My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-03 2019-10-31
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-03
>
3003 W CASINO RD BLDG 45-03 2019-10-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/31/2019 2:37:56 PM
Creation date
10/31/2019 2:37:07 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-03
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> smE 4 SLC CIRCUIT FFF���\ O EQUIPMENT BOM - IFP PANELS #1 THRU #6 LEGEND <br /> T-TAPPING PERMUTED © 1 1 E (NP.) ' 1 WIRE NUT <br /> i 1 SPUCE ITEM QTY DESCRIPTION PART# MFG. <br /> SMOKE DETECTOR <br /> U- -- AIL" Li® 1 6 ENCLOSURE, 16 X 16 X 6, NEMA 4 A-16H16ALP HOFFMAN <br /> + i`2+_COM Z+COM i`2+COM 2 1-COM- RED +0-"' <br /> TO SLC - 3 INPUT 3 INPUT 3 INPUT SLACK-O—' 2 6 MTG. PANEL FOR ENCLOSURE A-16P16 HOFFMAN <br /> CIRCUIT I.SILL 4 CH 1 4 CH#1 GREEN 0 &I Y <br /> O le MSI-108 .•=•----75 _ - 5 _ �,5 — ORANGE ® 3 16 ADDRESSABLE INTERFACE DEVICE, 2 INPUT TRI-D SIEMENS <br /> X J MSI-208 E r� CHPp2�' A 6 / . <br /> USED e RELAY a ORANGE ® 4 6 ADDRESSABLE INTERFACE DEVICE, 1 INPUT, 1 RELAY TRI-R SIEMENS <br /> TRI-D 6 Y TRI-S TRI-R �rN TRI-B6M <br /> MANUAL STATIONI q�E E E-" 5 22 STD.4-SQUARE J-BOX, 2-1/8"D., 1/2&3/4"KO'S <br /> SMOKE DETECTOR (ADDRESSABLE) / / \ <br /> TYPICAL-ALL /--�•� EOLR O EOLR 111 O EOLR IJI.,I O/ , �� <br /> . \ 3.6K 3.6K " 3.6K Irl 36K I M , Q <br /> MONITORED SWITCHES ` Iii <br /> r _,- <br /> �_ I <br /> MONITORED SWITCH MONITORED WITCH MONITORED SWITCH <br /> (lEOLRFre===_ _=___=__ ___- -71 I 0 GENERAL NOTES <br /> 3.6K ,( V i SINGLE INPUT IFD SINGLE INPUT IFD SINGLE INPUT IFD I IIS _ ,II j' WITH RELAY COMPACT WiTH LEADS III ( II � Li�CONNECT SHIELD/DRAIN WIRES TOGETHER. DO <br /> II \®I \®1 II NOT CONNECT TO GROUND AT THIS LOCATION. <br /> DUAL INPUT IFD I U 7 II I INSULATE SHIELD/DRAIN TO PREVENT INCIDENTAL <br /> II I TRI-D TRI-D I. I le CONTACT WITH GROUND. <br /> TYPICAL DEVICE WIRING CONNECTIONS FOR ALL SLC CIRCUIT CONNECTIONS I II 40 "' I <br /> 81 Al <br /> II e2 0 e2 0_ I -1 <br /> III I I II 93 �6 e3 ea 001 <br /> 94 97 94 Q7 I <br /> I 95 66 85 B6 I <br /> SEE PLAN VIEWS NOTE: T-TAPPING NOT PERMITTED. CONDUCTORS II , I <br /> FOR WIRE SIZE MUST GO IN AND OUT OF EACH DEVICE. TRI-D MODULE OMITTED III I Min 0 ' I <br /> + ON IFP#2 AND IFP# I I I ' <br /> WIRE NUT 1 <br /> \'©� ,©� \4� EOLR DESIGN TED -- ummiummi SPUCE MANUAL STATION I F ® I <br /> TO NAC CIRCUIT � •j, <br /> CIRCUIT F- +• r;3'/ BACK BOX 11 i \ e 1 TRI-D 9 1 TRI-R I REFERENCE DRAWINGS <br /> FD DEVICE RED <br /> - <br /> (INSIDE BACK BOX) !BLACK-• 1© © 33 O 9 6 9 3 Ola 99 00 I <br /> 'GREEN 0l--N-4 I e a 8 7 g a e 7 <br /> NAC CIRCUIT TYPICAL WIRING IORANGE• III 11 e s e 6 e s e 6 1 <br /> I ORANGE• I r 1 I <br /> I II <br /> `TRI-B6M� ' 1 • l ® / I <br /> II I 1 <br /> NI a 120VAC CKT., DEDICATED III III _ II r® <br /> MANUAL STATION <br /> 3#12 NAP#1 III 011 ' ' I <br /> © (ON FRONT OF II \�J% \®�1 II <br /> 3.6KCL BACK BOX) � II I J 1 <br /> \ MULL=___ = U_IL j <br /> GINIH TB1 PAD3 OO ,�,� _� , I <br /> B'5?