Plans for such system shall be submitted to the Fire Marshal for review and approval prior <br />to installation. Submittal shall include cut sheets of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department inspector, shall be performed, along <br />with a certificate of completion, prior to final acceptance of the system. <br />Fire alarm systems shall be installed according to NFPA Standard 72. Installation of fire <br />alarm components, including basic wiring, may not commence before plans are <br />approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br />professionally rendered, in sufficient detail, and must be internally consistent. Riser <br />diagrams must match installation plans and load calculations. Components must be listed <br />and approved for use together. Changes to plans must include new drawings and <br />calculations and must be approved by the Fire Department Plan Reviewer prior to <br />installation. Fire alarm installation is subject to field inspection by a Fire Department <br />Inspector. An approved set of plans and the Engineering & Public Services Department <br />electrical permit must be present for any installation inspection. <br />Fire alarm systems shall be installed under permit of the City of Everett Engineering & <br />Public Services Department. Electrical inspections and approval are required prior to <br />calling for acceptance tests. For permit information call (425) 257-8810. <br />The absence of working phone lines for the alarm system will be cause for <br />postponing fire department inspection and testing and shall result in denial of <br />occupancy. <br />10. Construction and demolition of buildings shall be in compliance with the provisions of the <br />2006 International Fire Code, Chapter 14. <br />11. Permits are required from the Fire Department for removal and installation of <br />underground fuel tanks. <br />12. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or <br />closets with standard man door access. Locations shall be approved by the Fire Marshal's <br />Office. <br />13. Trash Collection - Dumpsters over 1.5 cubic yards capacity shall be located a minimum of <br />5 feet from the building (IFC 304.3.3, 2006 Edition). <br />14. Fire flow for this site is an issue that must be resolved; 2000 gpm is the minimum <br />requirement with a residual pressure of 20 psi at the hydrant. The hydrant at 45th and <br />Rucker flows 236 gpm, and the hydrant at the 4500 block of Evergreen Way (west side) <br />flows 1208 gpm; because of traffic density at this location EFD cannot lay a supply line <br />across Evergreen Way. A minimum of 2 hydrants that flew at least 1000 gpm or one <br />hydrant that flows at least 2000 gpm is required. <br />GENERAL INFORMATION <br />Puget Sound Energy is the natural gas provider in this area. To initiate new service <br />orders, please contact Marilyn Davis Wesllund at (425) 356-7512 at least 90 days prior to <br />the required in-service date. <br />U// <br />