ROUTE POWER CORD FOR
<br /> REFER TO MANUFACTURERS INSTALLATION INSTRUCTION DOCUMENTS FOR WIRING AND MOUNTING REQUIREMENTS FOR GONDOLA DISPLAY THROUGH.
<br /> - - - - - - - - - - - - - - - - - - - -
<br /> VALANCE LIGHTS.NOTE NOT ALL VALANCE DETAILS BELOW WILL BE APPLICABLE TO THIS PROJECT. REFER TO SHEET E121 FOR �� �� HOLES TO RECEPTACLE
<br /> I I LOCATED UNDERNEATH BASE - -
<br /> MORE INFORMATION ON WHAT DETAILS ARE APPLICABLE. i i DECK. �
<br /> i i FRONT VIEW
<br /> PROVIDE UNISTRUT CROSS CEILING � i I DRBASE DE�CK,
<br /> MEMBERS TO MOUNT LIGHT CENTER OF
<br /> �. FIXTURES BETWEEN CENTER CONDUIT i � ` O'� i PROVIDE BUSHING LIGHT FIXTURE MOUNTING I
<br /> RACKING SUPPORTS - TYPE VL1 LTG TYPE VL4 LTG TYPE VL5 LTG STUBOUT 2" O BRACKET. MOUNT BRACKET I
<br /> FIXTUR FIXTURE FIXTURE TYPE VL6 LTG � GONDOLA COOLER/FREEZER
<br /> E2 TYPE VL2 LTG E2 E2 ABOVE TOP OF i i TO PANEL UTILIZING HILTI
<br /> FIXTURE FIXTURE. FIXTURE E2 I O � I BASE DECK INSULATED CEILING
<br /> -
<br /> PANEL KWIK-PRO#12-14 HWH
<br /> i E2 � _ _ � 3E�FI DRENG H WITOH(ZINC COATED TA R E TOO
<br /> � BLOCKING RECEPTACLE POWER ROUTED FINISH OR EQUAL
<br /> BLOCKING
<br /> CENTER RACKING SUPPORTS � TYPE VL8 LTG �� UNDER BASE DECK TO POWER
<br /> POLE UP TO JUNCTION BOX PROVIDE EMT TO LIGHT 'I OOO NICOLLET MALL
<br /> i � TYPE VL7 LTG FIXTURE E2 E531 ABOVE CEILING. FIXTURES(TYP) MINNEAPOLIS, MN 55403
<br /> �� � TYPE"C10°LIGHT FIXTURE �
<br /> FIXTURE E2
<br /> � � LOCATED BETWEEN PALLET i z - SIM
<br /> i -
<br /> i RACKING CENTER SUPPORTS. � � a GONDOLA
<br /> � � � _ _ INSTALL FIXTURE
<br /> FIXTURE WIRE GUARD TO BE w � � w
<br /> � Y i Z � z 0'-0-1/2"ABOVE
<br /> � FLUSH WITH BOTTOM OF - _ � � o � z = a
<br /> � � Q � � BOTTOM OF
<br /> - - ' STRUCTURE CENTER BACKING � � i � x z �_ _ _ z -' a
<br /> SUPPORT). ( z N °�° � w w � a F � � a W �' w � z � SOFFIT PROVIDE LB SIDE VIEW
<br /> � ¢ � o I -� � � � w ~ I I � w � z > > � � AT CONDUIT
<br /> �- a '-'-' o w 'l' z � � � � �- � BRACKET SPACING REQUIRED.
<br /> w a I Y z � Y r � - x X
<br /> � z � o i LL � � o � c� � � � � = x a � � � � ,� PENETRATION 4'HOUSING-36"BETWEEN BRACKETS
<br /> � � � � � w Q � � Q LL � m � � > � a� � � '-'� a' o w � 8'HOUSING-49" BETWEEN BRACKETS
<br /> � X , m > �
<br /> " o ww � > � � � wo � � i i " o o u}.. � o � � NOTES:
<br /> �- W o � o LL � o � � � n ~ „� Q w Q WALK-IN COOLER/FREEZERS ARE CONSIDERED WET INTERIOR LOCATION, PROVIDE EMT INSIDE OF
<br /> � � � i � � � �-- i i w ¢ > z � � FLOOR COOLER/FREEZERS FOR LIGHTS ONLY.
