My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3927 RUCKER AVE 2018 Plans 2022-12-02
>
Address Records
>
RUCKER AVE
>
3927
>
Plans
>
3927 RUCKER AVE 2018 Plans 2022-12-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2022 10:37:34 AM
Creation date
11/6/2019 11:43:19 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Permit
B1804-013
Year
2018
Notes
REPLACE BLDG CLADDING EXTEND EXISTING ADD NEW ENTRY CANPOY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> :� i ���3�� ��������� <br /> . � M �� � �� � �� � � � � � � <br /> 193'-6" <br /> 27'-6„ <br /> 18'-6" 30'- 0" 30'-0" 30'-0" 30'- 0" 27'-6" <br /> I <br /> A2-02 <br /> � i I I I Paint existing conc <br /> I I I MRI condensing units � retaining wall at loading <br /> � dock <br /> � <br /> � Canopy-pn-11 � , ,/� ' '� ; ����j";� � � <br /> � � <br /> �� /; � � �� MRI Coolant lines- <br /> � � Paint � �- paint ��%���� � ';������j � � I � I �5 � <br /> �� � � <br /> �, <br /> ��� � ecast pre � � . �� F <br /> � , __�____._.�_____. � �� �� _.�..____._. <br /> , , . �� _ �.._�_ __�_ �_.� <br /> _._ _. �..._ _ <br /> � __.____ _._._____.�.�___ _ _��:_ �.�,-�_ - <br /> _� ��_ .__d�._��____-____.�_�.__ ,��_.___� ...�.�.�____��. __..__.._ w-� ��- _ _ _ _ <br /> � - , - - - - - - - - Eg <br /> precast recast <br /> i <br /> I � I I � I I I Paint existing loading dock <br /> *PROJECT NOTES-un � walls,soffit, Doors and G u N D E RS O N � <br /> Drainage-pn-8 I <br /> rames w ere existing <br /> � EIFS remains to match <br /> 1. Remove e�asting coping-install new coping and snap lock new IFS color. B U 1 L D 1 N G <br /> I I � I j flashing per detail-typical at all sides of the building unless noted I I I I � <br /> � otherwise � <br /> 0o i 2. � Area of reduced parapet height(5"approximate clr ht)apply new � <br /> ' ' coping per detail � <br /> N i 3. Existing coping at entry curtain wall glazing to remain-tie to new � � R E C LA D <br /> coping per detail � _ <br /> � I I � I 4. I Low roof beyond-prep and install new roof overlay-material to I I I I <br /> i match existing system-verify carlisle epdm with decorative <br /> ; � ballast,coping and associated wall flashings per details 3927 Rucker Ave Everett Wa <br /> 5. Existing entry canopy beyond-basic scope-remove existing > > <br /> ; I , Kalwall and store for re-use.As necessary to install the new __ � BASIC WORK-EIFS CLADDING : <br /> wark-Cut and remove 1 ex isting sloped frame against the <br /> I I I ( I exterior wall-Re-assemble and reinstall following cladding work. I �.-_ I � I <br /> I --�� A. Remove existing cladding(including stone plinths <br /> i _ _ _ _ _ _ � � Substitute new AEP span Select seam narrow batten roofing_ �_ _ _ _ _as several locations around the building.) and _ _ _ _ _ D 4 <br /> ' panels for existing corrugated metal roofing panels _,� 3 sheathing to expose existing framing and 6"batt �•� <br /> �I, � 6. New sloped sill-AEP Span flush metal or Select Seam Narrow � � insulation. j <br /> � Batten panels-carry tight to e�erior wall(with windows)tuck - B -. � .�� �� B. Install new 5/8"Dens Glas Gold sheathing and <br /> ' 5��� below existing window sill flashing-e�end as necessary.Carry � � - � A , I <br /> � I � ,� �/� ;t approved wet applied wrb materials(same as at <br /> projected sill across intermediate columns at contiguous recessed � _ _--_ �, `� eifs) <br /> I window conditions-Continuous head flashing at the top of � .� ��� C. Instal1 new AEP Span Select Seam standing seam <br /> contiguous window recesses placed at intersection of soffit and i � : f � metal anel claddin -assume 20"wide anels, <br /> ; g ( furthest exterior wall. Typical at all recessed window locations. � p �_ � '� � � g p <br /> ` , centered-run continuous across all conti�quous <br /> � ; 7. E�sting bus stop-temporarily remove exisiting railing- reinstall i � � � window recesses. <br /> ' � following completion of the work in that area. Coordinate with '�-- g g � , I . ' <br /> ; N � � � I � �� � i �.; D. Install new Dryvit Outsulation MD system in ( <br /> N Community Transit. - � � thicknesses noted on the drawin gs- <br /> ! 