G. Ncw stair runs havc been added to the existing second floor on the east and west side of the new <br />business offices. "I'he following information should be included on the plans for each ncw stair: <br />• 1'he width of the stair (44 inches unlcss the occupancy is less than Sfl), per IBC sectiun 1009.1. <br />�• Iiandrails on Uoth sidcs, per IBC section 1009.10. <br />✓• Ilandrails should bc shown on thc drawings to cxtend bcyond thc Vc.:ds, per IBC scction ] 012.5. <br />-• The stairs should be dimensioned to indicate the minimum tread width of i l inches (in plan view) <br />and the maximum riscr height of seven inches (in section), per IBC section 10093. <br />�7. Plcasc indicate all cxisting and new cgress illumination, exit signage and tactile exit signs on the <br />drawings, ta mcet the requircments of IBC scctions 1006 and I011. <br />Accessibility <br />I. T'he cicar width of tLc elevator lobby is requircd to be fivc feet, per IBC Al 17.1 section 4042.5. <br />2. The pro61e of the stair handrails should be shown as `graspable' on the dra�vings, per IE3C Sections <br />]009.11.1, 1009.11.3 and ICC/ANSI 505.7. <br />3. The elcvation of door type I indicates a vision litc, which should be located so that t1�c bottom panel is a <br />maximum height of 43 inchcs above thc floor, or a minimum height of GG inches above the flaar, per <br />1BC Al 17.1 section 404.7..10. <br />Upon submission of rivo insert sets of revised drawings retlecting the correctior.s requested, your application <br />will be processed. Applicable codes include the 200G Intcmational Building Code (IRC), the 200G International <br />Fire Code (IPC), the 1.00G Intemational Mcchanical Code QMC), the 200G Washington State Energy Code <br />(WSEC), the 200G Washington State Ventilation and Indoor Air Quality Code �VIAQ), thc 2003 Accessible and <br />Usablc Buildings and Pacilitics Al 17.1-2003 (ICGANSI) and thc City of Evcrett Municipal Code, including <br />Chapter 1 G.7G, Automatic Pire Detection and Pire Suppression Systcros. All codes rcferenced, as adopted by tl�e <br />City of Evcrctt, should includc current revisions by thc Statc of Washington. Thesc comments address building <br />issues only. Revisions or additions may bc reqaircd by othcr departments (such as Utilities, Planning or Fire). <br />Atl required submittals must be of sufficient detail and information to ensure that the proposed structure will be <br />constructed in compliance with all adoptcd codes. You can reach me directly to discuss this letter by e-mail at <br />mhalcy�>ci.cacrctt.�va.us or by pl�onc at 425-257-3513. <br />NCAl2l3 <br />Cc: Mr. Al'cx ChcrUa, Odysscy Consh-uction <br />J <br />