HDTV ANTENNA PROVIDED BY
<br /> PROVIDE CONDUITS FOR LOW TARGET'S TV INSTALLATION '
<br /> 4"X 4"X 2 1/8"JUNCTION VOLTAGE(FA&EMS)CABLES. VENDOR i
<br /> BOX WITH COVERPLATE EXTEND CONDUITS A MINIMUM I
<br /> (TYPICAL) OF 18"ABOVE THE BOTTOM SATELLITE PROVIDED BY PROVIDE WP JUNCTION BOX, �
<br /> OF THE CONTROL CABINET. VENDO� INSTALL ON COLUMN PARAPET PENETRATION RG-11 COAX CABLE PROVIDED I
<br /> 1 3/8", �N LENGTH, RIGID LIQUIDTIGHT FITTING E9 �
<br /> GALV STEEL CHASE BUSH&SUPPORT CONDUITS. REFER TO 6/A142 BY TARGET'S LOW VOLTAGE � i
<br /> NIPPLE STUB(TYP) LIQUIDTIGHT CONDUIT PROVIDE GROUND BUS � SA�ELLITE�VENDOR(ONLY G BY VENDOR TARG E TOO
<br /> BAR. MOUNT ON COLUMN. ^
<br /> ANCHOR JUNCTION BOX , — � ' � � PARAPET COAX CABLE ROUTED BY 2"OD STD PIPE ANTENNA MAST,
<br /> TO FLOOR WITH CONCRETE 0 �� � � REQUIRED IN COLD AND PROVIDE 3/4"IMC
<br /> � � COAX CABLE PROVIDED �� � FREEZING RAIN CLIMATE Eg TARGET'S LOW VOLTAGE REFER TO 1/S141 AND 14IS522 1000 NICOLLET MALL
<br /> ANCHORS(TYP) ROUTE FEEDER CONDUIT � ,' �� i i i PROVIDE WP CONDULET VENDOR TO LOUNGE N
<br /> FLEXIBLE CONDUIT TO TO J-BOX ENCLOSING � � BY SATELLITE VENDO E9 i i FOR EACH PARAPET � � LOCATED IN ROOM 137 MINNEAPOLIS, MN 55403
<br /> PROVIDE BELL END THE UNIT DISCONNECT � � � �� PROVIDE GFCI WP PENETRATION. �
<br /> EQUIPMENT OR � � = i
<br /> RECEPTACLE ( � COAX CABLE ROUTED BY
<br /> CIRCUIT BREAKER. i � RECEPTACLE W/WP i—� EXTERIOR BUILDING SIGN GROUND LUG KIT PROVIDED BY
<br /> PROVIDE GROUND i i LOW VOLTAGE CONTRACTOR "WHILE IN USE"COVERPLATE ROOF PENETRATION PROVIDE BY SIGN VENDOR. 4 TARGET'S TV INSTALLATION
<br /> PROVIDE SHIM AS i i TO SATELLITE RECEIVER, REFER TO 2/A142 � A142 VENDOR
<br /> - � REQUIRED WIRE TO J-BOX. i � LOCATED IN CONTROL ROOM
<br /> .�. a° - ' - � d �'- SYSTEM FLOOR OUTLET � � �
<br /> ". :.'a:.-- � - _ ° -:.- TYPE'B' � i 4 i ROOF �
<br /> " - - — RIGID GALV STEEL COUPLING a_ _ - , ` ` � A142 � � �
<br /> EXTEND COUPLING 1l2"AFF _ � � .' °� ALL CONNECTIONS SHALL � � � i NOTE:
<br /> � ' BE LIQUID TIGHT.USE � � �� ' PROVIDE ONLY(1)ROOF i i RG-11 COAXIAL CONNECTORS
<br /> RIGID GALV STEEL -a ` ��< .a,, � a= -� � KNOCKOUTS PROVIDED. i � `� ' PENETRATION AT EACH PROVIDED BY TARGET'S
<br /> • COUPLING EXTEND " �°� � ' � NO OTHER PENETRATIONS ` , � ' — — — — ' � ROOF EXTERIOR BUILDING SIGN ��
<br /> CONDUIT AS REQUIRED COUPLING "AFF � , TV INSTALLATION VENDOR
<br /> ALLOWED. SEAL ALL � , M C F I T T I N G � LOCATION. REFER T 14 J
<br /> PVC COATED RIGID GALV UNUSED OPENWGS � - - '
<br /> STEEL CONDUIT(TYP) CONDUIT AS REQUIRED WITH EPCO DUCTSEAL COUPLING E521 EXTERIOR WALL � ���� �� ���� � � � � � �� ��
<br /> ADDITIONAL CONDUIT(IF COMPOUND. ��
<br /> REQUIRED) PVC COATED RIGID LIQUID TIGHT FITTING DETAIL POWER DISTRIBUTION
<br /> GALV STEEL CONDUIT
<br /> BOX PROVIDED BY SIGN VENDOR
