Laserfiche WebLink
�cbruary 10, 2009 <br />:NGi1YEER/NG / PUBL/C SEL�f�/CE5 OEPARTiNE/M'T <br />Ms. Ruth Gonzales <br />Gonzales Design Partners <br />P.O. Box 97 <br />Arlington, Washington 98223 <br />Project: Baptistry and Sound Booth for Center Religious Room <br />Job Address: 830 SG Everett Mall Way <br />PlanRevicwNo: B0901-01S <br />Dcar Ruth, <br />Thank you for your application for building construction pemtit. The ptans have been examined and a permit <br />cannot be issued until the following issues are resolved. Please provide revised drawings and a response lctter <br />that statcs how cach itcm has bccn resolved on the drawings. For additional clarification, please cloud and <br />identify revisions lo the drawings for permit. Please let me know if I can assist to update both scts of drawings <br />with thc rcviscd shcets. <br />Gencral <br />l. 1'o rcclassify this building from the 1988 Uniform Building Code to the 200G International Building <br />Codc, the code data summary should include the following: <br />✓a. Ilcight oCthc building <br />` b. Idcntification of the floor levcls in the building: first and sccond <br />� c. Determination of scparation or u,.n-separation of the occupancy classifications <br />� d. Square footage per occupancy area and per t7oor <br />'�e. Occupant load per occupancy area and per 11oor, using the load factors in IBC table 1004.1.1 <br />�1: Squarc I'oot area of work under pemiit �Plcase notc: the projcct data rcfcrs to phase I for area <br />under improvcment, but the permit application refers to phase 2] <br />= g. Second floor to Ue unlocked for egress purposcs to ma�ntain common path oFegress travel <br />� h. 300 feet maximum exit acecss travcl distance to an exit door from second floor at any point; <br />250 feet maximum if the sanctuary balcony is uscd for assembly purposes. <br />2. It would bc hclpful to havc half size drawings oC the current first and sccond tloor to record thc building <br />design reclassification, with occupancy types (mid occupancy count totals by occupancy area) marked <br />on tl�e plans. Attached for reference are thc drawings as submitted in 1991. <br />i <br />/ 3. Is thc `sound booth' enclosed? Thc drawings reCerence a sound booth, but thcrc is no 6eoth enclosure <br />shown on cither the first or thc second fioor for sound equipmeut. Please clarify. <br />4. fhc baptistcry manufacturcr's catalog cut should bc submitted indicating total capacity, uincnsional <br />sizc and drainagc. <br />�The hcight of the baptislery above the stage should bc dimcnsioned on the drawings. <br />� <br />�A crass scction through the ramp or clearer markings on the plan should be submitted to clarify the <br />porlion of thc iloor that is slopcd, and detail the construction represented by doubie lines on the east side <br />oC the stagc. <br />� <br />l, ) <br />CITY OF EVERETT • 3200 Cedar Street • Everelt, WA 9Ei201 •(425) 257-8800 • Fax (425) 257-8856 �, <br />