Laserfiche WebLink
NTROL <br /> STROBE STROBE ,..►t�1 ROOM <br /> ONLY ONLY <br /> C C C C C EDLR G(NAC 1/2/-) C (NAC 1/2/-) LEGEND <br /> D (NAC 1/4/-) <br /> • <br /> hlwp PI yip (?'�IWp IN . RIwp (N WP 4, (NAC 1/2/-) <br /> • A A A A A E(SLC1) <br /> HANGAR 1/4/6 1/4/5 1/4/4 1/4/3 1/4/2 1/4/1 ' <br /> EAST SIDE EOLR B(24VDC) STAIR 381 <br /> B(24VDC) B(24VDC) <br /> B(SV2) D (NAC 1/4/-) E (BCCI) m AURA <br /> B(24VDC) B(SV4) B(SV4) C (NAC 1/2/-) ❑F ONLY GENERAL NOTES <br /> B(SV4) E(SLC2) 5EEE(SLC2)E(SLC2) D (NAC 1/4/-) <br /> :9 <br /> E(SLC2) + + ,, 1/2/7 ) <br /> B(SV4)-�� /-E(IFD) 3E 2B(24VDC) (SLC2 1. RISER IS DIAGRAMMATIC AND DOES NOT <br /> / REPRESENT ACTUAL INSTALLATION. <br /> 2B(24VDC �SE 1/2/6 D® 2. FIRE ALARM SYSTEM: <br /> 3E E(SLC2) ) r2B(24VDC) B(SV3) E (SLC1) (NAG 1/3/-) SIGNAL LINE CIRCUIT SLC <br /> 1 C (NAC 1/2/-) (SLC) <br /> B(24VDC) 9 ^ n B(24VDC) B(24VDC) D (NAG 1/4/-)� I <br /> (SLC1) DEVICE ADDRESSING LEGEND <br /> E At IFP#6 5E IFPS `i' E IFP#4 `�' E(SLC2) <br /> ® 14 ® ® - ® ® B(SV3) HANGAR LL RM. AURA 1:5 <br /> © © 2:19,20 2:21,22 2:14,15 2:16,17 © © 2:6,7 2:8,9 B(SV4) SOUTH SIDE E (SLC1) ONLY <br /> Ems, ® 17 ® E Ems, 1;1 ® —. E(SLC2) C (NAC 1/2/—) m �eP ©Ep SLC CIRCUITS) DEVICE ADDRESS <br /> Q 2:24,25 2:23 2:18 Q 2:11.12 2:10 o/-E(IFD) C (NAG 1/3/—) 1:8 <br /> ®SV4 MANUAL - ; MANUAL 1/2/5 ExE3/1 (SLC1) NOTIFICATION OLR MICE ADDRESSING LEGENDPPLIANCE CIRCUIT() <br /> WPO DISCH. F 13 1 SV3 WP©DISCH. _ / <br /> STROBE 1 / 1 /7 <br /> ONLY ORIGIN PNL.) T Z <br /> EAST AFT MONITOR. STATION EAST MID UV/IR FLAME DETECTOR EAST FWD MONITOR STATION J DEVICE q <br /> (SLC1) (SLC1) NAC CKT# <br /> C(NAC 1/2/-) C (NAC 1/2/-) �� E (SLC1) <br /> C(NAC 1/3/-) C (NAC 1/3/-) <br /> 1/2/4WP <br /> C (NAG (/2/-) WIRE CODE (THIS SHEET ONLY): <br /> STROBE STROBE STROBE D(NAG 1/4/-) D (NAG 1/4/-) <br /> 4/ ) C (NAG 1/3/-) <br /> B ONLY B B ONLY B ONLY D (NAG 1/4/-) <br /> HANGAR 1=1 Iii (�) I�1 (�) B (y • (i( ly A= 2#i6 TFN OR TFFN (STRANDED OR SOLID) <br /> WEST SIDE wP WP WP wP Wp - wP WP B = 2#14 THHN (STRANDED) <br /> /a B(24VDC) 1/A • A B(24VDC) A A/ • • 1/2/3 A C = 2412 THHN (STRANDED) <br /> B(SV2) B(24VDC) <br /> B(24VDC) 1/1/3 B(24VDC)1/1/2 B(SV1) 1/1/1 1 2/1 1/2/2 WEST <br /> B(SV2) B(SV2 STAIR'B' D = 2410 THHN (STRANDED) <br /> [E(SLC1) EOLR E(SLC1) B(SV2) E(SLCt) B(SV2) E(SLC1)— RM 141 1:7 E = #18 TWISTED SHIELDED PAIR (TSP), <br /> O a ) O 5E` E(SLC1) O O sE E(SLC1) O ( )� 5 B B7 TYPE CABLE(LESL SRCM LOW THAN 30pF/FT)CITANCE <br /> 2B(24VDC) 5 ��1, A/2/2 <br /> B(SV2)._....,___. /{ 3E 2B(24VDC) Q _ — _ — — - B, <br /> A E(SLC1) \ 2B 24VDC t 5E I A/2/1 �® _ _ _ <br /> r ( ) I I I STROBE EOLR <br /> 5E B SV1 2B� OUTSIDE ABV. <br /> 3E--,,,, (1�6(24VDC) (� , B(24VDC) ��`/ v v v ✓ MECHRM <br /> E FP/3 Y 5E m►2 `( E FP91 `f E(SLC1) 1 — REFERENCE DRAWINGS <br /> © © 12®6 1:27,28 1:22®1 1:22,23 © © 1:1®31:®15 <br /> /�-E(SLC1) E EI FIRE CANNON 45-03 GUIDING FM p-, KIM VS AFFF MAIN MN TANKS MD TAMPER r--->SEE SHEET E506-7 FOR BUILDING FIRE ALARM <br /> / E ® ® ® E----"' ® ® FIRE ALARM "ma wo.i FIRE ALARM 1, X:XX VS AFFF MAIN VLV TAMPER CONTROL PANEL SYSTEM RISER. <br /> ❑ 1:30,31 1:29 1:24 O �-L 1:17,181:16 /'E(IFD) I CONTROL PANEL CONTROL PANEL ANNUNCIATOR %.X VS C/D MIN VLV TAMPER <br /> ,...filli <br /> NP MANUAL --- d // (FACP) (FACP) X:XX VS FOAM VLV TANK D TAMPER <br /> 01:32 © WPO DISCH. F 1:19 <br /> OE \ 0:%%VS WATER VLV TANK C TAMPER <br /> MANUAL 3 12 I 1 / X:XX VS WATER VLV TANK D TAMPER I O <br /> SV1 W©DISCH. 4 [MODEL <br /> l r SIEMENS l kARMCINLY <br /> ❑F 1'6 - <br /> 120VAC ca., L MODEL%LS J L MODEL zLs J <br /> WEST AFT MONITOR STATION WEST MID UV/IR FLAME DETECTOR WEST FWD MONITOR STATION DEDICATED MECH RM CONSTRUCTION NOTES <br /> 144 DR. <br /> I B� 1. SEE SHEET E506-2 FOR CONSTRUCTION INSTRUCTIONS. <br /> &1T 1— 1 O <br /> L_ MECH RM 144 (FOAM ROOM) <br /> J FIRST(GROUND)FLOOR <br /> FIRE CANNON SYSTEM RISER DIAGRAM 1:5 SMK ® FACP COL. E-5 1:21 TRBL FLAME COL. C-8 2:10 MAN FLAME COL. L-5 X:XX AFFF MAIN VLV TANKS A-D TAMPER <br /> SCALE: NONE E506-6 1:6 MAN PULL COL. D-4 1:23 SUPV FLAME COL. C-8 2:11 UV45-24D TAMPER X:XX AFFF MAIN VLV TAMPER <br /> 1:7 MAN PULL COL. E-2 1:25 FA FLAME COL. C-11 2:12 AF45-24D TAMPER X:XX C/D MAIN VLV TAMPER <br /> 1:8 MAN PULL COL. J-0 