Laserfiche WebLink
_____ _ _ . . ___. __ . ,� <br /> O <br /> � �oMM� oA W C A R N E G I E <br /> o SETISORATURE <br /> DO QAMPER B U I L D I I V G <br /> M M <br /> DL DAMPER ROOFTOP AIR MOD DE DAMPER R E S T 0 R A T I 0 N <br /> HANDUNG UNIT � <br /> R1U-1 NC . <br /> R�,-2 �' �' `� `� 3001 OAKES AVE. <br /> � <br /> RTU-3 DR DAMPER � <br /> BUILDWG � � <br /> RELlEF AIR RN-4 ; E VE R E T , WA 9 2 01 <br /> MOD � TM CS <br /> � GAS-FlRED FURNACE CONDENSING COIL EXNAUST FAN <br /> i n � SUPPLY FAN Z EF-t MS <br /> 1 �- c� ------- --� 4 SS <br /> i---- ------�--- - � ---- Q --- � � � a <br /> � jR � j$ INTERLOCK TO OPERATE WITH <br /> �� MS � � AHUS �{ <br /> FlLTER COOLING COII � � <br /> i CS SS i � O , <br /> � � COMPRESSOR SEC110N � � <br /> � � � <br /> � j w <br /> � ALL WIRING FOR A COMPLETE <br /> � SYSTEM(SHOWN AND NOT <br /> r� <br /> ( SHOWN)BY CONTROLS � <br /> i CONTRACTOR(TYP) � <br /> GAS j ��^ � <br /> I i�i <br /> I � <br /> � U <br /> , . <br /> � <br /> � <br /> � <br /> ' Rn � sA 2813 ROCKEFELLER AVE <br /> � EVERETT, WA 98201 <br /> � -------- OS ZONE OCCUPANCY <br /> i �---------------------- sENSOR PHONE: 425.317.8017 <br /> EFOANI D T RM NA�LC NITO(TYP) H AHU, ' ( FAX: 425.J�7.�4G79 <br /> I � �---------------------1 <br /> 1 I � <br /> � I PROVIDE WIRELESS <br /> I ( � j SENSORS <br /> LOCATE IN MECH/ELEC ROOM � ( � I) <br /> � � � I <br /> 1 <br /> 1 <br /> JCI BMS I <br /> CONTROL ROOM <br /> PANELAND 'n' TEMPERATURE <br /> DISPLAY SENSORS <br /> � ROOFI'OP AIR HANDLING SYSTEM AIRFLOW AND CONTR�L DIAGRAM CRTU-1, 2, 3 AND 4) <br /> M�.2 SCALE: NONE <br /> �� ��� <br /> �'�,, <br /> �� � <br /> , <br /> � •� <br /> �� <br /> SEQUENCE OF OPERATION ����� � <br /> s �_. . <br /> A. GENERAL: POINT DESIGNATION DIGITAL DIGITAL ANALOG ANALOG ALARMS REMARKS �� �,'� <br /> OUTPUT INPUT OUTPUT INPUT <br /> 1. SYSTEMS ARE CONSTANT VOLUME. PACKAGED ROOFTOP AIR CONDITIONER WITH GAS HEAT, 4 TYP. � �� <br /> 2. SYSTEMS PROVIDE HEATING, COOLING AND VENTILATION FOR THE BUILDING. <br /> 3. SUPPLY AND EXHAUST FAN MOTORS ARE DIRECT DRIVE. FAN STATUS IS MONITORED THROUGH SUPPLY FAN START/STOP SS 4 <br /> CURRENT SENSORS IN THE MOTOR STARTERS. SUPPLY FAN STATUS CS 4 4 PROVIDE CURRENT SENSING RELAY <br /> 4. AN ALARM IS ENERGIZED UPON FAILURE OF ANY DEVICE. SUPPLY AIR TEMPERATURE TS 4 <br /> 5. ALL SETPOINTS AND SCHEDULES SHALL BE ADJUSTABLE <br /> RETURN AIR TEMPERATURE TR 4 <br /> B. SYSTEM START/STOP: MIXED AIR TEMPERATURE TM 1 <br /> 1. PROGRAMMED SCHEDULING: AIR HANDLING SYSTEM RUNS ACCORDING TO THE OWNER PROVIDED OUTSIDE AIR DAMPER COMMAND DO 4 <br /> SCHEDULE. RETURN AIR DAMPER COMMAND DR 4 ARCHIIECT <br /> sno R q <br /> 2. THE BUILDING MANAGEMENT SYSTEM (BMS) SHALL ENABLE AND DISABLE THE SYS7EM AND SHALL RELIEF AIR DAMPER DL 1 <br /> PROVIDE START/STOP FOR EACH RTU. <br /> 3. INTERLOCKWG IS PROGRAMMED AS FOLLOWS: OCCUPANCY SENSOR OS 4 SMIDRA J. AL.DER <br /> a. EXHAUST FAN RUNS WHEN THE RTUS RUN UNLESS NOTED OTHERWISE. sr��°F w�a�°N <br /> OUTSIDE AIR MONITOR AF 4 <br /> 4. UNIT START: PROVIDE OPTIMAL START, MORNING WARM-UP, AND MORNING COOL-DOWN <br /> SEQUENCES. WARM-UP AND COOL-DOWN BY THE AHUS IN FULL RECIRCULATION MODE. ROOM THERMOSTAT RT 4 <br /> 5. NORMAL SHUTDOWN: DAMPERS SHALL BE IN THE FOLLOWING POSITIONS WHEN UNIT IS OFF FOR <br /> ANY REASON: <br /> a. OUTDOOR AIR DAMPER: CLOSED. GENERAL NOTES: <br /> b. RETURN AIR DAMPER: OPEN. 1. PROVIDE ADDITIONAL DDC INPUT/OUTPUT POINTS AND ALARMS WEHER� REQUIRED IN ORDER TO COMPLY WITH THE SEQUENCE OF OPERATIONS. SCALE: AS NOTED <br /> c. RELIEF AIR DAMPER (BUILDING): CLOSED. 