<br /> i w Q � � � z �
<br /> � J > z PARTNER BUSINESS VALANCE LTGS @ PARTNER GONDOLA BASE DECK PROVIDE EMT FOR POWER FEED TO COOLER/FREEZER LIGHT FIXTURES. POWER FEED SHOULD ONLY PENETRATE �'` ��`""� � ����� �`� � � � � � � �
<br /> FLOOR � � i � i � LL BUSINESS(PHARMACY,OPTICAL, ETC...) COOLER/FREEZER ONCE AND BE CONNECTED AT EACH END OF LIGHT FIXTURE.
<br /> A+A VALANCE FOCAL VALANCE LTG'S HARDLINES VALANCE REFRIGERATION TV WALL VALANCE BIKE WALL VALANCE REFER TO MANUFACTURERS INSTALLATION INSTRUCTION DOCUMENTS SEAL PENETR,4TION WITH SILICONE CAULK.REFER TO SPECIFICATION SECTION 07 9200.
<br /> LTG'S AT PERIMETER WALL LTG'S AT PERIMETER VALANCE LTG'S AT LTG'S AT PERIMETER LTG'S AT PERIMETER FOR WIRING AND MOUNTING REQUIREMENTS FOR VALANCE LIGHTS. � �
<br /> AT PERIMETER WALL WALL PERIMETER WALL WALL WALL - - REFER TO SPECIFICATION SECTION 26 0533-3.3 FOR CONDUIT USES PERMITTED. www.ctagroup.com
<br /> COOLER/FREEZER LIGHT FIXTURE MOUNTING
<br /> � PALLET RACKING LIGHT FIXTURE MOUNTING 2 PERIMETER WALL VALANCE LIGHTING SECTIONS 3 PARTNER BUSINESS LIGHTING SECTIONS 4 UNDER BASE DECK RECEPTACLE DETAIL 5 DETAIL
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE
<br /> NOTE: NOTE: CONNECTOR BRACKET
<br /> POWER CONDUCTORS GREATER THAN 70 VOLTS ARE REQUIRED TO BE IN FLEXIBLE CONDUIT POWER CONDUCTORS GREATER THAN 70 VOLTS ARE REQUIRED TO BE IN FLEXIBLE CONDUIT FURNISHED BY FIXTURE '
<br /> VENDOR �' SURFACE MOUNT JUNCTION ,
<br /> MANUFACTURED MANUFACTURED BOX 12"ABOVE LAY-IN CEILING
<br /> STARTER AND CABLE STARTER AND CABLE MAKE CONNECTION TO ON EXTERIOR WALLS, MOUNT
<br /> KIT KIT LIGHTING FIXTURE ON TOP PLATE OF INTERIOR
<br /> JUNCTION BOX POWER PASS THRU CABLE KIT POWER PASS THRU CABLE KIT WALLS. I
<br /> CEILING SOURCE ROUTED TO BASE DECK OF SOURCE ROUTED TO BASE DECK OF CEILING
<br /> FIXTURE
<br /> � NYLON BUSHING � POWER POLE TYPE"b"&°c" POWER POLE � ~ I
<br /> \� PROVIDE 3/8"MC FROM J-BOX MTD
<br /> POWER&DATA CABLE ROUTED � ARE PROVIDED WITH FOOT BRACKET ABOVE CEILING TO 90 DEG. SNAP-
<br /> THROUGH POWER POLE TO J-BOX MOUNTED ON PRE-INSTALLED CABLE KIT � IN CONNECTOR. ,
<br /> STRUCTURE ABOVE J-BOX MOUNTED ON ANCHOR FOOT BRACKET TO FIXTURE '
<br /> JUNCTION BOX ABOVE CEILING ACCESSIBLE CEILING CEIL�NG TRIM KIT STRUCTURE ABOVE CONNECTED TO PRE-INSTALLED WITH 1/4"X 1/2" � GYP BD
<br /> ACCESSIBLE CEILING POWER POLE RECEPTACLE ROUTE MC CABLE VIA
<br /> CEILING T-BAR SYSTEM PANHEAD SHEET METAL FIXTURE CHANNEL PROVIDE PLASTIC 01 RUBBER GROMMET
<br /> NYLON BUSHING SCREWS. PRE-DRILL FIXTURE.
