Laserfiche WebLink
a <br /> Interior Lighting - Building Area Method LTG-INT-BLD <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Carnegie Building Restoration Date 9/11/2017 <br /> Calculation o o Addition- o Addition For Building Department Use <br /> Area"°TE8 staid alone +existing <br /> o Spaces where<50%of ® Spaces where>_50%of o <br /> luminaires are replaced luminaires are replaced <br /> LPA ® Standard O Additional Efficiency Package Option o <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> lnebteticcosp404533e4MdtlitlroviiirremitierhiltRikshall be 25%lower than the Target LPA. <br /> Type <br /> Maximum Allowed Lighting Wattage NOTE <br /> Location(plan#, 1 Gross Interior Allowed Watts Allowed <br /> Building Area room#,or ALL) Area Description Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Office ALL General Use 9000 0.66 5940 <br /> Total 9000 1 <br /> Proposed Lighting Wattage <br /> Location(plan#, Number of Watts per <br /> Building Area room#) Fixture Description NOTE 2,3,4,5 Fixtures Fixture NOTE 6 Watts Proposed <br /> OFFICE ALL L1 2X4 LAY IN 72 32 2304 <br /> OFFICE ALL L2 1X4 PENDANT 6 24 144 <br /> OFFICE ALL P1 LED PENDANT 6 50 300 <br /> OFFICE ALL C1 RECESSEDDOWNLIGHT 38 15 570 <br /> OFFICE ALL Fl STRIP LIGHT 32 32 1024 <br /> OFFICE ALL W1 VANITY LED 4 31 124 <br /> OFFICE ALL X1 EXIT 2 <br /> Compliance by Building Area"°'h' <br /> Total Allowed Total Proposed Interior Lighting <br /> Building Area Warnings Watts Watts Power Allowance <br /> Office 5940 4466 COMPLIES <br /> Confirm all fixtures are reported under proposed lighting-low watts <br /> relative to maximum allowed. <br /> Note 1-List all unique building areas per Table C405.4.2(1)that occur in the Totals 5940 I 4466 <br /> project scope. Select building area category from drop down menu. <br /> Note 2-Proposed fixtures must be listed in the building area in which they occur.List all proposed lighting fixtures including exempt <br /> lighting equipment and existing-to-remah fixtures. <br /> Note 3-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included). <br /> For track fighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 4-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 5-Existing-to-remah fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as <br /> existing in fixture description. <br /> Note 6-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-h lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting, enter the wattage of the transformer. For fine voltage track/busway systems,enter the larger of the attached luminaire wattage or <br />