My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3001 OAKES AVE 2017 Plans 2022-11-23
>
Address Records
>
OAKES AVE
>
3001
>
Plans
>
3001 OAKES AVE 2017 Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 2:09:44 PM
Creation date
11/6/2019 10:55:31 AM
Metadata
Fields
Template:
Address Document
Street Name
OAKES AVE
Street Number
3001
Permit
B1709-011
Year
2017
Notes
RESTORATION OF EXTG INTERIOR WALLS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� � � ' CARN EGI E <br /> . <br /> S Ms MOTOR STARTER � U I L�D I N G ` <br /> M r F T ELECTRONICAI.LY COMMUTA7ED <br /> SUI'PLY ��M MOTER R E S TO R A T10 N � <br /> EXHAUST AIR � � AIR <br /> � �� A`��"" 3n�1 �AKE� AVE. . � <br /> A�S AIRFLOW MEASURING STATION EVEF�ETT, WA 98201 <br /> Ec� B�s BUILDING PRESSURE SENSOR ' <br /> GAS FURNACE <br /> SUPPLY FAN <br /> Pl�4TE AND FRAME �s CUF�RENT SENSOR � <br /> HEAT EXCHANGER �' <br /> �:� <br /> oPs DIFFERENTIAL PRESSUf�E SWITCH �+ <br /> ECM � <br /> psa DUCT' 5MOKE DETECTOR � <br /> R � <br /> M DP M DP T F t FZ ) �REEZESTAT � � <br /> _pF' �.o�� <br /> OUTSIDE AIR � � E�X�HAUST wuis HIGH LIMI�f HUMIDITY SENSOR CC� <br /> E� � � <br /> FILTER � � , m DB �ILTER . <br /> .� <br /> EXHAUST FAN �►�s HIGH LIMIT PRESSURE SWITCH <br /> � <br /> Hs HUMIDITY SENSOR � �:; <br /> "z vFD HER�z 2813 ROCKEFELLER AVE ' ' <br /> LLHS LOW LIMIT HUMIDITY SENSOR EVERETT, WA 9�201 <br /> NOTES: PHONE: 425.317.8017 . <br /> �.LPs LOW LIMIT PRESSURE SWITCH FAX: 425.317.�4�9 <br /> 1. HX FACE AND BYPASS D,�MPERS (DF AND D�) LOCAI'ED WIl'HIN THE AHU. <br /> 2. ALL (5) DAMPER ACTUATORS �Y THE CONTROLS CONTRACTOR. �� MOTOR OPERATED DAMPER . <br /> sc VFD SPEED CON7ROL <br /> �: <br /> sPs STATIC PRESSURE SENSOR , <br /> ,. . <br /> 1 1 �f�i �I � I /`�� V 1 �1 l� � � �/� l�i C "�, ss 5TART STOP <br /> M7.1 SCALE: NQNE <br /> � <br /> � TEMF'ERA`fURE TRANSMITfER , ' <br /> SEQUENGE OF OPERATION <br /> NO NORMALLY OpEN <br /> A. GENERAL: <br /> 1. SYSTEMS IS CONSTANT VOLUME WITH GAS FURNACE. NC NORMALLY CLOSED <br /> 2. SYSTEM PROVIDES TEMPERED VENTILATION AIR FOR THE LOWER LEVEL OF THE BUILDING. <br /> 3. SUPPLY RND EXHAUST FAN MOTORS ARE CONTROLLED BY ELECTRONICALLY COMMUTATED MOTORS (ECM). FAN STATUS IS MONITORED THROUGH CURRENT SENSORS IN THE MOTOR ,'���� ��� <br /> STARTERS. ` <br /> 4. AN ALARM IS ENERGIZED UPON FAILURE OF ANY DEVICE. �",�, ��. <br /> 5. ALL