<br /> (TYP� www.ctagroup.com
<br /> � FLOOR OUTLET TYPE 'A' 2 FLOOR OUTLET TYPE 'B' 3 RTU WIRING 4 SATELLITE DISH POWER & SYSTEMS DETAIL 5 BUILDING SIGN CONDUIT PENETRATION DETAIL 6 HDTV ANTENNA MAST DETAIL
<br /> E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: 1/4" = 1'-0"
<br /> NOTES: LIQUIDTIGHT FLEXIBLE
<br /> DO NOT USE SPRAY FOAM MATERIALS TO ,, CONDUIT TO EQUIPMENT OR
<br /> SEAL PENETRATIONS OR CONDUITS RECEPTACLE
<br /> �
<br /> RIGID GALV STEEL CONDUIT ''
<br /> STUB(TYP)
<br /> RIGID GALV STEEL COUPLING
<br /> '" ° � - " ' FLUSH WITH FLOOR(TYP)
<br /> , .a d_ o_ qo
<br /> - ' - ' . - � PVC COATED RIGID GALV
<br /> �° - STEEL CONDUIT(TYP) PARAPET MOUNTED CCN
<br /> VERTICAL SEALING FITTING
<br /> � CAMERA. REFER TO 5/A144
<br /> CONDUIT AS REQUIRED
<br /> AFTER WIRING WORK IS
<br /> COMPLETE FILL SEALING TYPE FD BOX WITH WEATHER- '
<br /> FITTING WITH SILICONE PROOF COVERPLATE AND
<br /> TOP OF PARAPET
<br /> CAULK. REFER TO SPEC DEVICE 1"LIQUIDTIGHT FLEX
<br /> SECTION 07 9200. CONDUIT AND FITTINGS
<br /> LIQUIDTIGHT FLEXIBLE WITH SERVICE LOOP Date NO. Description
<br /> i i INSULATION BY REFR. 0 0 CONDUIT TO EQUIPMENT OR O2/O6/'I H PERMIT ISSUE
<br /> � � CONTRACTOR. REFER TO RECEPTACLE
<br /> N � � 11/R501. ROOF FLASHING AND
<br /> i i MEMBRANE REFER WEATHERPROOF EXTERIOR
<br /> i i CAULK PENETRATION BOTH SIDES TO 2/A142 JUNCTION BOX.TOP OF BOX
<br /> � _ OF PANEL W/SILICONE CAULK MINIMUM 1"BELOW TOP OF
<br /> REFER TO SPEC B 0 RIGID GALV STEEL CONDUIT PARAPET. FILL ANCHOR HOLES
<br /> SECTION 07 9200 STUB(TYP) WITH SEALANT RECOMMENDED
<br /> 1"CONDUIT BY ROOF MANUFACTURER.
<br /> INSULATED PANEL CEILING RIGID GALV STEEL COUPLING EXTERIOR WALL
<br /> DRILL HOLES NO MORE THAN - - ' � - °- -` ° FLUSH WITH FLOOR(TYP) INTERIOR JUNCTION BOX
<br /> 1/8"BIGGER THAN CONDUIT a' a °.�.���� � PVC COATED RIGID GALV
<br /> SIZE - � STEEL CONDUIT(TYP)
<br /> RIGID CONDUIT
<br /> COOLER / FREEZER
<br /> 7 CONDUIT PENETRATION DETAIL 8 CONDUIT STUBS AND DEVICE BOX g EXTERIOR CCTV MOUNTING DETAIL �o NOT USED �� NOT USED �2 NOT USED
<br /> E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE
<br /> � ROOFDECK
<br /> PARAPET
<br /> VARIES �* PROVIDE SEISMIC BRACING *�
<br /> EXTERIOR BUILDING SIGN.VERIFY PROVIDE 3l4"IMC FOR
<br /> LOCATION AND REQUIREMENTS PARAPET PENETRATION � �2 -
<br /> W/SIGN VENDOR AND GC. REFER TO 6/A142 VARIE VARIES
<br /> �' - ELECTRICAL TRANSFORMER
<br /> � ' - VERIFY DIMENSIONS W/UNIT
<br /> � -
<br /> '� PROVIDE WP CONDULET � ROOF JOIST - - ROOF JOIST
<br /> � FOR EACH PARAPET -
<br /> PENETRATION. MICROLITE COVE SUSPENDED _
<br /> � FROM STRUCTURE ABOVE ACT
<br /> � CEILING MICROLITE - _
<br /> � � PROVIDE 3/4"IMC BETWEEN LED DRIVERTO BE LOCATED � � , COVE _ � _
<br /> '� CONDULETS(TYP)
<br /> ABOVE ACT CEILING I \�.��\� TYPE LT1 UNI-STRUT P1000 CHANNEL.
