My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1310 SE EVERETT MALL WAY Geotech Report 2022-10-25
>
Address Records
>
SE EVERETT MALL WAY
>
1310
>
Geotech Report
>
1310 SE EVERETT MALL WAY Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 11:48:34 AM
Creation date
10/14/2019 8:43:55 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1310
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
��,��� Irrforntation <br /> lI'��ToBuild On <br /> �•�•� <br /> September 15, 2011 <br /> Mr. John M. Keen <br /> Darden Restaurants, Inc. <br /> Design and Construction � �,�C�y—(TJC�� <br /> 1000 Darden Center Drive <br /> Orlando, Florida 32837 <br /> Subject: Geotechnical Engineering Services Report <br /> Proposed Olive Garden Restaurant <br /> Everett Mall <br /> Everett, Washington <br /> PSI Project No. 712480-1 <br /> Dear Mr. Keen: <br /> Professional Service Industries, Inc. (PSI) has completed a subsurface exploration program at the <br /> above referenced project site. The proposed restaurant is located in the northern parking lot of <br /> the Everett Mall which has an address of 1402 SE Everett Mall Way in Everett, Snohomish <br /> County, Washington as shown on the Vicinity Map, Figure 1. The subsurface exploration was <br /> conducted to provide information needed for recommendations for site preparation and foundation <br /> design and construction for the referenced restaurant. The services herein were completed in <br /> general accordance with "Technical Consulting Services Agreement" dated May 18, 1999 <br /> between Darden and PSI. The following report presents the results of the study, as weli as <br /> opinions and recommendations pertaining to the geotechnical aspects of the project. <br /> 1.0 PROJECT INFORMATION <br /> 1.1 Site Location and Proiect Description <br /> The Site Exploration Plan, Figure 2, shows the layout of the proposed restaurant. PSI has been <br /> provided with a site plan prepared by GHA Architecture/Development. <br /> PSI understands that the proposed Olive Garden restaurant will consist of a wood framed one- <br /> story building supported on conventional concrete foundations. The structure may have some <br /> exterior masonry, and there will be a concrete slab-on-grade. PSI anticipates that foundation <br /> loads will be approximately 1 to 3 kips per linear foot for strip footings, and that column loads will <br /> be as high as 50 to 75 kips. We understand that new pavements will not be constructed as part of <br /> this development. <br /> We expect that site grading will include cuts or fills of less than 2 feet. Please notify us if the <br /> design loads or site grading will be different from that assumed so that we can re-evaluate and <br /> modify our recommendations, if needed. <br /> The information presented in this section was used in the evaluation. Estimated loads and <br /> corresponding foundation sizes have a direct affect on the recommendations, including the type of <br /> foundation, the allowable bearing pressure, and the estimated settlement. In addition, estimated <br /> subgrade elevations and cut/fill depths also have a direct affect on the provided recommendations. <br /> Professional Service Industries,Inc..24113—56'�'Avenue West,Mountl�ilce"I'errace,WA 98043.Phone 425/248-2400•Fa�c 425/248-2401 <br /> Beg i n »»»»»»»»»»> <br />
The URL can be used to link to this page
Your browser does not support the video tag.