SETPOINTS AND SCHEDULES SHALL BE ADJUSTABLE. � ; �� ' - <br /> �'�"- �° <br /> B. SYSTEM START/STOP: � � <br /> ���i,1 ,�'' , <br /> 1. PROGRAMMED SCHEDULING: AIR HANDLING SYSTEM RUNS ACCORDING TO THE OWNER PROVIDED SCHEDULE. � � <br /> 2. THE DDC SYSTEM SHALL ENABLE AND DISABLE THE AHU FANS AND SHALL PROVIDE START/STOP AND SPEED CONTROL FOR EACH ECM. CONTROL SYSTEM SHALL MONITOR THE ���� �+� <br /> FOLLOWING INPUTS THROUGH EACH ECM: HERTZ, STATUS, AND FAULT ALARM. <br /> 3. UNIT START: UN17 STARTS ACCORDING TO THE OWNER PROVIDED SCHEDULE. �� . <br /> 4. NORMAL SHUTDOWN: DAMPERS SHALL BE !N THE FOLLOWING POSITIONS WHEN UNIT IS OFF FOR ANY REA50N: <br /> a. OUTDOOR AIR DAMPER: CLOSED. <br /> b. EXHAUST AIR DAMPER: CLOSED. <br /> c. HEATING: OFF. �- <br /> 5. SAFETY SHUTDOWN: <br /> a. FIRE ALARM: THE AIR HANDLING UNIT SHUTS DOWN UPON RECEIPT OF FIRE DETECTION SIGNAL FROM THE DDC SYSTEM. DDC SHALL RESTART SYSTEM UPON RECEIPT OF AN "ALL EXHAUST FAN SCHEDULED (EF-� � y <br /> CLEAR" SIGNAL FROM THE FIRE ALARM SYSTEM. � <br /> C. AHU DISCHARGE AIR TEMPERATURE CONTROL: THE HEAT EXCHANGER (HX) FACE AND BYPASS DAMPERS AND 2-STAGE GAS FURNACE ARE CONTROLLED IN SEQUENCE (HX PRIMARY, GAS HEAT SYSTEM DESCRIPTION: " <br /> SECONDARY)TO MAINTAIN THE DISCHARGE AIR TEMPERATURE (DAT) SETPOINT; INITIAL SETPOINT IS 70 F. DIRECT DRIVE EXHAUST FAN PROVIDES BUILDING EXHAUST, arm REqSTERED ' <br /> �RCHITECT <br /> D. FAN SPEED CONTROL: THE SUPPLY AND EXHAUST FAN SPEEDS SHALL BE CONTROLLED BY THE DDC SYSTEM THRU THE RESPECTIVE ECMS TO MAfNTAIN CONSTANT AIR VOL.UME (TO OFFSET MODES OF OPERATION: <br /> FILTER LOADING). BUILDING MANAGEMENT SYSTEM SHALL CONTROL OCCUPIED OR UNOCCUPIED MODE BASED ON A USER <br /> DEFINABLE SCHEDULE. SANDRA J. ALDEI2 ' <br /> STA'iE OF Wd�iiTON <br /> E. FREEZE PROTECTION: FREEZE STAT SHALL BE INTERLOCKED WITH THE FACE AND BYPASS DAMPER OPERATION TO ALLOW MORE RETURN AIR TO BYPASS THE HEAT EXCHANGER TO PREVENT <br /> THE EXHAUST AIR FROM DROPPING TO ADJ. LOW TEMP LIMIT; INITIAL EXHAUST AIR LIMIT SETPOINT IS 32 F. THE BUILDING MANAGEMENT SYSTEM CONTROLS MAY BE OVERRIDDEN BY THE FIRE ALARM SYSTEM. <br /> �F UNOCCUPIED MODE: � <br /> EXHAUST AIR � EXHAUST AIR EXHAUST FAN: FAN IS OFF. <br /> EXHAUST DAMPER: DAMPER IS CLOSED. SCALE: AS NOTED i <br /> M M <br /> MS OCCUPIED MODE: I�SUE DATE: O��Z��ZO77 <br /> EXHAUST FAN: FAN IS ON. DRAWN: AC <br /> POINT DESIGNATION DIGITAL DIGITAL ANALOG ANALOG ALARMS REMARKS CS SS EXHAUST DAMPER: DAMPER IS OPEN. ' <br /> OUTPUT INPUT OUTPUT i►vPu-r �HECKED: RE <br /> DOAS AIR HANDLING UNIT, WITH HEAT REC�VERY ALARMS: <br /> EXHAUST FAN: <br /> SUPPLY FAN START/STOP FE 1 • FAN FAILURE: COMMANDED ON, BUT THE STATUS IS OFF. (,� TNIS PLAN AND DESIGN IS AND REPIAAINS <br /> • FAN IN HAND: COMMANDED OFF, BUT THE STATUS IS ON. TWE PROPERTY OF THE ARCHITECTS AND <br /> SUPPLY FAN STATUS FS 1 PROVIDE CURRENT SENSING RELAY MAY NOl' �E USED VNTMOUT PRIOR <br /> SUPPLY FAN VOLUME AFS 1 PROVIDE AIR FLOW SENSOR FAILURE MODE: CONSENT FROM THE ARCHII�CT <br /> IN THE EVENT OF A FIRE ALARM INPUT, THE SYSTEM COMPONENTS SHOULD BE COMMANDED AS FOLLOWS: " <br /> RETURN FAN START/STOP FE 1 EXHAUST FAN: FAN IS OFF. <br /> RETURN FAN STATUS FS 1 PROVIDE CURRENT SENSING RELAY REVIEW <br /> RETURN FAN VOLUME AFR 1 PROVIDE AIR FLOW SENSOR <br /> SUPPLY AIR TEMPERATURE TS 1 2 ���,���� �d�� �����Vl� �I�1,�d�01� ����1) • <br /> REV. DATE DE�CRIPTION - <br /> RETURN AIR TEMPERATURE TR 1 M��� SCALE: NONE <br /> OUTSIDE AIR DAMPER COMMAND DO 1 OrJ 26 SCHEMATIC �ESIGN <br /> EXHAUST AIR DAMPER COMMAND DE 1 O8 1 �J PROGRESS D�AWINGS . <br /> HX FACE DAMPER COMMAND DF 1 O9 O� PERMIT SET <br /> HX BYPASS DAMPER COMMAND DB 1 POINT DESIGNATION DIGITAL DIGITAL ANALOG ANALOG ALARMS REMARKS <br /> GAS FURNACE CONTROL - 1ST STAGE GF1 1 OUTPUT INPUT OUTPUT INPUT " <br /> GAS FURNACE CONTROL -2ND STAGE GF2 1 EXHAUST FAN, SCHEDULED (EF-1) <br /> GAS FURNACE STATUS GFS 1 PROVIDE CURRENT SENSING RELAY EXHAUST FAN START/STOP SS 1 <br /> FILTER DIFFERENTIAL PRESSURE DP 2 2 EXHAUST FAN PROOF CS 1 1 CURRENT SENSING RELAY <br /> FRE�ZE PROTECTION FZ 1 INTERLOCK WITH FACE & BYPASS DAMPER CONTROL MOTORIZED DAMPER DE 1 • <br /> GENERAL NOTES: M E��l /�N I �f'1L ��� TR�LS <br /> 1. PROVIDE ADDITIONAL DDC INPUT/OUTPUT POINTS AND ALARMS WEHERE REQUIRED IN ORDER TO COMPLY WITH THE SEQUENCE OF OPERATIONS. GENERAL NOTES: D 1 AGR/`'iM S <br /> 2. SEE SEQUENCE OF OPERATION FOR ADDITIONAL ALARMS. 1. PROVIDE ADDITIONAL DDC INPUT/OUTPUT POINTS AND ALARMS WEHERE REQUIRED IN ORDER TC7 COMPLY WITH THE SEQUENCE OF OPERATIONS. <br /> 3. PROVIDE GRAPHICS FOR ALL POINTS. Z. PROVIDE GRAPHICS FOR ALL POINTS. <br /> <: <br /> • <br /> E:' <br />
The URL can be used to link to this page
Your browser does not support the video tag.