My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-03 2019-10-31
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-03
>
3003 W CASINO RD BLDG 45-03 2019-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2019 2:37:56 PM
Creation date
10/31/2019 2:37:07 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-03
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
45-03 BUILDING FACP POINTS 45-03 HANGER SUPPRESSION FACP POINTS FIRE ALARM ABBREVIATIONS* LEGEND <br /> POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT— COMMENTS — GRID/SHEET LOC. POINT NUMBER/ZONE BOEING DESCRIPTION FACP POINT— COMMENTS — GRID/SHEET LOC. ALT SECONDARY OR ALTERNATE ELEVATOR RECALL <br /> SV45-20 WF WATERFLOW SWITCH E/5.7 — E506-2 1:17 UV45-24A TAMPER OS&Y SPRINKLER VALVE G—.5 — 1E260 BEAM DET BEAM DETECTOR <br /> SV45-20 TAMPER SPRINKLER PIV D/5 OUTSIDE OF FOAM ROOM — 1E260 1:14 11V45-24A WF WATERFLOW SWITCH G-.5 — 1E260 CDR COMPUTER/NETWORK/DATA/IDE ROOM <br /> SV45-21 WF PRESSURE WATERFLOW PRESSURE R.5/1 — 1E264 1:30 W45-24B TAMPER OS&Y SPRINKLER VALVE C-10 — 1E261 COL COLUMN <br /> WATERFLOW ISOLATION TAMPER SWITCH R.5 1 — 1E264 COMM FAIL COMMUNICATION FAILURE <br /> SV45-21 WF ISO TAMPER / 1:27 W45-24B WF WATERFLOW SWITCH C-10 — 1E261 CTRL CONTROL <br /> SV45-21 TAMPER SPRINKLER PIV R.5/0 (NEXT TO 45-06) — 1E264 2:24 UV45-24C TAMPER OS&Y SPRINKLER VALVE P-10 — 1E265 CW CATWALK <br /> SV45-22 TAMPER SPRINKLER PW D/5 OUTSIDE OF FOAM ROOM — 1E260 2:21 UV45-24C WF WATERFLOW SWITCH P-10 — 1E265 DMPR DAMPER <br /> SV45-22 WF WATERFLOW SWITCH E/5.5 — E506-2 2:11 UV45-24D TAMPER OS&Y SPRINKLER VALVE L-4.5 — 1E262 DD DUCT SMOKE DETECTOR <br /> DIESEL DIESEL <br /> SV45-24 WF WATERFLOW SWITCH E/6.25 — E506-2 2:8 UV45-24D WF WATERFLOW SWITCH L-4.5 — 1E262 FP FIRE PUMP <br /> SV45-24 TAMPER SPRINKLER PIV D/5 OUTSIDE OF FOAM ROOM — 1E260 1:18 AF45-24A TAMPER SPRINKLER VALVE G-.5 — 1E260 ELEC ELECTRICAL; ELECTRICAL ROOM <br /> SV45-26 TAMPER SPRINKLER PIV D/5 OUTSIDE OF FOAM ROOM — 1E260 1:31 AF45-24B TAMPER SPRINKLER VALVE C-10 — 1E261 ELEV ELEVATOR <br /> SV45-26 WF WATERFLOW SWITCH E/6 — E506-2 2:25 AF45-24C TAMPER SPRINKLER VALVE P-10 — 1E265 EPP EXCESS PRESSURE PUMP <br /> FACP FIRE ALARM CONTROL PANEL <br /> SV45-28 TAMPER SPRINKLER PIV 0/5 OUTSIDE OF FOAM ROOM — 1E260 2:12 AF45-24D TAMPER SPRINKLER VALVE L-4.5 — 1E262 ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR <br /> SV45-28 WF WATERFLOW SWITCH E/6 — E506-2 AFFF TANKS A—D TAMPER SPRINKLER VALVE E/4.75 — E506-2 FLR FLOOR <br /> RE <br /> SV45-34 WF WATERFLOW SWITCH E/6.25 — E506-2 AFFF MAIN VLV TAMPER SPRINKLER VALVE E/4.75 — E506-2 FM HEA MAIN VALVE GENERAL N OTES <br /> HEAT HEAT DETECTOR <br /> SV45-34 TAMPER SPRINKLER PIV D/5 OUTSIDE OF FOAM ROOM — 1E260 TANK C/D MAIN VLV TAMPER SPRINKLER VALVE E/5 — E506-2 INTDEV INTERFACE DEVICE, MONITORING OR CONTROL 7->FIRE CANNON FACP REPORTS GENERAL ALARM, <br /> W45-20A TAMPER OS&Y SPRINKLER VALVE F/2 CATWALK — 1E260 FOAM CTRL TANK D TAMPER OS&Y SPRINKLER VALVE E/5 — E506-2 ISO ISOLATION VALVE TROUBLE AND SUPERVISORY SIGNALS TO THE 45-03 <br /> W45-20A WF PRESSURE WATERFLOW PRESSURE F/2 CATWALK — 1E260 WATER CTRL TANK C TAMPER TANK C SPRINKLER VALVE E/5 — E506-2 KITCHEN KITCHEN BUILDING FACP. <br /> L BATT LOW BATTERY <br /> W45-20B TAMPER OS&Y SPRINKLER VALVE E/5.7 — E506-2 WATER CTRL TANK D TAMPER TANK D SPRINKLER VALVE E/5 — E506-2 L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) <br /> UV45-20B HI/L0 AIR HI/LO AIR PRESSURE SWITCH E/5.7 — E506-2 1:5 SMK ® FACP COL. E-5 — E506-2 LBY LOBBY <br /> UV45-20B WF WATERFLOW PRESSURE SWITCH E/5.7 — E506-2 1:6 MAN PULL COL. D-4 — E506-2 LRD LOW RATE DISCHARGE <br /> UV45-21A TAMPER OS&Y SPRINKLER VALVE R.5/1 — 1E264 1:7 MAN PULL COL. E-2 — 1E260 MAN PULL MANUAL PULL STATION <br /> MACH MECHANICAL ROOM <br /> UV45-21A WF PRESSURE WATERFLOW PRESSURE SWITCH R.5/1 - 1E264 1:8 MAN PULL COL.J-0 — 1E262 NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> UV45-22A TAMPER OS&Y SPRINKLER VALVE E/5.5 — 1E506-2 1:9 MAN PULL COL. L-1 — 1E262 OS&Y OUTSIDE SCREW AND YOKE VAVLE ' <br /> AF45-22 TAMPER SPRINKLER VALVE E/4.8 — E506-2 1:19 MAN PULL COL. C-7 — 1E260 P PRESSURE TYPE <br /> PD PUMP DISCHARGE VALVE; PRESSURE TYPE W/DELAY <br /> AF45-24 TAMPER SPRINKLER VALVE E/4.8 — E506-2 1:32 MAN PULL COL. C-11 — 1E261 PH PENTHOUSE <br /> FIRE CANNON PNL FA E/5 — E506-2 2:13 MAN PULL COL. L-5 — 1E262 PW POST INDICATOR VALVE <br /> FIRE CANNON PNL TRBL E/5 — E506-2 1:12 FA FLAME COL. F-5.5 FIRE — 1E260 POWER FAIL FACP POWER FAILURE <br /> FIRE CANNON PNL SUPV E/5 — E506-2 1:13 TRBL FLAME COL. F-5.5 FAULT — tE260 PREACT PREACTION SYSTEM <br /> PRI PRIMARY REFERENCE DRAWINGS <br /> ELEV 24 FA E.5/2 — 1E260 1:15 SUPV FLAME COL. F-5.5 LW OR IR ONLY — 1E260 PS PUMP SUPPLY VALVE <br /> ELEV 