My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 COLUMBIA AVE 2019-11-01
>
Address Records
>
COLUMBIA AVE
>
2201
>
2201 COLUMBIA AVE 2019-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2019 8:28:33 AM
Creation date
11/1/2019 8:27:23 AM
Metadata
Fields
Template:
Address Document
Street Name
COLUMBIA AVE
Street Number
2201
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MODULE SPECIFICATION DC CONDUCTOR AMPACITY CALCULATIONS <br /> MANUFACTURER ITEK ENERGY ARRAY TO JUNCTION BOX(CEC ART 310.15) <br /> A EXPECTED WIRE TEMPERATURE(FREE AIR) 30 CELSIUS <br /> MODEL NO. IT-300-SEB ADD 22°C OR 40°F FOR CONDUITS EXPOSED TO 52 CELSIUS <br /> PEAK POWER 300W SUNLIGHT ON OR ABOVE ROOF <br /> TEMPERATURE CORRECTION FACTOR <br /> RATED VOLTAGE(VMP) 32.9 V CEC TABLE 310.15(B)(2)(A) 0.76 <br /> RATED CURRENT(IMP) 9.0 A C #OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) <br /> .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br /> D CONDUIT FILL CORRECTION 0.80 <br /> OPEN CIRCUIT VOLTAGE(Voc) 39.8 V CEC TABLE 310.15(B)(3)(A) Smart energy today <br /> SHORT CIRCUIT CURRENT(Isc) 9.7 A E CIRCUIT CONDUCTOR SIZE #10 AWG <br /> F CIRCUIT CONDUCTOR AMPACITY 40 AMPS CEC TABLE 310.15(B)(16) <br /> G REQUIRED CIRCUIT CONDUCTOR AMPACITY 15 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY=MAXIMUM OPTIMIZER OUTPUT CURRENT(AMPS)(FROM OPTIMIZERS <br /> OPTIMIZERS SPECIFICATION SPECIFICATIONS) <br /> H DERATED AMPACITY OF CIRCUIT CONDUCTOR 24.32 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY SOLAR <br /> MAKE SOLAREDGE P320CEC TABLE 310.15(B)(2)(A) <br /> MAXIMUM INPUT DC POWER 320 NOTE:"H"MUST BE LARGER THAN"G" 24.32A > 1 5A=OK •y, <br /> ABSOLUTE MAX INPUT VOLTAGE(VOC) 48 VDC DC CONDUCTOR AMPACITY CALCULATIONS �i11y1y \ <br /> MAX SHORT CIRCUIT CURRENT(ISC) 11 ADC COMBINER/JUNCTION BOX TO INVERTER <br /> MAX DC INPUT CURRENT 13.75 ADC (ADD 22°OR 40°FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) 1001 COOPER POINT <br /> A AMBIENT TEMPERATURE ADJUSTMENT 52 CELSIUS CEC TABLE 310.15(B)(2)(A)&CEC TABLE 310.15(B)(2)(C) RD SW,STE 140-290, <br /> MAX OUTPUT CURRENT 15 ADC EXPOSED CONDUIT OLYMPIA,WA 98502 <br /> EXPECTED WIRE TEMPERATURE <br /> PHONE:360-637-4343 <br /> MAX OUTPUT VOLTAGE 60 ADC TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15(B)(2)(A) <br /> #OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) HEIDI PASCHAL <br /> CONDUIT FILL CORRECTION 0.80 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) PROJECT MANAGER <br /> INVERTER SPECIFICATION CEC TABLE 310.15(B)(3)(A) <br /> CIRCUIT CONDUCTOR SIZE #10 AWG <br /> INVERTER MAKE SOLAREDGE CIRCUIT CONDUCTOR AMPACITY 40 AMPS CEC TABLE 310.15(B)(16) <br /> INVERTER MODEL NO. SE7600H-US B REQUIRED CIRCUIT CONDUCTOR AMPACITY 20.0 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY=MAXIMUM INVERTER INPUT CURRENT(AMPS)(FROM INVERTER MANUFACTURER 9.000 DC KW <br /> SPECIFICATIONS) <br /> MAX INPUT VOLTAGE 480 V7.600 KW CEC-AC RATING <br /> C DERATED AMPACITY OF CIRCUIT CONDUCTOR 30.72 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br /> MAX INPUT CURRENT 20.0 A CEC TABLE 310.15(B)(2)(A) CENTRAL INVERTER SYSTEM <br /> NOMIMAL AC VOLTAGE 240 V NOTE:"C"MUST BE LARGER THAN"B" 30.72A >20.00A=OK 23° 90°, 180°,270° <br /> MAX AC CURRENT 32.OA AC CONDUCTOR AMPACITY CALCULATIONS TILT AZIMUTH <br /> INVERTER TO MAIN SERVICE <br /> AMBIENT TEMPERATURE ADJUSTMENT (ADD 22°OR 40°FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) <br /> LOCATION INFORMATION A EXPOSED CONDUIT 52 CELSIUS CEC TABLE 310.15(B)(2)(A)&CEC TABLE 310.15(B)(2)(C) 2201 COLUMBIA AN E <br /> EXPECTED WIRE TEMPERATURE <br /> HIGH TEMP 33° TEMPERATURE CORRECTION FACTOR 0.96 CEC TABLE 310.15(B)(2)(A) EVERETT, <br /> LOW TEMP -4° #OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) WA 98203 <br /> CONDUIT FILL CORRECTION 1.00 .80(FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00(FOR 3 OR LESS CONDUCTORS IN CONDUIT) <br /> VOLTAGE CORRECTION FACTOR 1.12CEC TABLE 310.15(B)(3)(A) ANNA HAALA <br /> ROOF TEMP 55° CIRCUIT CONDUCTOR SIZE #6 AWG (206)321-9355 <br /> CIRCUIT CONDUCTOR AMPACITY @ 90° 75.0 AMPS CEC TABLE 310.15(B)(16) <br /> TEMP CORRECTION FACTOR(ROOF TEMP) 0.76 INVERTER'S MAXIMUM AC OUTPUT CURRENT 32.0 AMPS INVERTER MANUFACTURER SPECIFICATIONS <br /> TEMP CORRECTION FACTOR(HIGH TEMP) 0.96 B REQUIRED AC CONDUCTOR AMPACITY 40.00 AMPS REQUIRED AC CONDUCTOR AMPACITY=1.25 X MAXIMUM INVERTER'S OUTPUT CURRENT(AMPS) APN:00545001701700 <br /> C DERATED AMPACITY OF CIRCUIT CONDUCTORS 72.00 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY <br /> CEC TABLE 310.15(B)(2)(A) <br /> NOTE:"C"MUST BE GREATER THAN"B" 72.00A >40.00A=OK <br /> DATE DESCRIPTION <br /> DATE 1/14/19 <br /> DRAWN: <br /> DRAWN BY: PD <br /> ELECTRICAL <br /> CALCULATIONS <br /> E - 2 (..,,,,D <br />
The URL can be used to link to this page
Your browser does not support the video tag.