8. j Excavate along builidng-6-12"down 8"min from bldg- place � ' �' i � � � Refer to Dryvit details OPMD 0,0,01,02 <br /> j retaining mtls per detail,drain pipe and drain rock to maintain ,,; , � • <br /> I se aration from bottom of claddin to rade.Tie to e�stin ��' ; ` -�-.: I ; i ; and 06/A3-02 for typical manufacturer's <br /> ! A2-02 2 �recast � � footing drain-Alternately provide g2"diameter drywell 2'deep in � � E ' { � assulme two finish colors- I � A2-01 <br /> I I I landscaping.Det 02/A3-01.b � � � � Install precast concrete accent panels at i 0 4 2 5 1 8 <br /> a. Minor adjustment of existing grade at building to create the three building entrances as indicated. <br /> drainage swale at area indicated to the south side of the For Construction <br /> precast building. <br /> � — — 9. Typica�recladdin work below existing curtain wall element. — — — — — �� <br /> I 10. i coo ' es a ensi � to r ' pera 'onal � BASIC RECLADDING WORK ' <br /> � � during all construetio activities. lash existin sheet met cover � 1/4" — 1'-0° � ' I � <br /> `� precast with new sheet metal flashing per detail 04/A3-01 b <br /> �; Canopy-pn-5 — precast 11. Temporarily remove exisitng canvas canopy at 1st flr East si e- I i <br /> N Reinstall at completion of work I ; ��� �����-�E��� � <br /> � � 12 Sign Location-confirm location of mounting points for the �_ _ "EIFS"NOTE _ _ _ _ _ _ _� _ <br /> � precast � — — — — -e�asting sign to be reinstalled-coordinate with owner. Trea — — — — — C5 �,R'������T <br /> � � I � � mounting points in conformance with Dryvit details. � Use of the EIFS label on these drawings relates directly to the I � � <br /> 13. Own t onfirm 'ment s� e d rou ening r ' ed for specified Dryvit system:Outsulation Plus MD System. The details f <br /> � ceme . Ver t wall ' g is fr to this contained on sheets A3-02,A3-03 and A3-04 are the manufacturer's �t <br /> Sill- � <br /> N 1 criteria, and modify as required to conform if not.This minimally standard details for a wide range of conditions that exist at the <br /> � \ pn-16 requires a head track at the top and double studs at the jambs of Gunderson building. These details illustrate the typical application � <br /> , \ � — 1� I the required opening. and installation requirements for the specified product. Other project <br /> � � � 14. � Continuous metal flashing at transition from 4"to 2"rigid � specific details or scope notes that may conflict with the requirements I I -�iJ��,..P� �. �LLE(� <br /> \ � insulation aligned with the bottom sill condition of the first floor � of these standard details will be brought to the attention of the , ����� ����������� <br /> � windows. Typical-refer to detail A3-01 a ! Architect for clarification and resolution. ; <br /> �,`� 15 Contino eal ali ith the ashing �ions at ' <br /> �` �'` � reces o the 2n n rd floo e detail 0 - 1 a _ _ _ _ _ _ _ _ _ _ _ _ _ �� <br /> `��F y�� 16. Paint concrete sidewalls and rails at level landing to e�tisting <br /> � o md � I � ( I garage and the curved connecting stair. I � EIFS NOTE I I I <br /> 0 0.09 17. � P int all exteri r hollow met I doors in are s of new EIFS to � „ _ , „ <br /> I N � � tch ne colors i a1 1/4 1 -0 , <br /> � <br /> o A3-02 1� � *Project notes are referenced from multiple drawings in this <br /> , drain track option I drawing set. <br /> � � at conc/asphalt <br /> I I I I I <br /> I I I <br /> pn-16 i rev-1 - tlate- topic addendum 1 -05 09 18 <br /> � � � rev-2 - da#e- topic <br /> - - - - - - - - - i - - - -�-- - - - - - - ; - - - - - B4 <br /> � <br /> I I I I I I � rev-3-date- topic <br /> �'� - ' I � rev-4-da#e- topic � <br /> �, � <br /> ��� � <br /> � � � rev-5- date- topic <br /> � M <br /> � � I I I I � I I I I <br /> rev-6 -date- topic � <br /> I I I I <br /> � — — — — — — — — — — — — — — — — — — — — <br /> � � - -�— - - - A7 <br /> � i i i i i i i <br /> ! o � <br /> , �- � o, j <br /> '� a, � � 3-01 i <br /> I T <br /> �' I I I I I I I I I I <br /> I <br /> - - - - - - - - - A1 . <br /> ! i � i � i ! � <br /> , <br /> � <br /> � <br /> ; <br /> ; <br /> i i i i i �� i <br /> I . <br /> $ 7 6 5 4 3 2 � F I RST F LOO R P LAN <br /> 2 <br /> A2-01 <br /> � <br /> � LEVEL 1 <br /> � �is�� _ ��-o�� EVOLUTION <br /> ARCHITECTURE - INC <br /> 6264 ELLIS AVE S � <br /> Seattle, Washington, <br /> ph 206 588 <br /> info@evolutionarchitecture.net <br />
The URL can be used to link to this page
Your browser does not support the video tag.