2. PROVIDE SAFETY CIRCUIT FOR FAN SHUTDOWN AND TO BREAK POWER TO VALVE AND DAMPER ACTUATORS. SAFTEY CIRCUIT SHALL BE ROUTED THROUGH FREEZESTATS, HIGH STATIC ISSUE DATE: O��Z4�ZO�7 <br /> d. EXHAUST DAMPER (EF): CLOSED. PRESSURE SWITCHES AND SMOKE DUCT DETECTORS. PROVIDE RELAY'S AS REQUIRED FOR FAN SHUTDOWN AT STARTERNFD. DRAWN: AC <br /> e. DX COOLING: OFF. CHECKED: RE <br /> f. HEATING: OFF. 3. SEE SEQUENCE OF OPERATION FOR ADDITIONAL ALARMS. <br /> 5. SAFETY SHUTDOWN: 4. PROVIDE GRAPHICS FOR ALL POINTS. <br /> a. FIRE ALARM: RTUS SHALL SHUT DOWN ON SIGNAL FROM TNE FIRE ALARM SYSTEM. BMS SHALL THIS PLAN AND DESIGN IS AND REMAINS <br /> RESTART SYSTEM UPON RECEIPT OF AN "ALL CLEAR" SIGNAL FROM THE FIRE ALARM SYSTEM. 5. REFER TO AHU SCHEDULES FOR MULTIPLE VFDS FOR SUPPLY & RETURN FAN ARRAYS. �THE PROPERTY OF THE ARCHITECTS AND <br /> C. AHU DISCHARGE AIR TEMPERATURE CONTROL: MAY NOT BE USED WITHOUT PRIOR <br /> NOTES: CONSENT FROM THE ARCHITECT <br /> 1. THE ECONOMIZER DAMPER AND DX COOLING SYSTEM ARE CONTROLLED IN SEQUENCE TO MAINTAIN 1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. <br /> THE DISCHARGE AIR TEMPERATURE (DAT) SETPOINT; INITIAL SETPOINT IS 56 F. THE SYSTEM SHALL <br /> RUN A QUERY EVERY 10 MINUTES TO DETERMINE WHETHER THE SETPOINT SHOULD BE INCREASED REVIEW , <br /> OR DECREASED. DAT SHALL BE RESET BETWEEN 52F AND 60F AS DESCRBED BELOW. <br /> 2. DECREASE DAT-IF THE ASSOCIATED ZONE TEMPERATURE IS 2F OR MORE ABOVE SETPOINT THEN REV. DATE DESCRIPTION <br /> DECREASE THE DAT BY 1 F. <br /> 3. INCREASE DAT-IF THE ASSOCIATED ZONE TEMPERATURE IS 2F OR MORE ABOVE SETPOINT THEN O�'J ZC SCHEMATIC DESIGN <br /> WCREASE THE DAT BY 1 F. <br /> 4. DURING HEATING, THE ECONOMIZER DAMPERS ARE POSITIONED TO MWfMUM OUTDOOR AIR. DURING O8 � 'rJ" PROGRESS DRAWINGS <br /> COOLING, THE ECONOMIZER DAMPERS AND DX COOLWG ARE CONTROLLED IN SEQUENCE TO MEET <br /> THE COOLfNG REQUIREMENT. O9 OS PERMIT SET <br /> 5. ENABLE THE ECONOMIZER WHEN THE OUTSIDE AIR TEMPERATURE IS LESS THEN OR EQUAL TO THE � <br /> RETURN AIR TEMPERATURE MINUS 2F. DISABLE THE ECONOMIZER WHEN THE OUTSIDE AIR <br /> TEMPERATURE IS GREATER THEN OR EQUAL TO THE RETURN AIR TEMPERATURE PLUS 2F. <br /> D. MINIMUM OUTDOOR AIR: FLOW IS MAINTAINED AT A CONSTANT VALUE BY MODULATION OF THE OUTDOOR <br /> AIR DAMPER. MINIMUM OUTDOOR AIRFLOW SETPOINT IS (NDICATED ON THE EQUIPMENT SCHEDULES. � <br /> E. ZONE TEMPERATURE CONTROL <br /> 1. ZONE TEMPERATURE SETPOINTS SHALL BE 70F FOR HEATING AND 75F FOR COOLING DURING M ECH AN I CAL LEGEN D O(. <br /> OCCUPIED TIME PERIODS AND 60F FOR HEATING AND 85F FOR COOLING DURING UNOCCUPIED TIME <br /> PERIODS FOR ENERGY SAVINGS. RESET ALL UNOCCUPIED SETPOINTS TO OCCUPIED SO ZONE IS UP GEN ER AL N OTES <br /> TO TEMPERATURE PRIOR TO OCCUPANCY. <br /> G. EXHAUST FAN: THE TWO POSITION CONTROL DAMPER SHALL OPEN FULLY PRIOR TO FAN START-UP. <br /> H. BUILDING RELIEF AIR DAMPER: SHALL BE INTERLOCKED WITH THE RTU OPERATION. DAMPER IS OPEN <br /> WHEN ANY RTU IS IN OCCUPIED MODE AND CLOSED WHEN THE RTUS ARE IN UNOCCUPIED, MORNING <br /> WARMUP OR COOLDOWN MODES. � <br /> • <br /> � <br />