<br /> SECURE POWER POLE TO CENTER FOOT BRACKET OVER POWER POLE 318"90 DEG.SNAP-IN MC CONNECTOR Date NO. Description
<br /> TOP OF MAC POWER POLE PRE-PIJNCHED KNOCK-OUT PROVIDED PROVIDED BY OWNER.
<br /> TYPE"b"PROVIDED WITH FIXTURE TOP INSTALL POWER POLE INSTALL VALANCE LIGHT AND CONNECT OZ/O6/'I H PERMIT ISSUE
<br /> PRICE SCANNER WITH(1)DUPLEX CEILING T-BAR SYSTEM CAP. PUNCH FIXTURE TOP CAP MOUNTING BRACKET MANU AC URERSPNSTALLATION
<br /> RECEPTACLE. IF KNOCK-OUT IS NOT FURNISHED WITH POWER POLE
<br /> MAC PHONE POWER POLE CEILING TRIM KIT PRESENT. - INSTRUCTION. E2
<br /> TYPE"c"PROVIDED �
<br /> POWER POLE ACCESS PANEL W/ WITH (2)DUPLEX POWER POLE ACCESS PANEL W/ �
<br /> Q _ 1/2"KNOCK-OUT ON EACH END RECEPTACLES. � 1/2"KNOCK-OUT ON EACH END �� ,
<br /> - - - ' � �
<br /> ROUTE CABLE KIT �' � 9 ROUTE CABLE KIT �' o � 9 PROVIDE FINAL ELECTRICAL CONNECTION
<br /> TO BASE DECK OF � ' E531 TO BASE DECK OF � E531 TO VALANCE LIGHT FIXTURE WIRING
<br /> FIXTURE AND � FIXTURE AND � HARNESS PER MANUFACTURERS
<br /> TERMINATE IN TERMINATE IN INSTALLATION INSTRUCTION.
<br /> J-BOX FOR MAIN J-BOX FOR MAIN
<br /> POWER FED TO POWER FED TO NOTE:
<br /> MAIN AISLE FIXTURE FIXTURE FLUORESCENT VALANCE VERIFY LOCATION OF VALANCE WITH ELECTRICAL FLOOR PLANS AND
<br /> LIGHTING FURNISHED AND FINAL STORE FIXTURE PLAN.WHEN FIXTURE WSTALLATION IS COMPLETE.
<br /> INSTALLED BY FIXTURE ENERGIZE VALANCE LIGHT FIXTURE AND ENSURE PROPER
<br /> VENDOR OPERATION OF EACH VALANCE LIGHT FIXTURE.
<br /> POWER POLE
<br /> 6
<br /> MINI-ASSISTANCE CENTER MAC DETAIL 7 POWER POLE TYPE "a" INSTALLATION DETAIL $ TYPE "b" & "c" INSTALLATION DETAIL 9 POWER POLE MOUNTING DETAIL �o GREETING CARDS LIGHT FIXTURE DETAIL 11 FOCAL LIGHTING VALANCE
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> HOMERUN 1 1/4"EMC HOMERUN 1 1/4"EMC
<br /> #10 NO SPLICES #10 NO SPLICES
<br /> CEILING �
<br /> CEILING
<br /> REAR SIDE(TOWARDS
<br /> REAR OF STORE)
<br /> POWER POLE LED LANE LIGHT
<br /> 159"WALL HEIGHT- VL2 VALANCE LIGHT 1 1/4"EMT LED DRIVER
<br /> 114"WALL HEIGHT-VL3 VALANCE LIGHT CEILING
<br /> LOW VOLTAGE
<br /> ROUTE 3/8"MC CABLE FROM ► FALSE COLUMN SWITCH LOCATIONS
<br /> - - - - J-BOX UNDER BASE DECK � FALSE COLUMN AT 58"AFF
<br /> THROUGH STORE FIXTURE � PROVIDE 6"X 6"PULL BOX, � PROVIDE 6"X 6"PULL BOX,
<br /> TO VALANCE LIGHT,TYPICAL FASTEN TO TOP OF FASTEN TO TOP OF � PROVIDE 6"X 6" PULL BOX, LANE LIGHT CHANNEL
<br /> � REFRIGERATED CASE � REFRIGERATED CASE FASTEN TO TOP OF GUEST SIDE
<br /> I REFRIGERATED CASE — ( REFRIGERATED CASE POWER CHANNEL
<br /> � I I
<br /> (2) 1" EMT - (2)1"EMT ATTACHED TO
<br /> � REFRIGERATED CASE TELEIDATA CHANNEL
<br /> I I
<br /> � I I
<br /> I I
<br /> I I
<br /> I I
<br /> I � (2) 1" FLEX p, S.
