOSET <br /> TEMPERATURE GAUGE DISCH DISCHARGE PERF PERFORATED IW INDIRECT WASTE WFS WATER FLOW SWITCH <br /> SOIL, WASTE (S,W) DIV DIVISION PERP PERPENDICULAR <br /> � — — — — — — — � VENT (V) DN DOWN PH PHASE JAN JANITOR Y WYE ' <br /> DP DIFFERENTIAL PRESSURE POC POINT OF CONNECTION <br /> �XX--� PIPING IDENTIFIER, SEE ABBREVIATIONS DR DRAIN PRELIM PRELIMINARY <br /> DWG DRAWING PRESS PRESSURE <br /> � ELBOW DOWN PROP PROPERTY; PROPOSAL <br /> EA EACH PS PRESSURE SWITCH <br /> ELBOW UP EFF EFFICIENCY PSI POUNDS PER SQUARE INCH <br /> ELEC ELECTRICAL PSIG POUNDS PER SQUARE INCH GAGE <br /> TEE EM S ENERA Y�M�ANAGEM oT CONTROL SYSTEM PT PRESSURE/TEMPERATURE TAP G E N E RAL N OTES ; <br /> " TEE DN ENT ENTERING <br /> QTY QUANTITY , <br /> � EQ EQUAL 1 . PROVIDE POST CONSTRUCTION COMMISSIONING AND COMPLETION REQUIREMENTS IN ACCORDANCE WITH THE <br /> �---f ►----�I� � TEE UP EQUIP EQUIPMENT R RADIUS; RETURN; RISER 2015 WASHINGTON STATE ENERGY CODE, COMMERCIAL PROVISIONS SECTION C408 AND IN ACCORDANCE WITH <br /> 1 ET EXPANSION TANK RAD RADIATOR THE CONTRACT DOCUMENTS. <br /> ANGLE VALVE EWT ENTERING WATER TEMPERATURE REF REFERENCE <br /> �----���—+ ISOLATION OR SHUT—OFF VALVE NO , TYPE AS SPECIFIED EX, (E) EXISTING REFR REFRIGERATION 2. BALANCE AL� HVAC SYSiEMS IN ACCORDANCE WITH THE 2015 WASHINGTON STATE ENERGY CODE, <br /> � � EXP EXPOSED REQD REQUIRED COMMERCIAL PROVISIONS; GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE <br /> ISOLATION OR SHUT—OFF VALVE NC , TYPE AS SPECIFIED EXPL EXPLOSION RET RETURN CONTRACT DOCUMENTS. <br /> ����� � � RM ROOM <br /> �—v�� THROTTLING VALVE, TYPE AS SPECIFIED F FAHRENHEIT RPM REVOLUTIONS PER MINUTE 3. PROVIDE CONTROLS IN ACCORDANCE WITH THE 2015 WASHINGTON STATE ENERGY CODE, COMMERCIAL ; <br /> FIO FURNISHED 8c INSTALLED BY OWNER PROVISIONS; INCLUDING SECTION C405.2 FOR LIGHTING, C403.3, C403.4, AND C403.6 OR C403.7 AS <br /> BALANCING VALVE FIN FINISHED S SOUTH APPLICABLE FOR HVAC CONTROLS, C403.2.6 FOR VENTILATION, C403.5 FOR ENERGY RECOVERY, AND IN ° <br /> FLEX FLEXIBLE SCHED SCHEDULE ACCORDANCE WITH THE CONTRACT DOCUMENTS. <br /> ���_� FLR FLOOR SECT SECTION <br /> METERING BALANCING VALVE FOIC FURNISHED BY OWNER, INSTALLED BY SF SQUARE FEET 4. ALL HEATING, VENTILATING PIPING AND PLUMBING SYSTEMS, MATERIALS, FABRICATION, INSTALLATION, <br /> ���� CHECK VALVE CONTRACTOR SHT SHEET ALTERATION OR REPAIR SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH THE 2012 INTERNATIONAL <br /> F FP FIRE PROTECTION; FREEZE PROTECTION SIM SIMILAR MECHANICAL CODE, CONTRACT SPECIFICATIONS, SMACNA, HVAC DUCT AND IPC CONSTRUCTION STANDARDS, <br /> �—�`' FOOT VALVE FT FEET; FOOT; FEET OF WATER(PRESS) SOL