My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5117 SEAVIEW WAY 2019-09-19
>
Address Records
>
SEAVIEW WAY
>
5117
>
5117 SEAVIEW WAY 2019-09-19
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2019 3:47:01 PM
Creation date
9/19/2019 3:46:49 PM
Metadata
Fields
Template:
Address Document
Street Name
SEAVIEW WAY
Street Number
5117
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 - <br /> Provide detail /section for deck construction including guard attachment to the deck <br /> struaure <br /> Prvwde required lateral connection per section R507. <br /> Where supported by attachment to an exterior wall, decks shall be positively anchored to <br /> the primary structure and designed ned for both vertical and lateral loads. (R507.1 IRC) <br /> The existing Main Level floor plans shows the stairs a.; 2'-8"wide. The proposed Main Level <br /> fioor plan shows the framing at 3' n"wide.Typically the dimensions on the drawings are to <br /> the face of the framing, As drawn the stairs would be less than the minimum 36 inch clear <br /> dimension:required, Please clarify if the dimensions are to the face: of the framing or <br /> finished dimension, <br /> /The Proposed Basement plan shows the stairs going up to a landing that has the stairs <br /> down .from the main floor encroaching Into the minimum 36 inch wide janding. <br /> \ The stairs in the area that used to be part of the garage are required to have a framed wall <br /> with R-21 insulation in the cavity. The stairs will have to be relocated to accommodate-the <br /> furred framing wall, <br /> ,ori-S ' % =Provide floor framing plan for the revisions made to the stair openings. <br /> Provide section drawing of the stairs to show that a minimum of 61-8" headroom is <br /> maintained over the stairs. Specify all mechanical connections of stair stringer to the <br /> landing and the floor joists. <br /> 1‹.-The as-built plan shows"Existing Bedroom 3"with what appears to be a kitchen sink, stove <br /> and counters.The same space is labeled as Existing Bedroom 3 on the proposed plans but <br /> ( 0 � < has no`egress window and does not have direct access to an exterior door. Please clarify. <br /> The proposed basement floor plan shows a "NEW 9' GARAGE DOOR" and "REPLACE <br /> ('q.�,t� p� CONCRETE <br /> between the slab-on-grade ed l nitheAliiving area/garage,ag Provide detail, Provide minimum R-10 Rid . <br /> s (o' )(The plans show the exterior doors swinging out over the landing, The maximum step down <br /> allowed for this condition is 1-1/2 inches measured from the finished floor to the landing. <br /> ( s <br /> Provide note on drawings showing this requirement. <br /> 4e <br /> Pride minimum 100 CFM exhaust fan in the kitchen vented..to the exterE+ar. Show on <br /> plans. <br /> fy fan size for all source specific ventilation per Table M1507,4 IRC. <br /> 1/Provide minimum 1-3/8"solid core wood door with seif'dbeer betweena garage and the <br /> living area, <br /> If you have any questions on the corrections, please email or call me at(425) 257-8976. <br /> application will be given pri and p <br /> inn reviews will <br /> Upon submittal of the drawings, your app` <br /> re si~lf'rin - , til required s ibmt�ls shall be sufficient detail int WIth alnd contain l ad ted s torr to <br /> of "e ttwat the proposed structure will be constructed inconipi <br /> ac2rf3 <br /> CITY 01 EVEFtETT . 3200 Cedar Street . Everett, WA 98201 • (425) 257-8810 • Fax(4 25) <br />
The URL can be used to link to this page
Your browser does not support the video tag.