<br /> — ROOF DECK LOW VOLTAGE LEAD WIRES I LED COVE LIGHT LENGTHS AS REQUIRED FOR
<br /> � %� JOIST SPAN. TYPICAL OF TWO.
<br /> �� ' 1/2"ALL THREADED ROD WITH 2" CLAMP TO JOISTS WITH P1379S
<br /> ACT CEILING \ �\\� � AT CORNERS MOUNT FIXTURES WASHERAND DOUBLE NUTS CLAMPS.
<br /> ROOF PENETRATION ,%� BUTTED UP TOGETHER BOTH ENDS. TYP CAL 0 FTWO. V RHFY NEL
<br /> REFER TO 21A142 TYPE LT1 LED COVE LIGHT � ,% LENGTH WITH UNIT
<br /> SECURE TRANSFORMER DEMENSIONS.
<br /> MICROLITE COVE W �' � � � �. .
<br /> O, 2„ � � OLAT ON PAD OVIDE �� AS/�'
<br /> PROVIDE ONLY(1)ROOF
<br /> PENETRATION AT EACH > o�Ct�
<br /> EXTERIOR BUILDING �
<br /> w
<br /> SIGN � `�
<br /> Q �'l�
<br /> / ' 32006
<br /> � LOCATION. �� �� � j\ J � �o A �
<br /> / �o RCON�9 t�i
<br /> � VARIES � � � ' � , � � '`�ss�
<br /> � � �'
<br /> �3 NOT USED �4 BUILDING SIGN CONDUIT EL�EVATION DETAIL �5 MICROLITE COVE DETAIL LAZY RIVER �6 MICROLITE COVE PLAN DETAIL �� TRAPEZE MOUNTED DETAIL
<br /> E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE E521 SCALE: 1 1/2"= 1'-0" E521 SCALE: 1/4" = 1'-0"
<br /> Date of Signature: 02/05/2018
<br /> Q �
<br /> �
<br /> � /—\ �\ � ..
<br /> �
<br /> �
<br /> W
<br /> �
<br /> W
<br /> TRANSFORMER WEIGHT=500 LBS MAX >
<br /> PER UNIT —� UNISTRUT P1325 CORNER
<br /> CONNECTION OR EQUAL W
<br /> TYP) 3/16 0 ° ° o (TYP OF 4) �
<br /> VIBRATION ISOLATORS(SEE SPEC) 2@12
<br /> 1#4"STEEL PL
<br /> ' UNISTRUT P1000 1 5/8" ..
<br /> � OR EQUAL(TYP OF 2)
<br /> 0 0 ` SUPPORT L 3"X 3"X 1#4" X 4'-8" � �
<br /> o � � �
<br /> i L3"X3"X1#4" '
<br /> LOCATE @ EDGE OF TRANSFORMER M � � �
<br /> (4) 1/2"1 X 6"EXPANSION BOLT � � �
<br /> 0 o IN GROUTED CORES(TYP)
<br /> �� SUPPORT L 3"X 3"X 1#4" X 4'-8" 36"MAX UNISTRUT P1887 POST W �
<br /> VERIFY W/ BASE OR EQUAL �
<br /> EQUIPMENT (TYP OF 4) �
<br /> SUPPLIER ��/
<br /> � L�1�
<br /> �8 WALL MOUNTED TRANSFORMER DETAIL �g STACK MOUNTED TRANSFORMER DETAIL W
<br /> E521 SCALE: NOT TO SCALE E521 SCALE: NOT TO SCALE
<br /> W
<br /> � W
<br /> C�
<br /> �
<br /> O
<br /> �'
<br /> Project Number T�0337
<br /> Proto:P188 Version:N/A Config:RR
<br /> Drawn By (�S
<br /> Checked By Checker
<br /> ELECTRICAL
<br /> DETAILS
<br /> 2/5/2018 11:42:43 AM
<br /> . . ,.. . _. ,,-•, . , .,:. ,.;., . . y . .r ;r: . rr; ;ri: . -r;. • •
<br /> . _ _ .. _ . ,. ,. ,. .. :. . -�. , f. , r. . �. , t. , t. , f. . . • , � . � '!t` , � "�` •
<br /> .
<br /> . . . . . . . . . . . . . . . . . . . . . . . . . : .
<br /> ... . .,:.: .. -,�:. . ..,
<br /> . . . ,
<br /> .. . . . . . . . _ . _ . _
<br /> - - - ° , . .
<br /> - . . , , .
<br /> -
<br /> cr.t: .F:
<br />
|