Laserfiche WebLink
NOTES: ROUTE FLEX CONDUIT <br /> A. INSTALL BATTERY ELIMINATOR TRANSFORMER(FURNISHED UNDER SECTION 08 7100).PROVIDE 120 VOLT THRU 2"COPE IN BEAM <br /> BRANCH CIRCUIT TO TRANSFORMER AND LOW VOLTAGE BATTERY ELIMINATOR. � ,�� REFER TO 7A/S531 <br /> � o �, � � � <br /> B. ROUTE CONDUCTORS TO LOW VOLTAGE TERMINALS OF BATTERY ELIMINATOR THROUGH CONCEALED 1/2"C \����� %,' \`� <br /> EXTERIOR .� `�\ �%S'fUB CONDUIT OUT OF EXTERIOR ROUTE FLEX CONDUIT(S) PROVIDE METALLIC I <br /> C. ROUTE CONDUCTORS TO DETEX HARDWARE THROUGH RACEWAY. PROVIDE FINAL CONNECTION TO DETEX WALL ��o �,�'� WALL. PROVIDE BUSIN�� DOWN VERTICAL MULLION NEMA1 24°X24"X6"DEEP �—� DRILL&INSTALL GROMMET FOR J-BOX i <br /> HARDWARE. � , � � <br /> ` �� % ' � � � % �� �� ROUTING OF CONDUIT AND WIRE FROM LOCATED ; <br /> _ \��� 5,, �\\ LOCATED IN CENTER OF PULL BOX WITH SCREW , � '� TRENCHING FOR FLOORBOX TO ABOVE ABOVE CEILING - <br /> �� , BRANCH CIRCUIT WIRING DOORS. REFER TO STORE COVER � <br /> D. PAINT ALL EXPOSED RACEWAY TO MATCH SURFACE ON WHICH IT IS MOUNTED `��o o��' �� � FRONT MANUFACTUERS � 3/4"CONDUIT STUBBED FROM ACCESSIBLE CEILING. 1"MAX HOLE SIZE. <br /> � PROVIDE BUSHWG I DETAIL 1/6.05 EAS MODU!E PULL BOX TO BOTTOM SIDE OF � Q � <br /> i <br /> BRANCH CIRCUIT WIRING � INSTALLED IN PULL BOX JOIST FOR DATA CABLE <br /> ► 12 VAC,25A TRANSFORMER BY EAS VENDOR CONNECTION CEILING � i <br /> 1000 NICOLLEI� N9ALL <br /> � 12 VAC,25 VA CEILWG ROUTE FLEX CONDUIT(S) MOUNT PULL BOX 2'-0° — � PROVIDE QUADRUPLEX i MINNEAPOLIS MN 55403 <br /> TRANSFORMER HORIZONTAL REFER TO STORE <br /> CEILING FRONT MANUFACTURERS DETAILS ABOVE ACCESSIBLE `�' RECEPTACLE INSIDE PULL BOX, i ' <br /> LOW VOLTAGE WIRING IN CONDUIT 1/5.03 AND 2/5.03 CEILING MOUNT RECEPTACLE IN THE i <br /> _ INTERIOR WALL � UPPER RIGHT HAND CORNER OF i <br /> � � � CONCEAL IN WALL FURRING. LAY-IN CEILWG THE PULL BOX.VOICE/DATA <br /> z �� J-BOX PRE-INSTALLED IN DOOR � <br /> J CEILING U.N.O. HEADER FOR SECURITY CONTACT CONTRACTOR TO PROVIDE DATA i CONCEAL CONDUIT AND <br /> � w SECURITY DEVICES(TYP) OUTLET BELOW RECEPTACLE. i WIRE fNSIDE OF COLUMN <br /> SECURITY CONTACT CONDUIT REFER TO i <br /> � o � � FLUSH MOUNTED J-BOX FOR � <br /> FLUSH MOUNT J-BOX FOR BATTERY BATTERY ELIMINATOR(BE-96191) i <br /> i ELIMINATOR(8E-961-1) PROVIDE 1 1/4"CONDUIT i <br /> - ROUTE CONDUIT INTO HOLLOW DOOR PROVIDE 3!8"ARMORED