24 TRBL E.5/2 — 1E260 1:16 MAN FLAME COL. F-5.5 MAN DISCH WITH AUX UV/IR TEST FUNC — 1E260 PWR POWER <br /> ELEV 24 SUPV E.5/2 — 1E260 1:20 FA FLAME COL. C-8 FIRE — 1E260 RF ROOF <br /> RLY RELAY <br /> 1:21 TRBL FLAME COL. C-8 FAULT — 1E260 SEC SECTION VALVE <br /> 1:23 SUPV FLAME COL C-8 W OR IR ONLY — 1E260 SHUNT SHUNT TRIP <br /> SMK SMOKE DETECTOR <br /> 1:25 FA FLAME COL. C-11 FIRE — 1E261 STL STALL <br /> 1:26 TRBL FLAME COL C-11 FAULT — 1E261 STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE <br /> 1:28 SUPV FLAME COL C-11 W OR IR ONLY — 1E261 SUPPR SUPPRESSION <br /> 1:29 MAN FLAME COL. C-11 MAN DISCH WITH AUX UV/IR TEST FUNC — 1E261 SUPV SUPERVISORY <br /> SV SPRINKLER VALVE <br /> 2:6 FA FLAME COL. L-5 FIRE — 1E262 TAMPER TAMPER SWITCH <br /> 2:7 TRBL FLAME COL. L-5 FAULT — 1E262 TL300 TL300 TYCO COMMUNICATION DEVICE <br /> 2:9 SUPV FLAME COL L-5 W OR IR ONLY — 1E262 TRBL TROUBLE <br /> 2:10 MAN FLAME COL L-5 MAN DISCH WITH AUX UV/IR TEST FUNC — 1E262 UV UNIT VALVE <br /> - VLV VALVE <br /> 2:14 FA FLAME COL P-8 FIRE — 1E264 WF WATERFLOW SWITCH <br /> 2:15 TRBL FLAME COL. P-8 FAULT — 1E264 ZN ZONE <br /> 2:17 SUPV FLAME COL P-8 W OR IR ONLY — 1E264 <br /> 2:19 FA FLAME COL P-11 FIRE — 1E265 *FOR POINTS LIST DESCRIPTORS <br /> 2:20 TRBL FLAME COL. P-11 FAULT — 1E265 CONSTRUCTION NOTES <br /> 2:22 SUPV FLAME COL. P-11 W OR IR ONLY — 1E265 <br /> 2:23 MAN FLAME COL. P-11 MAN DISCH WITH AUX W/IR.TEST FDNC — 1E265 <br /> BUILDING FACP POINTS LIST (#1-50) n FIRE CANNON FACP POINTS LIST (#1-50) <br /> SCALE: NONE E506 U SCALE: NONE E506 <br /> 600 Stewart St., Ste 1400 <br /> Seattle,Washington 98101 <br /> ISSUE FOR CONSTRUCTION 0 Tel 206.267.1700 <br /> OCTOBER 27,2017 Fax 206.267.1701 <br /> SAZAN#543-1741 <br /> SYM REVDION BY APPROVED 1 DATE SOB REVLSION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT RESYDON SYMBOL TE <br /> DA <br /> 70 00.30.16 FIRE ALARM SYSTEM - <br /> - EVERER ARE PANEL REPLACEMENT W2640474 SAZAN/Z0 10.27.17 THIS DESIGN AND/OR ZOLLKEA 09.30.16 DETAILS W2640474 10.27.17 <br /> Z)LA <br /> SPECIFICATION IS APPROVED SHEET OE/NG® SIN TT"E EVERETT FIRE PANEL REPLACEMENT E5OO 11„.. 7V,/,22.APPROVED BY DEPT. DATE 1(A 09.30.16 . <br /> CNECNED <br /> ROVED KA 09.30.16 BUILDING 45-003 JOB Np. W2640474 CoNO. <br /> APPROVED ELECTRICAL MASTER EVERETT, WA.D NO. 45-003—E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.