1:26 TRBL FLAME COL. C-11 2:13 MAN PULL COL. L-5 X:XX FOAM VLV TANK D TAMPER <br /> 1:9 MAN PULL COL. L-1 1:27 UV45-24B WF 2:14 FA FLAME COL. P-8 X:XX WATER VLV TANK C TAMPER <br /> 1:12 FA FLAME COL. F-5.5 1:28 SUPV FLAME COL. C-11 2:15 TRBL FLAME COL. P-B X:XX WATER VLV TANK D TAMPER <br /> NAP1 FM 1:13 TRBL FLAME COL. F-5.5 1:29 MAN FLAME COL. C-11 2:17 SUPV FLAME COL. P-8 <br /> FIRE ALARM 96"MAX.TO TOP OF 1:14 UV45-24A WF 1:30 0145-24B TAMPER 2:19 FA FLAME COL. P-11 <br /> CONTROL PANEL NAC DRNER PNL ANNUNCIATOR DEVICE <br /> (FAGP) (EXISTING) (PREFERRED MTG. HEIGHT) 1:15 SUPV FLAME COL. F-5.5 1:31 AF45-24B TAMPER 2:20 TRBL FLAME COL. P-11 <br /> I 1:16 MAN FLAME COL. F-5.5 1:32 MAN PULL COL. C-11 2:21 UV45-24C WF <br /> 4" 80" MIN.TO 1:17 UV45-24A TAMPER _ 2:6 FA FLAME COL. L-5 2:22 SUPV FLAME COL. P-11 <br /> r SIEMENS l T BOTTOM OF DEVICE 1:18 AF45-24A TAMPER 2:7 TRBL FLAME COL. L-5 2:23 MAN FLAME COL. P-11 <br /> L MODEL XLS J <br /> 1APS :19 MAN PULL COL. C-7 2:8 W45-24D WF 2:24 UV45-24C TAMPER <br /> 70" AUX.PIVFL SUPPLY 70" <br /> l 1 1:20 FA FLAME COL. C-8 2:9 SUPV FLAME COL. L-5 2:25 AF45-24C TAMPER <br /> 4. <br /> —� I 06-6 <br /> BAT �T 48 s IREJDCANNON RISER POINTS LIST* (FOR REF. ONLY) Es(-3.- <br /> --f-- <br /> *SEE SHEET E506 FOR COMPLETE POINTS LIST <br /> 600 Stewart St., Ste 1400 <br /> Seattle,Washington 98101 <br /> EQUIPMENT MOUNTING ELEVATIONS � ISSUE FOR CONSTRUCTION 0 Tel 206.267.1700 <br /> E506-6 <br /> SCALE: NONE OCTOBER 27,2017 Fax 206.267.1701 <br /> SAZAN#543-1741 <br /> SYM REVISION DY APPROVED I DATE 5YM REWSION BY APPROVED DATE <br /> DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> - EVERETT FIRE PANEL REPLACEMENT W2640474 SATAN/Z0 10.27.17 ACCEPTABILITYNAND/OR <br /> ZO 09.30.16 FIRE ALARM DETAILS- — <br /> THIS DESIGN DHECKED W2640474 10.217 <br /> gLA <br /> SPECIFICATION IS APPROVED 20 09.30.16 FIRE CANNON SHEET )OE/AVG® APP D BY DEPT' D"� w`IEH09.30.16 REEVERETT FIRE PANEL REPLACEMENT (��'CHECKED E506-6 <br /> D <br /> ROVED 09.30.16 BUILDING 45-003 JOB N0. COMP NV—. <br /> W2640474 <br /> APPROV°' ELECTRICAL MASTER EVERETT,WA.DOG N0. 45-003-E506-6 <br />