CABLE BETWEEN PULL BOX AND J-BOX � <br /> -'� " _ METAL DOOR FRAME 6"FROM HEADER FROM BATTERY ELIMINATOR J-BOX EAS MOUNTED AT BASE OF WALL � DRILL&INSTALL GROMMET FOR <br /> C9 SURFACE RACEWAY,WIREMOLD DOOR JAMB, LATCH SIDE OF TO SURFACE MOUNTED RACEWAY PEDESTALS i ROUTING OF CONDUIT AND WIRE FROM <br /> V500 SERIES OR EQUIVALENT W/90° DOOR � MOUNTED ON DOOR PROVIDED BY i TRENCHING FOR FLOORBOX TO ABOVE <br /> FLAT ELBOW CORNER.RUN AS SECURITY ` EAS VENDOR i ACCESSIBLE CEILING. 1" MAX HOLE SIZE. .�'� 1°�.�.a�� �����'� �I``� � � � � �. ��. � <br /> CLOSE TO HINGES AS POSSIBLE. SECURI EVICES AND DOOR PROVIDE GROMMET WHEN CCTV CAMERA � <br /> CONNECT TO J-BOX W/WIREMOLD CABL q� ARMORED CABLE EXIT WALL CAVITY EAS SAWCUT PROVIDE J-BOX AT BASE OF i <br /> CONTACT, BY GENERAL WALLABOVE SAWCUT.VERIFY —I <br /> � V500 SERIES 18"LONG FLEXIBLE REFER TO i +— - - - <br /> SECTION. DETAIL 2/E982 PhOVIDE 6"ARMORED CABLE CONTRACTOR LOCATION WITH GENERP,L i i <br /> SERVICE LOOP CONTRACTOR. i i <br /> DOOR � DOOR OPERATOR � FLOOR www.ctagroup.com <br /> FRAME VERTICAL MOUNTED RACEWAY FLOOR <br /> � EN���GENCY EXIT DOOR DETEX 2 SECTION INTERIOR DOOI� SECUR�TY DEV�CE 3 �ECTIO� EX�Ei�IOR DC�O� SECUReTY DEViCE 4 CONDUIT STOREFRON� DETA(L 5 E�4S POWEI� & SYSTEMS DETA6L 6 C��CEAL CONDUIT AND WIRE {N COLUMf� DETAIL <br /> E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE <br /> 10 <br /> CABLE(S)ARE ALLOWED TO E511 <br /> BE SUPPORTED FROM TOP JOIST SPAN. <br /> CHORD OF JOIST(DO NOT <br /> EXCEED 100 LBS PER —��— _ SECURE CHANNEL AT EACH i <br /> POINT LOAD AT TOP ��� , � � END TO TOP CHORD OF BAR <br /> JOIST AT PANEL POINT WITH <br /> CHORD OF JOIST) ���\�� �;' `�� '� MINIMUM 4"CLEAR <br /> `��o ��' `� FROM BOTTOM OF CHANNEL CLIP&SET SCREW. <br /> �, �� TYP I CAL. <br /> STEEL COLUMN (10)1" CONDUIT OR 1"DIA � \�� � ROOF DECK TO TOP <br /> TYPE MC CABLES ��`\� OF CABLES <br /> r <br /> REFER TO SHEET E701 � ) � ) / \\ <br /> CONDUIT S &CABLE S ARE ���` %� �� '�� <br /> FOR WIRING DIAGRAM ALLOWED TO BE ATTACHED `���� �;' `�� �,;'' o — ° <br /> �— DO NOT SUPPORT CONDUIT <br /> TO BOTTOM CHORD OF JOIST — --rROM WEB OF JOIST <br /> TEMPERATURE/ (REFER TO LOAD REQUIREMENTS) � �! <br /> � HUMIDITY SENSOR BAR JOIST � CHANNEL PIPE STRAP SIZE AS �a�� B�60. Descrip�ion <br /> (2)BUNDLES OF 50 � 1-1/2"X 1-1/2"X 12 GA STEEL REQUIRED O2/O6/"I H PERMiT ISSUE <br /> LOW