My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4418 RUCKER AVE MEDICAL BLDG 2018-01-02 MF Import
>
Address Records
>
RUCKER AVE
>
4418
>
MEDICAL BLDG
>
4418 RUCKER AVE MEDICAL BLDG 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2022 1:29:52 PM
Creation date
9/30/2019 2:04:11 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
4418
Tenant Name
MEDICAL BLDG
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
167
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Plans for such system shall be submitted to the Fire Marshal for review and approval prior <br />to installation. Submittal shall include cut sheets of all equipment intended for use. <br />Appropriate trip tests, witnessed by a Fire Department inspector, shall be performed, along <br />with a certificate of completion, prior to final acceptance of the system. <br />Fire alarm systems shall be installed according to NFPA Standard 72. Installation of fire <br />alarm components, including basic wiring, may not commence before plans are <br />approved by the Fire Department Plan Reviewer. Fire alarm drawings must be <br />professionally rendered, in sufficient detail, and must be internally consistent. Riser <br />diagrams must match installation plans and load calculations. Components must be listed <br />and approved for use together. Changes to plans must include new drawings and <br />calculations and must be approved by the Fire Department Plan Reviewer prior to <br />installation. Fire alarm installation is subject to field inspection by a Fire Department <br />Inspector. An approved set of plans and the Engineering & Public Services Department <br />electrical permit must be present for any installation inspection. <br />Fire alarm systems shall be installed under permit of the City of Everett Engineering & <br />Public Services Department. Electrical inspections and approval are required prior to <br />calling for acceptance tests. For permit information call (425) 257-8810. <br />The absence of working phone lines for the alarm system will be cause for <br />postponing fire department inspection and testing and shall result in denial of <br />occupancy. <br />10. Construction and demolition of buildings shall be in compliance with the provisions of the <br />2006 International Fire Code, Chapter 14. <br />11. Permits are required from the Fire Department for removal and installation of <br />underground fuel tanks. <br />12. All fire alarm control panels (FACP) and sprinkler valves shall be in heated rooms or <br />closets with standard man door access. Locations shall be approved by the Fire Marshal's <br />Office. <br />13. Trash Collection - Dumpsters over 1.5 cubic yards capacity shall be located a minimum of <br />5 feet from the building (IFC 304.3.3, 2006 Edition). <br />14. Fire flow for this site is an issue that must be resolved; 2000 gpm is the minimum <br />requirement with a residual pressure of 20 psi at the hydrant. The hydrant at 45th and <br />Rucker flows 236 gpm, and the hydrant at the 4500 block of Evergreen Way (west side) <br />flows 1208 gpm; because of traffic density at this location EFD cannot lay a supply line <br />across Evergreen Way. A minimum of 2 hydrants that flew at least 1000 gpm or one <br />hydrant that flows at least 2000 gpm is required. <br />GENERAL INFORMATION <br />Puget Sound Energy is the natural gas provider in this area. To initiate new service <br />orders, please contact Marilyn Davis Wesllund at (425) 356-7512 at least 90 days prior to <br />the required in-service date. <br />U// <br />
The URL can be used to link to this page
Your browser does not support the video tag.