My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
830 SE EVERETT MALL WAY HARVEST CHRISTIAN CENTER 2018-01-01 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
830
>
HARVEST CHRISTIAN CENTER
>
830 SE EVERETT MALL WAY HARVEST CHRISTIAN CENTER 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/7/2019 3:08:17 PM
Creation date
10/7/2019 2:52:20 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
830
Tenant Name
HARVEST CHRISTIAN CENTER
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
206
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
G. If playground I1: is for children that are in daycare, the maximum occupancy of the room is ten, per <br />IBC tablc ]015.1. <br />7. Nursery room 114 and baby room 115 require a wall to separate them into areas not to exceed 35 squarc <br />feel (35 square Y'oot per person times 10 maximum occupants) per IBC tables 1015. ] and 1004.1.1. <br />Regarding iteni 9 of the previo«s letter: <br />8. If the new area of the mezzanine in the nor[hwest corner of the building exceeds 3000 squarc feet, then <br />an elevator will bc rcquired per IBC section 1104.4, to provide an accessible route per IBC sections <br />1109.G �nd 30013, including the minimum interior elevator cab dittiensions of ICC A117.1 figure <br />407.4.1. <br />Regarding ite�u 10 of Ihe prei�ious letter: <br />9. Structural drawings should indicate dctails of the structural support assembly, per IBC 1G03.1. This <br />dctailing should include material size, thickness, dimensioning, and connections. <br />10. All structural drawings and calculations should be stamped and wet-stamped by a Washington State <br />professional engincer to vcrify that the new structures will resist required wind, gravity and scismic <br />loading. Washington Statr. regulalcs thc licensing for an enginecr whcre soil-structure interaction, <br />connections, loading and forces, load and svess analysis design are rcyuircd for building permit, per <br />RCW 18.43.070 and WAC 19C-23-020. <br />Regnrdiiig ireni II oj0�e prevrnus letter: <br />1 I. Thc R-valuc of the insulation wherc thc exteriar wall exposed durins construction should be shown on <br />tl�c drawings, per WSL'C 1013.2.4. Please reference the specific detail and shcet for this information in <br />your response letter. <br />12. The ncw daycarc facilities will require water closets and lavatories per IIIC table 2902. I. Plcase <br />indicatc that Aie existing plumbing facilitics are sufficient 1'or this additional load. <br />13. Drinking fountains arc requircd per II3C scction 2903.4, and should be shown on the drawings, per ICC <br />AI 17.1 section G02. If the drinking fountain is primarily for children's use, this should be indicated on <br />the drawings. <br />14. Bath 116 is rcquired to have minimum 5 fcet clear behvicen the sink and thc wall, where lhe water closet <br />is located, per ICC A 117.1 section G043.2 for clearancc at the water closet. <br />Applicable codes includc the 2006 Intcmalional IIuilding Code (IIIC), thc 200G International Mechanical Code <br />(IMC), the 200G International Pire Code (IGC), the 200G Washington Statc �ncrgy Code (WSEC), thc <br />Washington Siatc Vcntilation and Indoor Air Quality Code (WSVIAQ) 2006, and dic 2003 AccessiUlc and <br />Usablc Buildings and Pacilities A117.1-2003 (ICC/ANSI). All codes referenced, as adopted by thc City of <br />�verett, should include current revisions Uy the Statc of Washington. Thesc commcnts address building issucs <br />only. Revisions or additions may bc required by other departments (such as Utililics, Planning or Fire). Upon <br />submission of two complete sets of die revised drawings and calculations, your application will be given priority <br />and plan review will bcgin. All requircd submittals must be of sufGcicnt dctail and information to ensure that <br />the proposcd structurc will Ue constnicted in compliancc witl� all adopted codes. You can rcach me directly to <br />discuss this lctter by e-mail at mlialey@ci.everctt.wa.us or by phone at 425-257-5813. <br />I Plans �xamincr Cc: Assistant Building Otficial Tony Lce, COE <br />� <br />I��Ltip I�w] S)n Sc Gracn Alnll \Vay Intl mMiinol Ax <br />
The URL can be used to link to this page
Your browser does not support the video tag.