SOLENOID MANUFACTURER'S INSTALLATION INSTRUCTIONS AND AS SHOWN ON THE DRAWINGS. <br /> SPEC SPECIFICATION <br /> ��'�'�� CONTROL VALVE GA GAGE; GAUGE SPECD SPECIFIED <br /> 3—WAY CONTROL VALVE GCL GENERAL CONTRACTOR ST�D ST�A DARD P L U M B I N G G E N E RAL N OTES <br /> GEN GENERAL STRUCT STRUCTURAL � <br /> ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS SPECIFIED GPM GALLONS PER MINUTE 1 . NO PRODUCTS CONTAINING SILICONE SHALL BE USED ON THIS JOB. <br /> GWB GYPSUM WALLBOARD TBD TO BE DETERMINED <br /> ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS SPECIFIED TD TEMPERATURE DIFFERENTIAL 2. ALL PIPING SHALL CONFORM WITH BOEING DESIGN CRITERIA D38106-02 AND D38106-53 AND ANY OTHER <br /> H HEIGHT; HIGH TEMP TEMPERATURE APPLICABLE BOEING DESIGN CRITERIA. <br /> THROTTLING VALVE (NO), TYPE AS SPECIFIED HOA HAND OFF AUTOMATIC TH TOTAL HEAD <br /> HOR HORIZONTAL THRU THROUGH <br /> THROTTLING VALVE (NC), TYPE AS SPECIFIED HP HORSE POWER TYP TYPICAL <br /> HR HOUR <br /> �—�vF--+ PLUG VALVE HZ HERTZ UBC UNIFORM BUILDING CODE <br /> PRESSURE REDUCING VALVE UL UNDERWRITER'S LABORATORY <br /> '��`�' IBC INTERNATIONAL BUILDING CODE UTIL UTILITY <br /> � �s ID INSIDE DIAMETER <br /> � SOLENOID VALVE IFC INTERNATIONAL FIRE CODE V VOLT <br /> IMC INTERNATIONAL MECHANICAL CODE VAR VARIABLE <br /> �—� ANGLE VALVE(PLAN VIEW) IN INCH VEL VELOCITY <br /> INFO INFORMATION VERT VERTICAL <br /> r--] CAP INSUL INSULATE; INSULATION VOL VOLUME <br /> ��I B�IND FLANGE KW KILOWATT W WATER; WIDE(DIM); WATT <br /> JU' EXPANSION JOINT KWH KILOWATT HOUR W� WITH � <br /> r—�—� REDUCER L LENGTH; LONG (DIM) WT O WEIG�HTT <br /> LAB LABORATORY <br /> I <br /> PRESSURE GAUGE LAV LAVATORY YD YARD <br /> LB POUND YR YEAR <br /> STRAINER <br /> � FSi consulting engineers <br /> �—�I�� UNION PROFESSIONAL STAMP 8c SIGNATURE Seattle, Washington <br /> A REVISIO�R�EAS ONLY ASHINDCATEDED ISSUED F4R CONSTRUCTIUN Solutions �C Service <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE , <br /> �. DANF ACCEPTABILITY DLR GROUP o�.,o.o� ABBREVIATIONS & SYMBOLS LEGEND <br /> '` pF WASy� �� THIS DESIGN AND/OR CHECKED W3347480 07.19.17 <br /> — 40-37 ELEVATOR BOOTHS — RECORD 10854859 C/ROLLUD 09.26.16 c����P�`�" ' y�fo � SPECIFICATION IS APPROVED LTP 07.10.07 SHEET <br /> A 40-37 PAINT CELL SSG SUMP RELIABILITY & SAFEIY W3347480 FSi 07.19.17 BOE,�� � � y APPROVED BY DEPT. DATE ENGINEER TITLE 40-37 PAINT CELL SSG SUMP RELIABILITY 8c SAFETY <br /> CHECKED G 1 <br /> 20290 �Q' <br /> o,� �F��STERE� ��`� APPROVED B U I LD I N G 40�0� 1 JOB N0. COMP N0. <br /> �SS�ONAI N`' 10854859 <br /> 0791 APPROVED ARCHITECTURAL MASTER EVERETT, Wq °wc No. 40-037—G1 <br /> SICXED <br />