My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-03 2019-10-31
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-03
>
3003 W CASINO RD BLDG 45-03 2019-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2019 2:37:56 PM
Creation date
10/31/2019 2:37:07 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-03
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
*SPRINKLER VALVE WATERFLOW ALARM LEGEND <br /> MONITORING AND WATERFLOW ISOLATION <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION REFER TO SHEET El FOR SYMBOLS AND ABBREVIATIONS. <br /> n WATERFLOW REFER TO SHEET E506 FOR FIRE ALARM ABBREVIATIONS. <br /> ,-- - PRESSURE SWITCH I 6 <br /> WITH BUILT-IN <br /> RETARD/DELAY, I 5 <br /> POTTER#WFSR-F GENERAL NOTES <br /> ALARM I 12"X12" PHONE J-BOX <br /> FACP EVT-FA-45-03 FOR PRIMARY AND 1. ELECTRICAL CONTRACTOR SHALL INSTALL ENCLOSURE(S) <br /> I (BY FIRE ALARM VENDOR) SECONDARY PHONE PRIMARY CONNECTION:Q AND POWER. <br /> LINE JACKS PHONE LINE TO TELEPHONE <br /> I (BY ELECTRICAL BACKBOARD/ DEMARC. 2. WET RISER/PIPING CONFIGURATION SHOWN IS <br /> L— i TO WATER q — CONTRACTOR) (CABLING BY BOEING IT) DIAGRAMMATIC AND DOES NOT NECESSARILY REPRESENT <br /> ' / ) ANY SPECIFIC INSTALLATION. <br /> WATER PRESSURE GAUGE MOTOR GONG V <br /> (SYSTEM PRESSURE) / \ _ _ J I_————) \—SECONDARY CONNECTION:Q7 <br /> �// / �LARM LINE V WATERFLOW PHONE LINE TO TELEPHONE <br /> (OPEN) Y ISOLATION 4 ISOLATION I BACKBOARD/DEMARC. <br /> g,r_ C/I VALVE, I' TAMPER SWITCH, X Lj (CABLING BY BOEING IT) <br /> 00 /.� I APOLLO , POTTER #RBVS I <br /> BY-PASS LINE „ `\ L94A-103 27 (SUPERVISORY)� FIRE ALARM SYSTEM COMMUNICATIONS DETAIL n <br /> SCALE: NONE E506-1 <br /> - ---i <br /> CHECK VALVE t / o-,�\�\�� 'III - _ RETARD REFERENCE DRAWINGS <br /> \'*'', r` _ _ CHAMBER <br /> D IN <br /> WATER PRESSURE GAUGE , j •j//\I� CHECK RAI �./ VALVE <br /> (SUPPLY PRESSURE) OPEN / /! 111-1E1-11I <br /> �_�_.�. . J /� (CLOSED) <br /> OS&Y TAMPER „ _./2 ���—ISI la <br /> SWITCH WATER BY-PASS TEST <br /> ^ <br /> (SUPERVISORY)____,---- <br /> SUPERVISORY) VALVE (CLOSED) STRAINER DRIP <br /> noon <br /> ___rCUP CONSTRUCTION NOTES <br /> • <br /> --,`-_______---\ 1. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> WORKMANLIKE MANNER. <br /> 2. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> OS&Y VALVE <br /> CONTROL(OPEN) 3. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> CHECK <br /> VALVE 4. