My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3201 RUCKER AVE CC TERIYAKI 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
3201
>
CC TERIYAKI
>
3201 RUCKER AVE CC TERIYAKI 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2022 11:31:26 AM
Creation date
9/26/2019 10:05:22 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3201
Tenant Name
CC TERIYAKI
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
116
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Dr. Reichlin <br />October 14. 2004 <br />Page 2 <br />7i 4. If the expanded area has an occupant load of more than 50, the stairs leading up to the <br />existing lounge will be required to be widened to a mininmm of 44" and be provided with <br />a handrail on each side of the stairs. Sections 1009.1 & 1009.11 <br />C9The windows adjacent to the new entry doors should be shown as safety glazing. Section <br />2406.3 <br />�J Insulation should be shown for the new roof section (indicate whether the heat is a type <br />of electric resistance or other). WSEC Table 13-1 <br />Attic ventilation should be shown for both the new and revised roof areas. If the roof <br />insulation is installed other than on top of the roof sheathing, attic ventilation should be <br />provided at a ratio of Isf -tf ventilation to 150 sf of attic space. Section 1203.2 <br />8.) Weather protection should be shown for the new glu-lam beam (see detail on Sheet 6). <br />— Section 1403.2 <br />0 It should be detailed how the new and revised roof areas will drain. Section 1503.4 <br />—1 10. All exit doors should be shown with panic hardware. 1008. L9 <br />S 11. Exit signs should be shown at each exit door. The signs should be hardwired and <br />provided with a battery backup. Section 10 11. 1 <br />(} 12. Tactile exit signs should be shown at each exit door. They must comply with the <br />requirements of ICC A117.1. Section 1011.3 <br />T 13. Maximum occupant load signs should be shown in rooms larger than 750 square feet. <br />The number of persons should be stated on the plans. Section 1004.3 <br />Please prepare a response letter showing where each item in this correction letter is addressed on <br />the plan set. <br />Upon resubmission of the drawings, your application will be given priority and plan review will <br />recommence. <br />All required submittals must be of sufficient detail and contain sufficient information to ensure <br />that the proposed structure will be constructed in compliance with all adopted codes. <br />Sincerely, <br />Tony R. Lee <br />Plans Examiner <br />(0) <br />
The URL can be used to link to this page
Your browser does not support the video tag.