My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 COLUMBIA AVE 2019-11-01
>
Address Records
>
COLUMBIA AVE
>
2201
>
2201 COLUMBIA AVE 2019-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2019 8:28:33 AM
Creation date
11/1/2019 8:27:23 AM
Metadata
Fields
Template:
Address Document
Street Name
COLUMBIA AVE
Street Number
2201
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> NET METER <br /> / f <br /> UTILITY/AHJ(PHENOLIC) 1 1. /,---Th, 1\ ,:. <br /> /, <br /> _ <br /> I I <br /> I POWER TO THIS BUILDING IS SUPPLIED FROM THE <br /> NEC 705.12(6)(3) FOLLOWING SOURCES WITH DISCONNECT LOCATED AS SHOWN <br /> N <br /> PHOTOVOLTAIC - .Smart energy today' <br /> TURN OFF PHOTOVOLTAIC r i <br /> lal AC DISCONNECT PRIOR TO H - t.,, <br /> .. . WORKING INSIDE PANEL <br /> AC DISCONNECT .. W <br /> ii 'ii NEC 110.21(B)&NEC 705.12 VIf,f11,‘ <br /> NEC 690.13(B) !MI !II ' <br /> I■ ,1■II1 I 1001 COOPER POINT <br /> I RD SW,STE 140-290. <br /> ,■ ,■ <br /> 1 i _ 0 OLYMPIA,WA 98502 <br /> ��1.!I <br /> WARNING NEC 705.12(6)(3) ii j PHONE:360-637-4343 <br /> HEIDI PASCHAL <br /> SUPPLY J`+IDE TAP PROJECT MANAGER <br /> INVERTER OUTPUT CONNECTION.DO AC DISCONNECT PROJECT DETAILS <br /> AS REQUIRED IF PV ! PRODUCTION METER <br /> NOT RELOCATE / <br /> THIS OVERCURRENT INTERCONNECTION IS NET METER S 9.000 DC KW <br /> DEVICE. MADE TO SUPPLY SIDE OF <br /> 7.600 KW CEC-AC RATING <br /> NEC 705.12(B)(2)(3)(b) SERVICE DISCONNECT CENTRAL INVERTER SYSTEM <br /> 23° 90°, 180°,270° <br /> PRODUCTION METER TILT AZIMUTH <br /> PRODUCTION METER SERVICED BY QUALIFIED PERSONNEL ONLY CUSTOMER INFO <br /> UTILITY/AHJ(PHENOLIC) I 1 NEC 690.53 2201 COLUMBIA ANE <br /> WARNING PHOTOVOLTAIC DC DISCONNECT EVERETT, <br /> , I WARNING DUAL POWF„RSOUI(.'E I OPERATING VOLTAGE 400 v WA 98203 <br /> "' "" OPERATING CIRCUIT CURRENT 20.0 A <br /> MAXIMUM VOLTAGE 480 V ANNA HAALA <br /> NEC 705.12(6)(3) MAXIMUM CIRCUIT CURRENT 30.0 A (206)321-9355 <br /> NEC 690.56 ADHESIVE FASTENED SIGNS: <br /> •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. APN:00545001701700 <br /> PHOTOVOLTAIC SYSTEM •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS, <br /> SOLAR PV SYSTEM EQUIPPED I AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(B)FIELD MARKING]. <br /> WITH RAPID SHUTDOWN -� °", EQUIPPED WITH •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS <br /> 2 ,: M RAPID SHUTDOWN SHALL BE WEATHER RESISTANT[IFC 605.1 1.1.3] REVISION <br /> TURN RAPID SHUTDOWN ... IDATE DESCRIPTION <br /> SWITCH TO THE 'a;A`,,, ", `'� J °"�""�"" NEC 690.31 G 3 & 4 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS ' <br /> "OFF"POSITION TO `� ®' APPLICATION. <br /> T SHUTDOWN PV SYSTEM ''""`'"-' WARNING: PHOTOVOLTAIC 2.) ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600 V AND 90 DEGREE C WET <br /> AND REDUCE :. <br /> SHOCK HAZARD <br /> tl WATCH FOR POWER SOURCE ENVIRONMENT. <br /> IN THE ARRAY SOLAR PVSYSTEM 3.) WIRING.CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED <br /> DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP, <br /> NEC 690.56(C)(1)(a) OR VALLEY. DATE 1/14/19 <br /> 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT DRAWN: <br /> PHOTOVOLTAIC AC DISCONNECT SHALL COMPLY WITH NEC 110.26. PD <br /> MAXIfIUMACOPERATING CURRENT 32.0A e 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR DRAWN BY: <br /> MAXIMUM AC OPERATING VOLTAGE 240 VAC SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACCESSORIES SHEETTITLE <br /> TO FULFILL APPLICABLE CODES AND STANDARDS. <br /> NEC 690.54 6.) WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED, <br /> THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br /> 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. LABELING <br /> /� WARNING A ARNIN , 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND REQUIREMENT <br /> A „VV RAPID SHUTDOWN INSTRUCTION.SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S UE <br /> ELECTRIC SHOCK HAZARD WARNING: PHOTOVOLTAIC <br /> DO NOT TOUCH TERMINALS SWITCH FOR 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB <br /> TERMINALS ON BOTH LINE AND POWER SOURCE LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br /> LOAD SIDES MAY BE ENERGIZED SOLAR PV SYSTEM 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE SHEET NUMBER <br /> _ IN THE OPEN POSITION NEC 690.56(C)(3) NEC 690.31(G)(3)&(4) <br /> NEC 690.13(6)&NEC 690.115(D) SYSTEM DC CIRCUIT CONDUCTORS.EXPOSED RACEWAYS,CABLE TRAYS&OTHER WIRING <br /> METHODS.COVERS OR ENCLOSURES OF PULL BOXES&JUNCTION BOXES.CONDUIT BODIES IN <br /> WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. <br /> LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION.REFLECTIVE WITH X'UPPERCASE, E - 3E <br /> „4//z- <br /> , <br /> WHITE ON RED.EVERY SECTION OF THE WIRING SYSTEM SEPARATED BY ENCLOSURES,WALLS, I <br /> PARTITIONS,CEILINGS,OR FLOORS.SPACING BETWEEN LABELS OR MARKINGS SHALL NOT BE <br /> MORE THAN 10' <br />
The URL can be used to link to this page
Your browser does not support the video tag.