Laserfiche WebLink
ENVIRONMENTAL HEALTH DIVISION <br />�i. ,W,;a SNOJ HOIISH 3020 Rucker Avenue, Suite 104 <br />HEALTH Everett, WA98201-3900 <br />�1 DISTRICT 425.339.5250 FAX:425.339.5254 <br />Deal/Hard of Hearing: 425.339.5252 (TTY) <br />February 8, 2008 <br />kwl-cZS <br />Esther Foerderer <br />14605 9"' Place NE <br />Shoreline, WA 98155 <br />Subject: Proposed, CC Teriyaki @ 3201 Rucker Avenue, Everett <br />Dear Ms. Foerderer: <br />Your plans have been reviewed with the Rules and Rer<ulations of the State Board of Health, and with <br />the policies of the Snohomish Health District. With the addition ofthe following conditions, the plans <br />are approved. <br />1. The Health District operating permit application process must be completed prior to opening for <br />business. The permit categol" will be Rest:nn'ant: I ligh Itisl<, with scats. <br />2. 'file three-comparunent sink must be National Sanitation Foundation (NSF) or equivalent listed and <br />be freestanding with integral drain boards at the right side. A clean side dish table will be located at <br />the left side of the dishwasher. <br />3. An indirect waste drain is required as indicated in the Plumbing Information section of the plans. <br />4. A reduced pressure backflow prevention device is required at the end of the copper water pipe <br />serving the pop dispensing system prior to the carbonation device. No copper pipe or other <br />potentially corrosive material is allowed after the reduced pressure backflow prevention device. <br />5. A vertical partition 16" high splash guard is required (as indicated on the plans) between the two <br />preparation sinks. A splash g;:ard is not required on the right side of the neat preparation sink, # 1 I. <br />6. Water heaters must be of sufficient size to provide hot water to dishwasher and/or scullery sinks and <br />at the same time provide hot water to all hand wash sinks. <br />Hot water must be available to all hand wash sinks within 15 seconds. The hot water for the facility <br />must not be used, at any plumbing fixture, for a minimum of 6 hours prior to the preoperational <br />inspection. This is required so that proper testing of the 15-second time requirement f'or hot water <br />availability can be completed. <br />8. All food service equipment, both new and used, must be listed by the National Sanitation <br />Foundation (NSF) or equivalent for its intended use. Used and new refrigeration must be capable of <br />holding potentially hazardous food at 41°F or below. <br />9. Extra wall protection is required on walls behind all sinks, including restroont hand wash sinks, and <br />food preparation counters and tables. A 16-inch high backsplash of plastic laminate. fiberglass - <br />reinforced plastic or equal is acceptable. A backsplash higher than 16 inches is required on the wall <br />behind counter top equipment taller than 16 inches. Floor to ceiling protection is required on the wall <br />behind dishwashers. Wall protection behind mop sinks must cover the entire splash zone. Plastic <br />coated hardboard is nc+ acceptable. <br />10. All floors in the kitchen, food preparation, food service, food storage, and dishwashing areas must be <br />surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, scams, saw cuts <br />and the like in concrete floors in all areas, including customer seating areas, must be filled and <br />scaled so as to provide a smooth and cleanable surface. <br />11. The ceiling above the food preparation areas must be nonperforated, nonabsorbent, smooth and <br />easily cleanable. <br />C//P <br />