Laserfiche WebLink
October G, 2008 <br />:NG/NEER/NG / �UBL/C 5E/u//CE5 .OEPARTA!_FNT <br />Ms. Ruth Gonzales <br />Gonzales Dcsign Partners <br />P.O. Box 97 <br />Arlington, Washington 98223 <br />Project: Daycare and meuanine offices <br />Job Address: 830 SE �verett Mall Way <br />Plan Review No: BO801-047 <br />Dcar Ms. Gonzalcs, <br />In response to your application for building construction pertnit, a permit cannot be is:aued until the following <br />issucs are resolved. Please provide a response Ietter for cach of thc following items ta identify a sheet and detail <br />numbcr to reference for the corcection listed. Por clarification, please "cloud" drawing revisions in response to <br />this lettcr. Two complete sets are requircd for permit submittal. <br />Building Permit Plan Revicw: <br />Regurding items 1 of'!he prerious let[er dater! Ju(y 9, 2008: <br />1. Thc new area added to thc existing mezzaninc should be calculated on the code analysis. The existing <br />building total squarc foot arca of first floor and mezzanine was 35, )71 square feet, per the ceRificatc of <br />occupancy datcd 1993. The new mezzanine area would increase thc overall squarc footage of the <br />building. If it is nut the intent to includc the mezzanine work at this time undr.r this permit, please do <br />not include it on thc drawings. <br />Regnrdrng ilern 3 ojdie prevro�cs letter: <br />2. ArchitecWrai sections indica:ing ceiling heights, tloor heights, dctails of construction, fire-resistance <br />rating, matcrials and sizcs arc requi��d for thc slage, in the sanctuary, for the ncw second floor <br />mczzaninc arca, for the sound Uootli, and for the elevator. If the stage, elevator, mczzanine or sound <br />booth are not included in tl�is submittal for building permit, please do not include them on the drawings. <br />Regm•ding item 6 aj0�e previous leller: <br />3. The occupancy calculations for daycare require specific ages and number of children for each daycarc <br />room. The occupancy ty��c educalional (G) only applies to daycare when each child-care room has an <br />exit door directly to the ou!s�de, per IBC 308.5.2, when therc are six or more children less than 2.5 years <br />of age, and the occupancy of the room for daycarc is ten or less. Please reference the specific detail and <br />shcct far this infomiation in your response letter. <br />4. If classroom 10G is for children that are in daycare, the maximum occupancy of the room is ten, and <br />each separate classroom will requirc an exit direcdy to the exterior, per I13C table ]015.1. <br />5. If classroom 11 l is for cliiidren that are in daycare, the maaimum occupancy of the room is ten, and <br />each separate classroom will require an exit directly to the exterior, per IBC table 1015.1. <br />CITY OF EVERETf • 3200 Cedar Street • Everett, WA 98201 •(425) 257-880C� • Fax (425) 257-8856 �� <br />S\NIIa1.���1brJ.U0Xn1.UD F10 Sc f..<an �Iill N'ay:nJ vcbminvl dnc <br />