<br /> O F wA
<br /> REFER TO MANUFACTURERS INSTALLATION INSTRUCTION MOUNT J-BOX UNDER � (2) 1" FLEX I (2) 1" EMT OR FLEX y � o�G��
<br /> DOCUMENTS FOR WIRING AND MOUNTING REQUIREMENTS FOR BASE DECK,TYPICAL � TERMINAL STRIP � (2) 1" FLEX (2) 1"FLEX
<br /> VALANCE LIGHTS. � IN WIREWAY �
<br /> ROUTE MC CABLE THROUGH !�
<br /> BASE DECK TO EACH J-BOX, JUNCTION BOX FRONT SIDE(TOWARDS A,po R,�1° -o �
<br /> TYPICAL FRONT OF STORE) F�SS�oNA�.�'
<br /> WIRING/CONDUIT BETWEEN CASES IF NO WIREWAY
<br /> �2 HARDLINES VALANCE LIGHTING WIRING DETAIL 13 REFRIGERATED CASE FRONT VIEW �4 REFRIGERATED CASE SIDE VIEW �5 RIGHT HAND CHECKLANE POWER POLE Date of Signature: 02/05/2018
<br /> E531 SCALE: NO SCALE
<br /> E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> F TRI-TRONICS UNIT
<br /> �F MOTOR CAPACITOR BOX (CHECKLANE
<br /> (BELTMOTORSTARTER) CONTROLLER) CHECKLANE GENERAL NOTES
<br /> E❑ MAINT. RECEPTACLE C (3)4"X4"J-BOXES Q
<br /> (GRAY) A. CHECKLANE FURNISHED WITH JUNCTION BOXES, DEVICES&
<br /> �E COOLER WIRING AS INDICATED. �
<br /> � SCANNER RECEPTACLE
<br /> RECEPTACLE (GRAY) B. TELEPHONE AND POS DATA CABLE BY VOICE/DATA �
<br /> (IVORY) CONTRACTO E5 �
<br /> � �
<br /> � C. CHECKLANE POWER POLE SWITCHES, FLEX WIRING, LANE LIGHT
<br /> ASSEMBLY, FURNISHED BY POWER POLE VENDOR. W
<br /> I..L
<br /> D. COORDINATE LIGHT FIXTURE LOCATIONS WITH CASH REGISTER �
<br /> � � POWER POLES.WHERE NECESSARY MOVE LIGHT FIXTURES TO �
<br /> D LANE LIGHT AVOID POWER POLES. MOVE LIGHT FIXTURES IN THE SAME �
<br /> � DIRECTION.