VOLTAGE CABLES <br /> � CHANNEL WITH 1/2"HOLES <br /> GENERAL NOTES: j ON 1-1/2"CENTERS O O <br /> A. MAXIMUM OF 100 LBS TOTAL LOAD OF EQUIPMENT IS ALLOWED TO BE ATTACHED TO EACH JOIST SPAN BOTTOM o 0 <br /> 1/4"HOLE AND � CHORD. WHEN LOAD REQUIREMENTS LISTED BELOW ARE ATTAINED,ATTACH ADDITIONAL CONDUIT(S)AND MAXIMUM OF 1"CONDUIT(S)ARE <br /> GROMMET CABLE(S)TO JOIST TOP CHORD. ALLOWED TO BE ATTACHED TO <br /> ATTACH THREADED RODS TO JOIST BOTTOM CHORD. REFER TO <br /> B. LOAD REQUIREMENTS: CHANNEL W/SELF HOLDING DETAIL 9/E511 FOR <br /> MAXIMUM OF(10) 1"CONDUITS OR MAXIMUM OF(10) 1"DIA TYPE MC CABLES ARE ALLOWED TO BE ATTACHED TO CHANNEL NUTS AND DOUBLE CONDUIT/CABLE JOIST BOTTOM <br /> EACH JOIST SPAN BOTTOM CHORD AND MAXIMUM OF(2) BUNDLES OF LOW VOLTAGE CABLES ARE ALLOWED TO BE NUTS AND WASHERS CHORD LOAD REQUIREMENTS. <br /> ATTACHED TO EACH JOIST SPAN BOTTOM CHORD AND MAXIMUM OF(20)SINGLE LOW VOLTAGE CABLES ARE <br /> ALLOWED TO BE ATTACHED TO EACH JOIST SPAN BOTTOM CHORD � � <br /> C. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. BAR JOIST NOTES: <br /> CONDUITS A. MOUNT ASSEMBLY AS HIGH AS POSSIBLE, BUT MAINTAIN MIN 4"BELOW ROOF DECK. DO NOT INTERFERE W/ <br /> D. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE.CBLE SHALL BE INSTALLED IN A MANNER THAT NORMAL WORK OF OTHER TRADES, BLOCK AIR DIST, FIRE PROTECTION OUTLETS OR LIGHT FITURES. <br /> BUILDING MOVEMENT WILL NOT DAMAGE CABLES. <br /> B. DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST <br /> �C��UN�i� TEMP�RA�URE / �UMIDETY <br /> � SENSO� Q�TAIL 8 QVERHEAD COILING DC30�. 9 L0� VOLTAGE SUPPQF�T REQU��EMENTS �o �O�DUIT HANGER DETA6L PLAN V��W 11 CO�DU�� HANGER SECTiO� <br /> E511 SCALE: NOT TO SCALE E511 SCALE: 1/4"= 1'-0" <br /> E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE <br /> CABLE(S)ARE ALLOWED TO BE <br /> SECURE THREADED ROD WITH SUPPORTED FROM TOP <br /> SELF HOLDING CHANNEL NUT, �2 CHORD OF JOIST(DO NOT <br /> SIZE AS REQUIRED E511 EXCEED 100 LBS PER POINT JOIST SPAN CABLE(S)ARE ALLOWED TO BE <br /> � _ OFJ OI�STT(DO NO MEXCEEDORD <br /> LOAD AT TOP CHORD OF <br /> JOIST) 100 LBS PER POINT LOAD AT <br /> DO NOT SUPPORT CABLES �� o, � ,� TOP CHORD OF JOIST) <br /> CONTINUOUS THREADED ROD i i i� FROM WEB OF JOIST ����`\� ��,� `\��\� �'�,' <br /> -3/8"f�MINIMUM, SIZE AS i i i i ���`� ��,� `� �'�,' DO NOT SUPPORT CABLES <br /> � REQUIRED SECURE