My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3723 RUCKER AVE Geotech Report 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
3723
>
Geotech Report
>
3723 RUCKER AVE Geotech Report 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:41:29 AM
Creation date
9/26/2019 2:38:20 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3723
Address Document Type
Geotech Report
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br />::;, , ,,;; ,: <br />— : ,.�.�:: <br />� � , ��.. <br />e <br />,� <br />TE�tRA ASSOCIATES, Inc. <br />Geotechnical Consultants <br />Mr. Stan Sales <br />Norvestco <br />301 - 116th Avenue S.E., Suite 120 <br />Bellevue, WA. 98004 <br />Subject : Geotechnicel Engineering Study <br />Proposed Hoagy's Corner Building <br />Rucker Avenue end 38th Street <br />Everett, Washing[on <br />Dear Mr. Sales: <br />November 4, 1985 <br />Project No. T-233 <br />�[�C�[���'��;� <br />CITY Gi L`�r�r-�T <br />�^SD; Ci1Q11 �-� ���� <br />As requested, ve have conducted a geotechnical engineering study for the <br />subject project. The purpose of our study was to explore the subsurface soil <br />conditions at the property in order to provide recommendations for site <br />preparation, foundetion design end construction for this project. The scope <br />of our study included test ptts, l.aboratory tests, and geotechnical <br />engineering analyses. This report presen[s the findings and the results of <br />our studies, alo,ig wir.li supporting field and laboratory test data. <br />SUrAtARY OF FINDINGS <br />Our study indicates that the proposed building has been Eil:ed in the past by <br />up to 14 feet or more of silty send fill containing some debris which is <br />presently in a loose condition. Underlying the fills is an old topsoil/fill <br />horizon with a thickness ranging from 1.0 to 1.5 feet. Native soils <br />underlying the fill and old [opsoil consist of relatively firm; clean to <br />silty sands to the depths explored. <br />The loose fill soils underlying [he building area will not provide adequate <br />support for conven[ional spread foundations for the proposed building. In <br />addition, an existing rockery nlong the north and east sides of the site may <br />be subjected to excessive pressures by shallow building foundations. To <br />allow for these existing conditions the following foundation cri.teria are <br />considered appropriate. <br />1. Foundations for the building should be extended down to a level <br />below that of the base of the rockery. <br />2. The existtng fills should be removed to a minimum dep[h of two feet <br />beloa found�tion bottoms and replaced by structurel fills. In slab <br />and pavement arees, the depth of overexcavation should be at least <br />12 inches. <br />1301 i N.E. BSth Street • KtrKiana, wasnmgcon yown -�������. i���� �-•---�- <br />Mailing Address: P.O. Box 3338 • Redmond, Washington 98073 <br />
The URL can be used to link to this page
Your browser does not support the video tag.