Laserfiche WebLink
I <br /> 1 The last sentence of the fifth paragraph is revised to read: <br /> 2 <br /> 3 With the Engineer's written concurrence, microsilica fume may be used in all <br /> 4 classifications of Class 4000, Class 3000, and commercial concrete and is limited to a <br /> 5 maximum of 10 percent of the cementitious material. <br /> 6 <br /> 7 6-02.3(2)A Contractor Mix Design <br /> 8 The last sentence of the last paragraph is revised to read: <br /> 9 <br /> 10 For all other concrete, air content shall be a minimum of 4.5 percent and a maximum of <br /> 11 7.5 percent for all concrete placed above the finished ground line unless noted otherwise. <br /> 12 <br /> 13 6-02.3(2)A1 Contractor Mix Design for Concrete Class 4000D <br /> 14 Item number 5 of the first paragraph is deleted. <br /> 15 <br /> 16 Item number 6 of the first paragraph (after the preceding Amendment is applied) is renumbered <br /> 17 to 5. <br /> ' 18 <br /> 19 6-02.3(2)B Commercial Concrete <br /> 20 The second paragraph is revised to read: <br /> ' 21 <br /> 22 Where concrete Class 3000 is specified for items such as, culvert headwalls, plugging <br /> 23 culverts, concrete pipe collars, pipe anchors, monument cases, Type PPB, PS, I, FB and <br /> ' 24 <br /> 25 RM signal standards, pedestals, cabinet bases, guardrail anchors, fence post footings, <br /> sidewalks, concrete curbs, curbs and gutters, and gutters, the Contractor may use <br /> 26 commercial concrete. If commercial concrete is used for sidewalks, concrete curbs, curbs <br /> 27 and gutters, and gutters, it shall have a minimum cementitious material content of 564 <br /> 28 pounds per cubic yard of concrete, shall be air entrained, and the tolerances of Section 6- <br /> 29 02.3(5)C shall apply. <br /> 30 <br /> ' 31 6-02.3(4) Ready-Mix Concrete <br /> 32 The first sentence of the first paragraph is revised to read: <br /> 33 <br /> 34 All concrete, except lean concrete, shall be batched in a prequalified manual, semi- <br /> 35 automatic, or automatic plant as described in Section 6-02.3(4)A. <br /> 36 <br /> 37 6-02.3(4)D Temperature and Time For Placement <br /> 38 The following is inserted after the first sentence of the first paragraph: <br /> 39 <br /> 40 The upper temperature limit for placement for Class 4000D concrete may be increased to <br /> 41 a maximum of 80°F if allowed by the Engineer. <br /> 42 <br /> 43 6-02.3(5)C Conformance to Mix Design <br /> 44 Item number 1 of the second paragraph is revised to read: <br /> 45 <br /> 46 1. Cement weight plus 5 percent or minus 1 percent of that specified in the mix design. <br /> ' 47 <br /> 48 6-02.3(6)A1 Hot Weather Protection <br /> 49 The first paragraph is revised to read: <br /> 50 <br /> 51 The Contractor shall provide concrete within the specified temperature limits. Cooling of <br /> 52 the coarse aggregate piles by sprinkling with water is permitted provided the moisture <br /> CITY OF EVERETT AMENDMENTS <br /> PACIFIC AVENUE TO INTERURBAN TRAIL BICYCLE SAFETY PROJECT 8/12/2019 <br /> STATE FUND#HLP PB17(014); COE#PW3688 Page AM-35 <br />