My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7501 HARDESON RD SAFRAN ELECTRONICS 2016-05-23
>
Address Records
>
HARDESON RD
>
7501
>
SAFRAN ELECTRONICS
>
7501 HARDESON RD SAFRAN ELECTRONICS 2016-05-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/23/2016 1:16:29 PM
Creation date
5/23/2016 1:16:27 PM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7501
Tenant Name
SAFRAN ELECTRONICS
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. • • <br /> ROBERTS ENGINEERING PLLC <br /> 17503 NE 137TH STREET <br /> August 5,2014 REDMOND,WA 98052-2182 <br /> Mr.Michael Caniglia <br /> Wetherholt and Associates, Inc. <br /> 13104 NE 85th Street <br /> Kirkland,WA 98083-0816 <br /> Dear Mr. Caniglia: <br /> As requested, I obtained the building permit set of drawings for the building at 7501 Hardeson <br /> Road, Everett, WA from the Everett Building Department. I have a one-half sized set of the <br /> drawings which I will drop off at your office in the very near future. <br /> The Structural Notes on Drawing S-5 show that the roof was designed for the following loads: <br /> Snow Load =25 psf <br /> Dead Load= 15 psf <br /> Using the roof assembly information you provided, I calculated the follow dead loads for the roof: <br /> 5.2"thick polyiso insulation = 0.87 psf (2 pcf density) <br /> 'A" Sarnatherm M= 0.38 psf(per manufacturer) <br /> Sarnafil G410 60 mil roof membrane= 0.39 psf(per manufacturer) <br /> OSB Sheathing= 1.7 psf(per Boise Cascade) <br /> 6 mil Polyethylene Vapor Barrier= 0.03 psf <br /> 2x6 @ 24"o.c. Roof Framing= 1.7 psf(per Boise Cascade) <br /> 36LH09 Steel Joists a, 10' o.c. = 2.1 psf(per Vulcraft) <br /> Total DL= 7.17 psf <br /> Based on the Structural Notes there appears to be approximately 6 psf for miscellaneous loads such <br /> as light fixtures and fire sprinklers which I believe to be a sufficient allowance. <br /> I then checked the adequacy of the actual framing members. <br /> 2x6#2 DF Adequate for a 12 psf DL <br /> 36LH09 Steel Joists Adequate for an 18 psf DL <br /> 32LH08 Steel Joist Adequate for a 15 psf DL <br /> 44G 4N 20.5K Steel Joist Girder Adequate for a 14 psf DL <br /> 44G 4N 19.5K Steel Joist Girder Adequate for a 14 psf DL <br /> 44G 5N 19.5K Steel Joist Girder Adequate for a 14 psf DL <br />
The URL can be used to link to this page
Your browser does not support the video tag.