<br /> �F BELT SWITCH FLEX WIRING W
<br /> B❑ (1)CONV. CIRCUIT A POWER POLE E. GRAY CIRCUIT INDICATES NORMAL POWER FED FROM LP-3. `
<br /> INPUT FLEX,(1) � &LANE LIGHT IVORY CIRCUIT INDICATES STANDBY/GENERATOR POWER FED r
<br /> COOLER CIRCUIT ASSEMBLY FROM
<br /> INPUT FLEX&
<br /> LPE-1 OR UPS-1. .. �
<br /> (1)STANDBY/GEN E POS RECEPTACLE F. (3)LABELLED JUNCTION BOXES(CHECKLANE)FURNISHED AND
<br /> (IVORY) MOUNTED ON SIDE PANEL OF CHECKLANE BY CHECKLANE 6 � �
<br /> CIRCUIT INPUT 601 � � �
<br /> FLEX WIRING F CATALINA PRINTER RECEPTACLE VENDOR. N
<br /> �'�°RY� CHECKLANE KEY NOTES 603 TYP W —� �
<br /> FRONT SECTION REAR SECTION 601 INSTALL PRE MANUFACTURED POWER DISTRIBUTION BOX ABOVE ACCESBILE CEILING. Q �
<br /> A❑ INSTALL CHECKLANE SIGN PRIOR TO INSTALLATION OF POWER � �
<br /> POLE TO CHECKLANE. ONCE SIGN IS INSTALLED, INSTALL AND 602 INSTALL PRE MANUFACTURED MAINRUN CABLE FROM POWER DISTRIBUTION BOX TO
<br /> SECURE BOTTOM OF POWER POLE TO CHECKLANE WITH PANEL. ! f ' �
<br /> WHITE MOUNTING �■■� �
<br /> TO REAR SECTION POS RECEPTACLE(IVORY). (NEUTRAL) TO SCANNER RECEPTACLE(IVORY), (FLEX PREWIRED BRACKET FURNISHED BY POWER POLE VENDOR. SECURE TOP OF 603 INSTALL PRE MANUFACTURED EXTEND CABLE FROM POWER DISTRIBUTION BOX TO 3
<br /> CONNECT FLEX WIRING FURNISHED BY VENDOR. TO J-BOX BY VENDOR). POWER POLE PER DETAIL SPLITTER MOUNTED IN BASE DECK. � W
<br /> B� PROVIDE FLEX WIRING AND ROUTE VIA POWER SECTION OF � �
<br /> POWER POLE AND MAKE CONNECTIONS�N LABELLED JUNCTION
<br /> GREEN � BLACK BOXES INSIDE OF CHECKLANE.
<br /> (GND) (HOT) �
<br /> ❑C JUNCTION BOXES FURNISHED AND INSTALLED BY CHECKLANE � , I , . >
<br /> VENDOR. PROVIDE CONNECTIONS INSIDE LABELLED JUNCTION � I �� _ �
<br /> STANDBY/GENERATOR POWER INPUT CIRCUIT BOXES INSIDE OF CHECKLANE. i
<br /> (LPE-1 OR UPS-1). PROVIDE FLEX WIRING AND ,� �
<br /> CONNECT. �D ROUTE FLEX WIRING(FURNISHED WITH POWER POLE)AND MAKE INSTALL OWNER FURNISHED RELOC � 60"AFF i GENERALIFIXTURE CONTRACTOR TO VERIFY IF END W
<br /> COMPUTER EQUIPMENT HARDWIRE CONNECTION TO CONVENIENCE POWER JUNCTION WIRING SYSTEM EXTENDER CABLES IN � i CAP DISPLAY REQUIRES POWER&SYSTEMS. _ _ '^
<br /> (POS/SCANNER POWER,� BOX INSIDE CHECKLANE. BOTTOM OF MULTI-OUTLET ASSEMBLY � �� i PROVIDE 2"HOLE THROUGH END FRAME V J
<br /> J-BOX. PROVIDE FINAL CONNECTION � 60"AFF � � PEG BOARD DIRECTLY BEHIND DISPLAY WERE �
<br /> �E DEVICE&FLEX WIRING FURNISHED&PREWIRED AT DEVICE BY USING IDEAL CONNECTORS PROVIDED � i � CORD EXITS THE DISPLAY. PROVIDE GROMMETS TO
<br /> WITH MULTI-OUTLET ASSEMBLY KIT, i � PROTECT POWER&SYSTEMS CABLES. GROMMET �
<br /> TO MAINTENANCE RECEPTACLE(GRAY). (FLEX WHITE CHECKLANE VENDOR. PROVIDE CONNECTIONS IN LABELLED � i
<br /> PREWIRED TO J-BOX BY VENDOR). (NEUTRAL) JUNCTION BOXES INSIDE OF CHECKLANE. ,� i i i COLOR SHALL MATCH FIXTURE COLOR. �
<br /> � 60"AFF I I