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL AND <br /> TELECOMMUNICATIONS ENCLOSURES SHALL BE IN <br /> ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br /> / - <br /> DRAIN S -PROVIDE PHENOLIC LABELS, INSTALL AND CENTER ON <br /> WATER SUPPLY PIPE UPPER ENCLOSURE DOOR WITH FACP AND POWER . <br /> CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> *NOTE: LETTERING AND RED BACKGROUND. <br /> LIMIT OF ONE(1) ISOLATION <br /> VALVE ON ALARM SENSING LINE. ©CONFIGURE FIRE ALARM CONTROL PANEL TO TRANSMIT <br /> PRIMARY AND SECONDARY COMMUNICATIONS IN A <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH W/DELAY DETAIL ( t SIMULTANEOUS MANNER IN ACCORDANCE WITH <br /> NFPA72-2016 26.6.4.1.4(8)(7). <br /> SCALE: NONE E506-1 <br /> 7 -PROVIDE CONDUIT WITH PULLSTRING. <br /> ®PROVIDE UNE SIZE BALL VALVE WITH LOCKABLE HANDLE, <br /> TYPE AS NOTED, ON ALARM LINE UPSTREAM OF ALARM <br /> SWITCH. <br /> E>PROVIDE TAMPER SWITCH, TYPE AS NOTED, ON ISOLATION <br /> VALVE AS SHOWN. PROVIDE CONNECTION TO NEW FIRE <br /> ALARM SYSTEM UTILIZING EXISTING INFRASTRUCTURE. <br /> PROVIDE ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> FIRE ALARM 7 ANALOG PHONE UNE (PRIMARY) REQUIRED. <br /> CON OL PANEL 1>PROVIDE WATERFLOW PRESSURE SWITCH WITH <br /> (FACP) *TELCO ADJUSTABLE DELAY,TYPE AS NOTED. PROVIDE CONNECTION <br /> I DEMARC • -MONITORED BY TYCO AND TO NEW FIRE ALARM SYSTEM UTILIZING EXISTING <br /> SIGNAL SENT TO CENTRAL INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT AND <br /> BOEING FIRE DEPARTMENT CONDUCTORS AS REQUIRED. <br /> --FIRE ALARM CABLING ANALOG PHONE LINE(SECONDARY) 11. CONFIRM ONLY ONE (1) ISOLATION VALVE IS INSTALLED ON <br /> WATERFLOW SENSING LINE. WHERE EXISTING INSTALLATIONS <br /> OS SMOKE DETECTOR, *TWO SEPARATE PATHWAYS FOR SIGNAL REQUIRED BY HAVE MORE THAN ONE (1)VALVE, COORDINATE REMOVAL <br /> PULL STATION, CODE,AS SHOWN. OF ADDITIONAL VALVE(S) WITH BOEING CONSTRUCTION <br /> WATER FLOW & MANAGER. <br /> TAMPER SWITCHES *BOEING SERVICES REQUEST MUST BE MADE <br /> REQUESTING:TWO ANALOG VOICE (BUSINESS FLAT LINE) 12. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR <br /> ®Q <br /> HORNS, BELLS JACK/CONNECTIONS.AFTER JACKS ARE INSTALLED, INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. <br /> & STROBES ANALOG LINES MUST BE REQUESTED TO CONNECT <br /> ANALOG VOICE JACKS. ' <br /> FIRE ALARM SYSTEM SIGNAL AND COMMUNICATIONS OVERVIEW 600 Stewart St., Ste 1400 <br /> SCALE: NONE E506-1 <br /> Seattle,Washington 98101 <br /> ISSUE FOR CONSTRUCTION Tel Tel 206.267.1700 <br /> OCTOBER 27,2017 Fax 206.267.1701 <br /> SAZAN#543-1741 <br /> SPA *0090* RE APPROVED RATE SON RFAS10N BY APPROMD OPE ACCEPTABILITY Z0 09.30.16 FIRE ALARM SYSTEM <br /> DRAWN DATE SUBDDE CURREM RENSION SYMBOL DALE <br /> - EVERE1T ARE PANEL REPLACEMENT #2640474 SAZAN/Z0 10.27.17 THIS DESIGN AND/OR CHEERIO <br /> #2640474 10 27.17 <br /> cel <br /> SPECIFICA71ON IS APPROVED ZO _ 09.30.16 DETAILS SHEE BOE,NC® ' F EVEREIT FIRE PANEL REPLACEMENT E506-1 (���a/ <br /> APPROVED BY DEPT. DATE CA 09.30.16 <br /> KA <br /> CHECKED <br /> ROVED 09.30.16 BUILDING 45-003 JOB NO. W2640474 co <br /> APPROVED ELECTRICAL MASTER EVERETT, WA.DNA ND' 45-003-E506-1 <br />