CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS <br /> TABLE 1104.9 1104.13.1 Height.Handrail height,measured above stair <br /> REVOLVING DOOR SPEEDS tread nosings, shall be uniform, not less than 30 inches <br /> INSIDE DIAMETER POWER-DRIVEN-TYPE MANUAL-TYPE (762 nun)and not more than 42 inches(1067 mm). <br /> (feet-Inches) SPEED CONTROL SPEED CONTROL <br /> (rpm) (rpm) 1104.14 Slope of ramps. Ramp runs utilized as part of a <br /> 6-6 11 12 means of egress shall have a running slope not steeper than <br /> 7-0 10 11 one unit vertical in 10 units horizontal (10-percent slope). <br /> 7-6 9 11 The slope of other ramps shall not be steeper than one unit <br /> vertical in eight units horizontal(12.5-percent slope). <br /> 8-0 9 10 1104.15 Width of ramps. Existing ramps are permitted to <br /> 8-6 8 9 have a minimum width of 30 inches (762 mm) but not less <br /> 9-0 8 9 than the width required for the number of occupants served as <br /> 9-6 7 8 determined by Section 1005.1.In Group I-2,ramps serving as <br /> a means of egress and used for the movement of patients in <br /> 16-0 A, 7 8 beds shall comply with Section 1105.5.4. <br /> For SI: 1 inch=25.4 mm,1 foot=304.8 mm. 1104.16 Fire escape stairways. Fire escape stairways shall <br /> 1104.9.1 Egress component.A revolving door used as a comply with Sections 1104.16.1 through 1104.16.7. <br /> component of a means of egress shall comply with Section 1104.16.1 Existing means of egress. Fire escape stair- <br /> 1104.9 and all of the following conditions: ways shall be permitted in existing buildings but shall not ' <br /> 1. Revolving doors shall not be given credit for more constitute more than 50 percent of the required exit capac- <br /> than 50 percent of the required egress capacity. ity. <br /> i <br /> 2. Each revolving door shall be credited with not more 1104.16.2 Protection of openings. Openings within 10 <br /> than a 50-person capacity. feet(3048 mm)of fire escape stairways shall be protected <br /> 3. Revolving doors shall be capable of being collapsed by opening protectives having•a minimum 3/4-hour fire <br /> when a force of not more than 130 pounds(578 N)is protection rating. <br /> applied within 3 inches(76 mm)of the outer edge of Exception: In buildings equipped throughout with an <br /> a wing. approved automatic sprinkler system, opening protec- <br /> 1104.10 Stair dimensions for existing stairways. Existing tion is not required. ( <br /> stairways in buildings shall be permitted to remain if the rise 1104.16.3 Dimensions. Fire escape stairways shall meet <br /> does not exceed 81/4 inches (210 mm) and the run is not less the minimum width, capacity,riser height and tread depth <br /> I than 9 inches(229 mm).Existing stairways can be rebuilt.Exception: Other stairways approved by theas specified in Section 1104.10. <br /> fire code <br /> 1104.16.4 Access.Access to a fire escape stairway from a <br /> official. corridor shall not be through an intervening room.Access <br /> 1104.10.1 Dimensions for replacement stairways. The to a fire escape stairway shall be from a door or window <br /> replacement of an existing stairway in a structure shall not meeting the criteria of Section 1005.1. Access to a fire <br /> be required to comply with the new stairway requirements escape stairway shall be directly to a balcony, landing or <br /> of Section 1009 where the existing space and construction platform.These shall not be higher than the floor or win- <br /> will not allow a reduction in pitch or slope. dow sill level and not lower than 8 inches(203 mm)below ?, <br /> the floor level or 18 inches (457 mm) below the window <br /> 1104.11 Winders. Existing winders shall be allowed to sill. <br /> remain in use if they have a minimum tread depth of 6 inches 1104.16.5 Materials and strength. Components of fire <br /> (152 mm)and a minimum tread depth of 9 inches(229 mm) escape stairways shall be constructed of noncombustible <br /> at a point 12 inches(305 mm)from the narrowest edge. <br /> materials. Fire escape stairways and balconies shall sup- <br /> 11104.12 Curved stairways.Existing curved stairways shall port the dead load plus a live load of not less than 100 <br /> be allowed to continue in use, provided the minimum depth pounds per square foot (4.78 kN/m2). Fire escape stair- ' <br /> of tread is 10 inches (254 mm)and the smallest radius shall ways and balconies shall be provided with a top and inter- <br /> be not less than twice the width of the stairway. mediate handrail on each side. 1 <br /> 1104.13 Stairway.handrails.Stairways shall have handrails 1104.16.5.1 Examination. Fire escape stairways and <br /> on at least one side.Handrails shall be located so that all por- balconies shall be examined for structural adequacy <br /> tions of the stairway width required for egress capacity are and safety in accordance with Section 1104.16.5 by a <br /> within 44 inches(1118 mm)of a handrail. registered design professional or others acceptable to <br /> Exception: Aisle stairs provided with a center handrail the fire code official every 5 years,or as required by the <br /> are not required to have additional handrails. fire code official.An inspection report shall be submit- <br /> ted to the fare code official after such examination. I <br /> 206 2015 INTERNATIONAL FIRE CODE® <br />
The URL can be used to link to this page
Your browser does not support the video tag.