CHANNEL AT EACH UP TO STRUCTURE — UP TO STRUCTURE � � �� `�� ' o %� FROM WEB OF JOIST <br /> DO NOT SUPPORT CONDUIT END TO TOP CHORD OF BAR � � �� ________— FIRE ALARM, INSTRUSION, `°�� o°'� <br /> i�i� FROM WEB OF JOIST JOIST AT PANEL POINT � � PAGING, EMS, COAX& ��° � \\ ��,' CABLE(S)ARE ALLOWED TO BE <br /> J-BOX WITH BLANK 1/2"LB � �� , �� ,, � SUPPORTED FROM BOTTOM <br /> W/CHANNEL CLIP AND SET CONTROL CABLES CAN BE � �� , � \� ,, , <br /> SCREW COVERPLATE � CHORD OF JOIST(REFER TO <br /> INSTALLED ON JOIST FLANGE � GENERAL NOTES <br /> DRILL 3!4"HOLE IN DRILL 3/4"HOLE IN OR TOP OF BOTTOM CHORD � <br /> � MAXIMUM OF 1"CONDUIT(S)ARE O O DO NOT SUPPORT CONDUIT EXTERIOR WALL EXTERIOR WALL (REFER TO GENERAL NOTES) � VOICE, DATA, BACKBONE& <br /> ALLOWED TO BE ATTACHED TO FROM WEB OF JOIST CEILING FOR CONDUIT FOR CONDUIT CCTV CABLES <br /> JOIST BOTTOM CHORD. REFER CABLE(S) ARE ALLOWED TO <br /> TO DETAIL 9/E511 FOR 1-1/2"X 1-1/2"X 12 GA STEEL BE SUPPORTED FROM FIRE ALARM, INSTRUSION, <br /> CONDUIT/CABLE JOIST BOTTOM CHANNEL WITH 1/2" DIA:BOLT P BOTTOM CHORD OF JOIST PAGING, EMS, COAX& <br /> CHORD LOAD REQUIREMENTS HOLES ON 1-1l2" CENTERS _ _ _ _ _ _ _ _ _ _ (REFER TO GENERAL NOTES) CONTROL CABLES MAY BE <br /> C H A N N E L P I P E S T R A P S I Z E VOICE, DATA, BACKBONE& SUPPORTED ON JOIST FLANGE <br /> AS REQUIRED � CCTV CABLES OR TOP OF BOTTOM CHORD <br /> I � OAP G13 � OAP G13 GENERAL NOTES: (REFER TO GENERAL NOTES) <br /> ) \ � GENERAL NOTES: A. REFER TO DETAIL 91E511 OR 8/E941 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. <br /> NOTES: `� TEMPERATURE TEMPERATURE A. REFER TO DETAIL 9/E511 OR 8/E941 FOR CONDUITICABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. S <br /> B. MINIMUM OF 3'SEPARATION BETWEEN DATA CABLES AND ALL OTHER LOW VOLTAGE CABLES. W�S , I� <br /> A. MOUNT TRAPEZE ASSEMBLY AS HIGH AS POSSIBLE, BUT MAINTAIN MIN 2"BELOW ROOF DECK. DO NOT SENSOR&HUMIDITY SENSOR&HUMIDITY g, MINIMUM OF 3"SEPARATION BETWEEN DATA CABLES AND ALL OTHER LOW VOLTAGE CABLES. v ,�, c�, f.� <br /> INTERFERE W/ WORK OF OTHER TRADES, BLOCK AIR DISTRIBUTION, FIRE PROTECTION OUTLETS OR LIGHT SENSOR SENSOR C. INSTALLATION OF LOW VOLTAGE CABLES SHALL COMPLY WITH NEC 760.8&800.24 -MECHANICAL EXECUTION OF y ° �' <br /> FIXTURES. EXTERIOR WALL EXTERIOR WALL C. INSTALLATION OF LOW VOLTAGE CABLES SHALL COMPLY WITH NEC 760.8&800.24-MECHANICAL EXECUTION OF WORK. �` � <br /> B. HANG FROM TOP CHORD PANEL POINT OF BAR JOIST. DO NOT EXCEED 100 LBS PER POINT WORK. �,� <br /> FINISHED GYP D. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. <br /> LOAD AT TOP CHORD OF JOIST BD WALL D. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. . "'�'�., R�=ci�L �v � <br /> NOTES: C. MAXIMUM OF 1"CONDUIT(S)ARE ALLOWED TO BE ATTACHED TO JOIST BOTTOM CHORD. REFER E. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE.CABLE SHALL BE INSTALLED IN A MANNER THAT NORMAL "�ss� �v <br /> ONALti <br /> A. DO NOT EXCEED 100 LBS PER POINT LOAD AT TOP CHORD OF JOIST TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. FINISHED INTERIOR WALL EXPOSED INTERIOR WALL E. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE.CABLE SHALL BE INSTALLED IN A MANNER BUILDING MOVEMENT WILL NOT DAMAGE CABLES. <br /> THAT NORMAL BUILDING MOVEMENT WILL NOT DAMAGE CABLES. <br /> LQ�I �O�TAGE CABLE SUF�PO�T LC�CATION Date of Signature: 02/05/2018 <br /> �2 f�Al'�GER LOAD S�PPORT S�CTlON �3 �ANGI(�� L�,�D SUPPC�RT DE�Al� 14 TE�IP SE�S06� OAP) NiOUNTfNG DE�"AI� �� DET/�IL - PARALLEL PERPE�aICULAR 16 LaV1l �fQ�TAGE CAB�E S�PF����� �O��TlO� D�TA9L - PERPEND�CU�� <br /> E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE <br /> � SECURE CHANNEL AT EACH <br /> 12 SECURE CHANNEL AT EACH �� END TO TOP CHORD OF BAR NOTES: <br /> CABLE(S)ARE ALLOWED TO BE E511 END TO TOP CHORD OF BAR E511 / JOIST AT PANEL POINT WITH A. INSTALL BATTERY ELIMINATOR TRANSFORMER(FURNISHED UNDER SECTION 08 7100). PROVIDE 120 VOLT <br /> SUPPORTED FROM TOP CHORD JOIST AT PANEL POINT WITH / TYPICAEL CLIP&SET SCREW. BRANCH CIRCUIT TO TRANSFORMER AND LOW VOLTAGE BATTERY ELIMINATOR. � <br /> OF JOIST(DO NOT EXCEED CHANNEL CLIP 8 SET SCREW. <br /> 100 LBS PER POWT LOAD AT , �� TYPICAL. '—�����__J�'�_� B. ROUTE CONDUCTORS TO LOW VOLTAGE TERMINALS OF BATTERY ELIMINATOR THROUGH CONCEALED 1/2"C � <br /> � MINIMUM 4"CLEAR FROM —J� TOP CHORD OF JOIST MOUNT TYPE MC CABLE <br /> BOTTOM OF ROOF DECK ) �� CA�BLES FROM WEB OF JO ST ,'% �`\� �� ASSEMBLY AS HIGH AS C. ROUTE CONDUCTORS TO DETEX HARDWARE THROUGH RACEWAY. PROVIDE FINAL CONNECTION TO DETEX � <br /> TO TOP OF CABLE /— DO NOT SUPPORT CABLES MULTI CONDUCTOR i i � i i ,, � �\�� POSSIBLE. MAINTAIN MIN 4" HARDWARE. �,�, <br /> FROM WEB OF JOIST TYPE MC CABLE, i i ,'% �``�� � <br /> BELOIN ROOF DECK. DO NOT � <br /> FIRE ALARM, INSTRUSION, <br /> PAGING, EMS, COAX& MOUNT TYPE MC CABLE �, � � �� �� <br /> CABLE(S)ARE ALLOWED TO BE i i i i ASSEMBLY AS HIGH AS �� % ' � � �, INTERFERE W/WORK OF <br /> CONTROL CABLES MAY � � OTHER TRADES, BLOCK AIR _ p � � <br /> SUPPORTED FROM BOTTOM POSSIBLE. MAINTAIN MIN 4" ` �� '� ' � � �` �%' DISTRIBUTION, FIRE BRANCH CIRCUIT WIRING � � g <br /> BE SUPPORTED ON °°°° o o ��� � %,� , ��` � ' -� STUB CONDUIT OUT OF EXTERIOR � <br /> CHORD OF JOIST(REFER TO BELOW ROOF DECK. DO NOT �� % o ��� PROTECTION OUTLETS OR <br /> � � � � � , � 12 VAC, 25 VA WALL.PROVIDE BUSHING. <br /> JOIST FLANGE OR GENERAL NOTES) � INTERFERE W/WORK OF � �, � — LIGHT FIXTURES. TRANSFORMER <br /> TOP OF BOTTOM __ =-_---___ � STANDARD STRUT CHANNEL : OTHER TRADES, BLOCK AIR ' 6'-0" ' 6'-0" ' � MULTI CONDUCTOR TYPE MC � � � <br /> CHORD(REFER TO WITH TYPE MC SADDLE CLAMP. DISTRIBUTION, FIRE <br /> GENERAL NOTES) ONLY VOICE, DATA, BACKBONE& PROTECTION OUTLETS OR � i CABLE CEILING U.N.O. �� �_ � <br /> � <br /> CCTV CABLES LIGHT FIXTURES. PROVIDE SUPPORT 6'-0"OC LOW VOLTAGE WIRING — . z <br /> DO NOT SUPPORT TYPE MC <br /> TYPE MC CABLES CAN 6E CABLES FROM WEB OF JOIST IN CONDUIT CONCEAL �' � <br /> SUPPORTED ON JOIST FLANGE IN WALL FURRING o �- <br /> OR TOP OF BOTTOM CHORD STANDARD STRUT CHANNEL <br /> GENERAL NOTES: (REFER TO GENERAL NOTES) WITH TYPE MC SADDLE CLAMP ` PROVIDE 1/2"C FOR SECURITY � <br /> i DOOR CONTACT °` � <br /> A. REFER TO DETAIL 91E511 OR 8lE941 FOR CONDUITICABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. TYPE MC CABLES ARE � i `� � <br /> TYPE MG CABLES ALLOWED TO ALLOWED TO BE SUPPORTED J-BOX PRE-INSTALLED IN DOOR <br /> B. MINIMUM OF 3"SEPARATION BETWEEN DATA CABLES AND ALL OTHER LOW VOLTAGE CABLES. BE SUPPORTED FROM BOTTOM FROM BOTTOM CHORD OF FLUSH MOUNTED J- � ,� HEADER FOR SECURITY CONTACT � C� <br /> CHORD OF JOIST(REFER TO JOIST(REFER TO GENERAL BOX FOR BATTERY � � � <br /> C. INSTALLATION OF LOW VOLTAGE CABLES SHALL COMPLY WITH NEC 760.8&800.24-MECHANICAL EXECUTION OF GENERAL NOTES) NOTES) ELIMINATOR(8E-96191) ,� SECURITY DOOR CONTACT, REFER � <br /> WORK. GENERAL NOTES: GENERAL NOTES: � TO DETAIL 2/E982 � <br /> A. TYPE MC CABLE ASSEMBLY SUPPORT IS REQUIRED FOR MC CABLE EXITING EDC AND A. TYPE MC CABLE ASSEMBLY SUPPORT IS REQUIRED FOR MC CABLE EXITING EDC AND ENTERING SALES LOW VOLTAGE WIRING — � � <br /> D. DO