<br /> GREEN BLACK � DEVICE&FLEX WIRING FURNISHED&PREWIRED BY CHECKLANE \� i \ O
<br /> VENDOR. � � i RECEPTACLE MOUNTED
<br /> (GND) (HOT) i 6o",�FF i i �— UNDER BASE DECK
<br /> ��' � TO FIXTURE RAILARM Project Number ��'0 3 3 7
<br /> TO LANE LIGHT CIRCUIT(LP-3). CONVENIENCE INPUT CIRCUIT(LP-3). PROVIDE FLEX � i i
<br /> CONNECT FLEX WIRING FURNISHED BY WIRING&CONNECT. i 6°•'AFF � i
<br /> VENDOR. CHECKSTAND 60"AFF \\� � � �
<br /> � \ MOUNT BASE DECK RECEPTACLE Proto:P188 Version:N/A Config:RR
<br /> � TO FIXTURE RAIL WITH 1/4' X 1"
<br /> (CONVENIENCE POWERI ii'' i i i ROUTE PRE-MANUFACTURED � 0� PANHEAD SHEET METAL SCREWS. DI"aWll B
<br /> � W I R I N G I N B A S E D E C K O F � , _ P R E-D R I L L F I X T U R E R A I L A S R E Q U I R E D Y R S
<br /> FIXTURE , - - - - - - - - - - - - - - - - - - - - �
<br /> i ii � i
<br /> ��ii � i �
<br /> TO COOLER RECEPTACLE(GRAY). (FLEX WHITE ii J � I I
<br /> �� , � Checked By J LS/TK
<br /> PREWIRED TO J-BOX BY VENDOR). (NEUTRAL) i�ii � i � `� i i
<br /> ��ii i SUPPORT PRE-MANUFACTURED CONNECTORS A MINIMUM 3"ABOVE O ��i � �. � O �i
<br /> GREEN BLACK �i�� � �� FINISHED FLOOR FROM UNDERSIDE OF BASE DECK TO AVOID i i
<br /> (GND) (HOT) pii � MOISTURE FROM PENETRATING CONNECTORS. SUPPORT i
<br /> i�p � CONNECTORS ON EACH END UTILIZING SUPPORT WIRES OR STRAPS TYPICAL GONDOLA �
<br /> ��.�\� I��' � ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE ISOMETRIC VIEW � 3 7z„ TYPICAL GONDOLA RAIL � E L E CT R I CAL
<br /> COOLER INPUT CIRCUIT(LP-3). PROVIDE FLEX ��� BASE DECK COVER. � ,
<br /> WIRING AND CONNECT. \\���`��
<br /> TYPICAL.
<br /> - - - - - - - - - - - - - - - -
<br /> SODA COOLER � D E TA I L S
<br /> MAINTAIN 3 1/2" OF CLEARANCE
<br /> ( LER POWERI
<br /> FROM BACK OF FIXTURE RAIL
<br /> LENGTH OF GONDOLA LENGTH OF GONDOLA WHEN INSTALLING BASE DECK
<br /> 1314"x 4"JUNCTION BOXES WILL VARY WILL VARY RECEPTACLE.
<br /> 16 CHECKLANE ,7 BEAUTY PLUGSTRIP - TYPICAL WIRING �$ BEAUTY BLOWOUT RECEPTACLE - TYPICAL WIRING 19 RECEPTACLE INSTALLED UNDER BASE DECK
<br /> E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE E531 SCALE: NOT TO SCALE
<br /> E531 SCALE: NOT TO SCALE
<br /> 2/5/2018 11:42:47 AM
<br /> . ... . . . , . . .. . . . .
<br /> , , .
<br /> � .�w.� . � �
<br /> .,,. . ..
<br /> ... �u.� - -
<br /> -..-- .-
<br /> . . .�,�A.'�.. � , .. . — S��^d.. � `� . � � �� .;r.-�, � •� . . . .r.�, � `� . � . . �- ;A.'... � •. . '. ..-i."-�.. � `�.� . � . ^R°�.. � . �.rF'.. � . . . .:�C'°: � . . �,rr.'rt � ,rC.'°, . TF... � . . -i'��c. � . ,r�P��,: � . �^s°'�„ � . . ;r�i'-=.: � . . . ;cr.�,: � . .. :i.'°; � . -r.-'.. � . . -r.`, � . rk', �
<br /> : :� .,.�«::. .. , .,:, .. : ..;
<br /> . � . . . .,. . ... . , .Y. . .. . .,. . .. . . .,. . � . .,. . .. . .�:. . , .... .t.. . � . . t . � . . . . . . . . . . . t . f . . . . . . . � . . .
<br />
|