�I 12OVAC YFMP <br /> P & 0 4.- -,-,jnl <br /> BATT+O o <br /> BATT-O MANUAL STATION WITH <br /> . RESET - 3'O SEPARATE INTERNAL IFD MODULE <br /> N i ®i i 1 CONSTRUCTION NOTES <br /> _ <br /> 00111111 IFP PANEL ASSEMBLY — DETAIL(TYP) n CONNECT DEVICE TO NEW SIEMENS XLS FIRE CANNON <br /> CUT, <br /> OM <br /> OUR, [I] ALARM POIARAYSARAN SCALE: NONE E506-5` FIRE ALARM CONTROL PANEL IN FOAM ROOM. MAINTAIN <br /> Tun STO INPUT 1 INPUT 2 !NAC 1 INRC 2INAC 3INAC 41BOx PS EXISTING NOTIFICATION CIRCUIT CONTINUITY. SEE <br /> Arf11Q I+1- 1 LT I2+2-2 IrReL NC C NO + - + - + - + -+ - <br /> BATT 111 T62\````` ® SHEET E506-2. <br /> y340 000101€01SOSOI SEE PLAN VIEWS <br /> kgg FOR WIRE SIZE <br /> EOL v ALARM POLARITIES SHOWN <br /> 2.2Kn <br /> TO NAC CET. 1/4/- <br /> e l �� <br /> �} TO NAC CKT. 1/3/- 7 WIRE CODE (THIS SHEET ONLY): <br /> TO NAC CKT. 1/2/- DOWN, SEE / <br /> + // SHEET 1E262 I A= 2#16 TFN OR TFFN (STRANDED OR SOLID) <br /> B = 2#14 THHN (STRANDED) <br /> - -. TO NAC CKT. 1/1/- + i i "1 C = 2#12 THHN (STRANDED) <br /> +-�} D = 2#10 THHN (STRANDED) <br /> 3/4"C, 2#12 I�II ! E = #18 TWISTED SHIELDED PAIR (TSP), TYPE FPL OR CM <br /> Q\ <br /> N. <br /> +-,-FACP,MMB3,TB5-1 . �- 1/2/8 I I- t I! LOW CAPACITANCE CABLE (LESS THAN 3OpF/Fi) <br /> "-TI -- FACP,MMB3,TB5-4 30cd <br /> 0 tb,.EOLR CONTROL ROOM <br /> 1 � <br /> El � El _�BATTERY � BATTERY _ � -� __ - _ AI <br /> NOTIFICATION APPLIANCE DRIVER PANEL - , ---------I <br /> 600 Stewart St., Ste 1400 <br /> Seattle,Washington 98101 <br /> DEVICE WIRING DIAGRAMS r-j CONTROL ROOM PLANO ISSUE FOR CONSTRUCTION TelFax 206.267.1700206.267.1701 <br /> SCALE: NONE E506-5 SCALE: 1/4" 1' <br /> = -0" E506-5 N OCTOBER 27,2017 <br /> SAZAN#543-1741 <br /> SUM REV6TDN TA APPROVED DATE SAM REVISION NT APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL I DATE <br /> ACCEPTABILITY ZO 09.30.16 FIRE ALARM DETAILS- W2640474 - 1 1027 17 <br /> - EVERETTFlRE PANEL REPLACEMENT W2640474 SAZAN/ZO 10.27.17 THIS DESIGN AND/OR <br /> CHECKED 09.30.16 FIRE CANNON <br /> ZO SHEET <br /> SPECIFICATION IS APPROVEDwErN <br /> CHECKED 'ME /��al <br /> g)LARISPEZAIW' APPROVED a DEPT. DATE KR 09.30.16 EVERETT FIRE PANEL REPLACEMENT E506-5 <br /> KA 0930.16 BUILDING 45-003 -JONO. COMP <br /> APPROVED W2640474 <br /> APPROVED ELECTRICAL MASTER EVERETT, WA.DWG NO' 45-003-E506-5 <br />