NOT�UN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. ENTERING SALES FLOOR. FLOOR. IN CONDUIT CONCEAL � STOREFRONT <br /> B. MAXIMUM OF 1"DIA TYPE MC CABLE(S)ARE ALLOWED TO BE ATTACHED TO JOIST SPAN IN WALL FURRING <br /> E. DO NOT SECURE CABLES TIGHTLY TO STRUCTURE. CABLE SHALL BE INSTALLED IN A MANNER THAT NORMAL BUILDING BOTTOM CHORD. REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD B. MAXIMUM QI= 1"DIA TYPE MC CABLE(S)ARE ALLOWED TO BE ATTACHED TO JOIST SPAN BOTTOM CHORD. � -'i GLASS DOOR � <br /> MOVEMENT WILL NOT DAMAGE CABLES. REQUIREMENTS, REFER TO DETAIL 9/E511 FOR CONDUIT/CABLE JOIST BOTTOM CHORD LOAD REQUIREMENTS. ROUTE CONDUIT TO �� � <br /> C. DO NOT RUN ANY TYPE OF CA6LE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE POINER DOOR HINGE � <br /> METAL DECKING. C. DO NOT RUN ANY TYPE OF CABLE BETWEEN THE TOP CHORD OF THE BAR JOIST AND THE METAL DECKING. <br /> � <br /> ��PE M� C�BLE S�1PP0�� TYPE I�C CA�LE �U�'PO�T Q�TA�L E����Ef�CY EXIT D00� (DETEX) L� <br /> 17 LQ�I VO�TAGE CA��E SUPP�Q�T LQC�TION DETAIL - PAF�LLEL �$ DETAIL PAf�ALLEL & PE�PEf��I��LA,f� 19 PARALLEL JOIST 2o F�� GLASS QOQ�S Al" STO�EFROC�T " ��� �r ��. � <br /> E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE <br /> E511 SCALE: NOT TO SCALE E511 SCALE: NOT TO SCALE <br /> s � � <br /> � <br /> , <br /> / � <br /> i <br /> � <br /> / <br /> � <br /> LIQUID TIGHT LIQUID TIGHT <br /> IMC <br /> Project Number �� <br /> � <br /> IFCONDUITLENGTH Proto:P188 Version:N/A Config:RR <br /> LIQUIDTIGHT BETWEEN CU&PIPING BOX IS <br /> COUPLING . LESS THEN 6'-0",THEN LIQUID Drawn By ,�� <br /> TIGHT IS ACCEPTABLE, <br /> Checked By J LS/T�C <br /> THERWI E U E M <br /> IMC � LIQUID TIGHT ���� �� � � �� � <br /> � ��� ��F�lH <br /> PIPE BOX CONDENSING UNIT <br /> 2� C��D��SE�G UNIT T�'PEC/�L CO�D��� �IaGF�A�I SIaEVlEV1f <br /> E511 SCALE: NOT TO SCALE <br /> 2/5/2018 11:42:40 AM <br /> � , ...:„.,�:: . . � , ,.�� . � . �:�... . . . .:..:_ . . . �.�Y.�: . . � . � . . . . . . . . - , � , � . � � � . „�,, . . <br /> . � <br /> , n�.: , ...„�- � <br /> > <br /> . . �-Y_.. � <br /> . . . . . . . . . . . <br /> .. <br /> C.` � . C.'. . P, . r3• . - �!: . '�.. . _ .,K.. ��„ , ;. _�. ` . `G!, sr?", c�'; tA'-'. 1i"', c�?' ce'." cA's 'P; c�?°. <br /> ....: <br /> r. . r. _ s. <br /> , , ,. .. ,. ,. .. , , . . . . . . , r. . . . . . . <br /> :�?' -�'-. <br />